Protec Warm Roof Systems - Cold-Applied Liquid Membrane

Verified by manufacturer 3 months ago

Warm Roof (Polyroof Approved Timber Overlay)

Polyroof Products Ltd Variant:
Third party certifications:
  • BBA Agrément Certificate

    BBA Agrément Certificate

    Certificate type

  • European Technical Approval (ETA)

    European Technical Approval (ETA)

    Certificate type

  • EPD

    EPD

    Certificate type

  • ISO 9001 Quality Management

    Certificate type

  • UK Technical Assessment (UKTA)

    UK Technical Assessment (UKTA)

    Certificate type

A range of warm roof systems with a cold-applied liquid membrane finish.

Jump to:
BOS
+44 (0)1352 735135 Website

Application

Suitable for flat and pitched roofs, balconies, terraces and walkway applications.

Description

Protec is a highly versatile, fast curing, fully reinforced cold liquid applied membrane system, suitable for a wide range of roofing and waterproofing applications.


The Protec RapidCure technology utilizes catalyst, accelerators and inhibitors allowing full control over cure times across a wide range of temperatures all year round. The seamless Protec membrane features the optimum combination of flexibility and toughness, making it suitable for roofs, terraces and walkways of all sizes including situations requiring regular foot traffic. Where new insulation is required, the Protec Warm Roof System can be specified as a flat or tapered scheme to provide a highly efficient solution and meet the very highest thermal performance requirements. Protec offers lasting weatherproof protection for at least 30 years (BBA Cert. No. 09/4676) and is supported by Polyroof’s Approved System Guarantees for up to 25 years.


Features and benefits:

  • Flexible and tough membrane - A flexible hybrid polymer waterproofing system with flexibility and robustness. 
  • RapidCure Technology - Fast application with cure times as low as 30 minutes. Cured state is tough, seamless and impermeable.
  • Seamless waterproof membrane - Applied as a liquid, Protec forms a seamless waterproof membrane with no joints, no welds and no weak points. 
  • Cold applied installation with zero risks from hot works - Unlike many traditional roofing materials that require open flame hot works to install, Protec is fully cold applied meaning there are no risks of accidental fire during installation. 
  • Fire performance - Classified as BROOF(t4), the top rating achievable for a flat roof system and designating Protec as unrestricted under the national requirements. 
  • Protec is BBA Certified(Cert No. 09/4676) with a certified lifespan of at least 30 years. Protec is also FM Approved, UKTA Certified (UKTA-0836-22/6389) and ETA Certified (ETA-20/0914) with CE marking. 
  • Suitable for use with zero falls in accordance with BBA certificate BBA (09/4676).
  • Manufactured in accordance with BS EN ISO 9001:2015 and BS EN 14001:2015.
  • Protec waterproofing membrane has a third party verified, product specific EPD to EN 15804:2012+A2:2019.


Please consult Polyroof Products Ltd for further specification advice.

General information

Color

Grey

Other

Guidance for specification option:

Bespoke / Specials available, consult manufacturer for details.

Finish

Smooth

Guidance for specification option:

Seamless, watertight finish.

Material

Polymer

Guidance for specification option:

Flexible hybrid polymer

Polyisocyanurate (PIR)

Expanded polystyrene (EPS)

Stonewool

Shape

Other

Length

Bespoke

Manufacturer guidance

Please refer to project specific drawings. Formed on site.

Width

Bespoke

Manufacturer guidance

Please refer to project specific drawings. Formed on site.

Height

Bespoke

Manufacturer guidance

Variable - dependent upon thermal performance requirement.

Warranty description

20 year

Guidance for specification option:

As standard.

25 year

Guidance for specification option:

Subject to specification and discussions with Polyroof Products Ltd.

Uniclass

Ss_30_40_30_43 Liquid-applied warm roof covering systemsPrimary

CAWS

J31/10 Warm deck roof coating

J31/120 Warm deck roof coating

Specification data - Liquid-applied warm roof covering systems

Preparation

-

Horizontal work

-

Manufacturer guidance

Please consult Polyroof for guidance and insert requirements.

Skirtings and vertical work

-

Manufacturer guidance

Please consult Polyroof for guidance and insert requirements.

Air and vapour control layer

Visqueen (1000 gauge).

Polyroof SA Vapour Control Layer.

Guidance for specification option:

With Polyroof SA Primer.

Insulation

-

Type

Polyroof Foil Therm Insulation.

Guidance for specification option:

Thickness dependent upon U-value requirement.

Fixing

Mechanically Fixed. Dependant upon Wind Loading Calculation Data (BS EN 1991 – 1-4:2005 (Eurocode 1)).

Overlay

-

Type

18 mm Polyroof approved plywood.

Guidance for specification option:

Primed with catalysed Uni-Primer DP.

18 mm Polyroof approved OSB3 (TG4).

Guidance for specification option:

Primed with catalysed Uni-Primer DP.

Manufacturer guidance

Overlay to insulation.

Carrier membrane

-

Type

Not required for this system.

Liquid-applied waterproofing

-

Type

Cold Liquid Applied Protec Resin with catalyst (two coats).

Reinforcement

Polymat 450 (first coat).

Surface treatment

None.

Paving (with pedestals).

Decking (with pedestals).

Polyroof Anti-slip (Quartz Sand and PolyFinish) – Regular Traffic.

Guidance for specification option:

Following clients request, third coat of Cold Liquid Applied Protec Resin. Broadcast in Quartz Sand, PolyFinish Sealer Coat. For further guidance, consult manufacturer.

Polyroof Anti-slip (Mineral Slate) – Maintenance Traffic.

Guidance for specification option:

Following clients request, third coat of Cold Liquid Applied Protec Resin. Broadcast in Mineral Slate. For further guidance, consult manufacturer.

Polyroof Anti-slip (ProGrip) – Maintenance Traffic.

Guidance for specification option:

Following clients request, one coat of ProGrip Anti-Slip Coating. For further guidance, consult manufacturer.

Polyroof Anti-slip (ProGrip and PolyFinish) – Regular Traffic.

Guidance for specification option:

Following clients request, one coat of ProGrip Anti-Slip Coating. PolyFinish Sealer Coat. For further guidance, consult manufacturer.

System accessories

None.

Polyroof pre-formed GRP Trims - drip/ upstand.

Polyroof pre-formed GRP Trims - fillet.

Polyroof pre-formed GRP Trims - termination bar

Polyroof pre-formed GRP Trims - simulated metal finish - standing seam.

Polyroof pre-formed GRP Trims - simulated metal finish - lead roll.

Polyroof pre-formed Internal Outlets.

Polyroof pre-formed Through Wall Outlets.

Polyroof Fall Arrest Systems.

Round Lightning Conductor Clip.

Polyroof Fixing Plates (for PV cells / Balustrade systems).

Polyroof PR Rooflights.

Fixings - EJOT TKR, associated stress plates and plastic tube washers.

Fixings - EJOT TKE, associated stress plates and plastic tube washers.

Fixings - EJOT FBS, associated stress plates and plastic tube washers.

Fixings - EJOT FPS, associated stress plates and plastic tube washers.

Polyroof GRP Expansion Trims.

Execution

Installation by Polyroof approved contractors.

Colour

Light Grey.

Chromite Grey.

Quartz Grey.

RAL specials.

BS specials.

Fire performance

Achieves Broof T4 classification in accordance with BBA certificate (09/4676).

Cure time

30–60 minutes.

Application temperature

3–30°C.

Guidance for specification option:

The system can be installed down as low as 1°C deck temperature with the addition of Product Accelerators.

Substrate

Concrete.

Structural Metal Roof Deck.

Timber.

Fall

Flat.

Pitched.

Flat and pitched.

Third-party certification

BBA Certificate Number 09/4676.
Third party verified, product specific EPD (EN 15804:2012+A2:2019) - BREG EN EPD No.: 000516.

Slip resistance

Tested to BS 7976-2: 2002.

Resistance to water penetration

Suitable for use with zero falls in accordance with BBA certificate (09/4676).

Sustainability data

Country of material origin

United Kingdom

Country of product manufacture

United Kingdom

Material

Polymer

Guidance for specification option:

Flexible hybrid polymer

Polyisocyanurate (PIR)

Expanded polystyrene (EPS)

Stonewool

Third party certifications

BIM objects

BOS

NBS BIM Object Standard

This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.

Find out more about the NBS BIM Object Standard.

Platform Compatible Version
Revit
-

1

IFC
-

1

Third party certifications

BBA Agrément Certificate

BBA Agrément Certificate

Protec System BBA Certificate

European Technical Approval (ETA)

European Technical Approval (ETA)

Protec System ETA

EPD

EPD

BREG EN EPD 000516

ISO 9001 Quality Management

ISO 9001 Quality Management

Polyroof ISO 9001 Certificate

UK Technical Assessment (UKTA)

UK Technical Assessment (UKTA)

UK Technical Assessment Protec (UKTA-0836-22/6398)

Literature

Polyroof Seamless Waterproofing Solutions

Polyroof Seamless Waterproofing Solutions

Modular Construction Solutions

Modular Construction Solutions

Green Roof Addition Sheet - Protec

Green Roof Addition Sheet - Protec

System TDS Protec System

System TDS Protec System

Protec Declaration of Performance

Protec Declaration of Performance

Outline Specification - PR20201 Protec Balcony Warm Roof Refurbishment (Adhesively Bonded Insulation)

Outline Specification - PR20201 Protec Balcony Warm Roof Refurbishment (Adhesively Bonded Insulation)

Outline Specification - PR20205 Protec Warm Roof Refurbishment (Polyroof VIP Insulation and Carrier Layer)

Outline Specification - PR20205 Protec Warm Roof Refurbishment (Polyroof VIP Insulation and Carrier Layer)

Outline Specification - PR20207 Protec Warm Roof Refurbishment (Rockwool Insulation with Carrier Layer)

Outline Specification - PR20207 Protec Warm Roof Refurbishment (Rockwool Insulation with Carrier Layer)

Outline Specification - PR20209 Protec Warm Roof Refurbishment (Rockwool Tapered Insulation and Carrier Layer)

Outline Specification - PR20209 Protec Warm Roof Refurbishment (Rockwool Tapered Insulation and Carrier Layer)

Outline Specification - PR20303 Protec Warm Roof Refurbishment (Carrier Layer)

Outline Specification - PR20303 Protec Warm Roof Refurbishment (Carrier Layer)

Outline Specification - PR20305 Protec Overlay to Timber Deck

Outline Specification - PR20305 Protec Overlay to Timber Deck

Outline Specification - PR20308 Protec Warm Roof Refurbishment (Carrier Layer) - Mech Fixed

Outline Specification - PR20308 Protec Warm Roof Refurbishment (Carrier Layer) - Mech Fixed

Outline Specification - PR20105 Protec Cut-to-Falls Adhesively Bonded Insulation

Outline Specification - PR20105 Protec Cut-to-Falls Adhesively Bonded Insulation

Outline Specification - PR20304 Protec Warm Roof New Build (Carrier Layer)

Outline Specification - PR20304 Protec Warm Roof New Build (Carrier Layer)

Outline Specification PR20301 Protec Warm Roof New Build Acoustic Adhesively Bonded Insulation

Outline Specification PR20301 Protec Warm Roof New Build Acoustic Adhesively Bonded Insulation

Outline Specification - PR20210 Protec Warm Roof New Build (Rockwool Tapered Insulation and Carrier Layer)

Outline Specification - PR20210 Protec Warm Roof New Build (Rockwool Tapered Insulation and Carrier Layer)

Outline Specification - PR20208 Protec Warm Roof New Build (Rockwool Insulation with Carrier Layer)

Outline Specification - PR20208 Protec Warm Roof New Build (Rockwool Insulation with Carrier Layer)

Outline Specification - PR20206 Protec Warm Roof New Build (Polyroof VIP Insulation and Carrier Layer)

Outline Specification - PR20206 Protec Warm Roof New Build (Polyroof VIP Insulation and Carrier Layer)

Outline Specification - PR20204 Protec Balcony Warm Roof (Cut-to-Falls Insulation) New Build (Adhesively Bonded Insulation)

Outline Specification - PR20204 Protec Balcony Warm Roof (Cut-to-Falls Insulation) New Build (Adhesively Bonded Insulation)

Outline Specification - PR20108 Protec Warm Roof (New Timber Deck and Carrier Layer)

Outline Specification - PR20108 Protec Warm Roof (New Timber Deck and Carrier Layer)

Outline Specification - PR20202 Protec Balcony Warm Roof New Build (Adhesively Bonded Insulation)

Outline Specification - PR20202 Protec Balcony Warm Roof New Build (Adhesively Bonded Insulation)

Outline Specification - PR20107 Protec Warm Roof (New Timber Deck)

Outline Specification - PR20107 Protec Warm Roof (New Timber Deck)

Outline Specification - PR20106 Protec Warm Roof New Build Cut-to-Falls Adhesively Bonded Insulation

Outline Specification - PR20106 Protec Warm Roof New Build Cut-to-Falls Adhesively Bonded Insulation

Outline Specification - PR20102 Protec Warm Roof New Build Mech Fixed Insulation

Outline Specification - PR20102 Protec Warm Roof New Build Mech Fixed Insulation

Case studies

Fleming Park Leisure Centre

Fleming Park Leisure Centre

Barton Hill Academy

Barton Hill Academy

Beckfoot Allerton Primary School

Beckfoot Allerton Primary School

Blackfordby St Margaret’s Primary School

Blackfordby St Margaret’s Primary School

Trinity Buoy Wharf

Trinity Buoy Wharf

Ryhope Hospital

Ryhope Hospital

Dungannon Council Offices

Dungannon Council Offices

Burton Green Primary School

Burton Green Primary School

Aston Martin Headquarters

Aston Martin Headquarters

Woodholm Curved Metal Finish Roof

Woodholm Curved Metal Finish Roof