Verified by manufacturer 3 months ago
Warm Roof Non-Combustible/ Acoustic Insulation (Refurbishment)
BBA Agrément Certificate
Certificate type
European Technical Approval (ETA)
Certificate type
EPD
Certificate type
ISO 9001 Quality Management
Certificate type
UK Technical Assessment (UKTA)
Certificate type
A range of warm roof systems with a cold-applied liquid membrane finish.
Suitable for flat and pitched roofs, balconies, terraces and walkway applications.
Protec is a highly versatile, fast curing, fully reinforced cold liquid applied membrane system, suitable for a wide range of roofing and waterproofing applications.
The Protec RapidCure technology utilizes catalyst, accelerators and inhibitors allowing full control over cure times across a wide range of temperatures all year round. The seamless Protec membrane features the optimum combination of flexibility and toughness, making it suitable for roofs, terraces and walkways of all sizes including situations requiring regular foot traffic. Where new insulation is required, the Protec Warm Roof System can be specified as a flat or tapered scheme to provide a highly efficient solution and meet the very highest thermal performance requirements. Protec offers lasting weatherproof protection for at least 30 years (BBA Cert. No. 09/4676) and is supported by Polyroof’s Approved System Guarantees for up to 25 years.
Features and benefits:
Please consult Polyroof Products Ltd for further specification advice.
Color | Grey Other Guidance for specification option: Bespoke / Specials available, consult manufacturer for details. |
Finish | Smooth Guidance for specification option: Seamless, watertight finish. |
Material | Polymer Guidance for specification option: Flexible hybrid polymer Polyisocyanurate (PIR) Expanded polystyrene (EPS) Stonewool |
Shape | Other |
Length | Bespoke Manufacturer guidancePlease refer to project specific drawings. Formed on site. |
Width | Bespoke Manufacturer guidancePlease refer to project specific drawings. Formed on site. |
Height | Bespoke Manufacturer guidanceVariable - dependent upon thermal performance requirement. |
Warranty description | 20 year Guidance for specification option: As standard. 25 year Guidance for specification option: Subject to specification and discussions with Polyroof Products Ltd. |
Uniclass | |
CAWS | J31/10 Warm deck roof coating J31/120 Warm deck roof coating |
Preparation | |
Horizontal work | Manufacturer guidancePlease consult Polyroof for guidance and insert requirements. |
Skirtings and vertical work | Manufacturer guidancePlease consult Polyroof for guidance and insert requirements. |
Air and vapour control layer | Existing waterproofing (made good).Polyroof SA Vapour Control Layer.Guidance for specification option: With Polyroof SA Primer. |
Insulation | |
Type | Rockwool HARDROCK Multi-Fix DD.Guidance for specification option: Thickness dependent upon U-value requirement. |
Fixing | Adhesively Bonded / Mechanically Fixed. Dependant upon Wind Loading Calculation Data (BS EN 1991 – 1-4:2005 (Eurocode 1)). |
Overlay | |
Type | Not required for this system. |
Carrier membrane | |
Type | Polyroof SA Carrier Layer.Guidance for specification option: With Polyroof SA Primer. |
Liquid-applied waterproofing | |
Type | Cold Liquid Applied Protec Resin with catalyst (two coats). |
Reinforcement | Polymat 450 (first coat). |
Surface treatment | None.Paving (with pedestals).Decking (with pedestals).Polyroof Anti-slip (Mineral Slate) – Maintenance Traffic.Guidance for specification option: Following clients request, third coat of Cold Liquid Applied Protec Resin. Broadcast in Mineral Slate. For further guidance, consult manufacturer. Polyroof Anti-slip (ProGrip) – Maintenance Traffic.Guidance for specification option: Following clients request, one coat of ProGrip Anti-Slip Coating. For further guidance, consult manufacturer. |
System accessories | None.Polyroof pre-formed GRP Trims - drip/ upstand.Polyroof pre-formed GRP Trims - fillet.Polyroof pre-formed GRP Trims - termination barPolyroof pre-formed GRP Trims - simulated metal finish - standing seam.Polyroof pre-formed GRP Trims - simulated metal finish - lead roll.Polyroof pre-formed Internal Outlets.Polyroof pre-formed Through Wall Outlets.Polyroof Insulation Adhesive.Polyroof Fall Arrest Systems.Round Lightning Conductor Clip.Polyroof Fixing Plates (for PV cells / Balustrade systems).Polyroof PR Rooflights.Fixings - EJOT TKR, associated stress plates and plastic tube washers.Fixings - EJOT TKE, associated stress plates and plastic tube washers.Fixings - EJOT FBS, associated stress plates and plastic tube washers.Fixings - EJOT FPS, associated stress plates and plastic tube washers.Structural Repair Mortar. |
Execution | Installation by Polyroof approved contractors. |
Colour | Light Grey. Chromite Grey. Quartz Grey. RAL specials. BS specials. |
Fire performance | Achieves Broof T4 classification in accordance with BBA certificate (09/4676)/ A1 (Rockwool) |
Cure time | 30–60 minutes. |
Application temperature | 3–30°C. Guidance for specification option: The system can be installed down as low as 1°C deck temperature with the addition of Product Accelerators. |
Substrate | Existing build-up. Strip back to underlying deck - Concrete. Strip back to underlying deck - Structural Metal Roof Deck. |
Fall | Flat. Pitched. Flat and pitched. |
Third-party certification | BBA Certificate Number 09/4676. |
Slip resistance | Tested to BS 7976-2: 2002. |
Resistance to water penetration | Suitable for use with zero falls in accordance with BBA certificate (09/4676). |
Country of material origin | United Kingdom |
Country of product manufacture | United Kingdom |
Material | Polymer Guidance for specification option: Flexible hybrid polymer Polyisocyanurate (PIR) Expanded polystyrene (EPS) Stonewool |
NBS BIM Object Standard
This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.
Find out more about the NBS BIM Object Standard.
Platform | Compatible | Version |
---|---|---|
- | 1 | |
- | 1 |
Polyroof Seamless Waterproofing Solutions
Modular Construction Solutions
Green Roof Addition Sheet - Protec
System TDS Protec System
Protec Declaration of Performance
Outline Specification - PR20201 Protec Balcony Warm Roof Refurbishment (Adhesively Bonded Insulation)
Outline Specification - PR20205 Protec Warm Roof Refurbishment (Polyroof VIP Insulation and Carrier Layer)
Outline Specification - PR20207 Protec Warm Roof Refurbishment (Rockwool Insulation with Carrier Layer)
Outline Specification - PR20209 Protec Warm Roof Refurbishment (Rockwool Tapered Insulation and Carrier Layer)
Outline Specification - PR20303 Protec Warm Roof Refurbishment (Carrier Layer)
Outline Specification - PR20305 Protec Overlay to Timber Deck
Outline Specification - PR20308 Protec Warm Roof Refurbishment (Carrier Layer) - Mech Fixed
Outline Specification - PR20105 Protec Cut-to-Falls Adhesively Bonded Insulation
Outline Specification - PR20304 Protec Warm Roof New Build (Carrier Layer)
Outline Specification PR20301 Protec Warm Roof New Build Acoustic Adhesively Bonded Insulation
Outline Specification - PR20210 Protec Warm Roof New Build (Rockwool Tapered Insulation and Carrier Layer)
Outline Specification - PR20208 Protec Warm Roof New Build (Rockwool Insulation with Carrier Layer)
Outline Specification - PR20206 Protec Warm Roof New Build (Polyroof VIP Insulation and Carrier Layer)
Outline Specification - PR20204 Protec Balcony Warm Roof (Cut-to-Falls Insulation) New Build (Adhesively Bonded Insulation)
Outline Specification - PR20108 Protec Warm Roof (New Timber Deck and Carrier Layer)
Outline Specification - PR20202 Protec Balcony Warm Roof New Build (Adhesively Bonded Insulation)
Outline Specification - PR20107 Protec Warm Roof (New Timber Deck)
Outline Specification - PR20106 Protec Warm Roof New Build Cut-to-Falls Adhesively Bonded Insulation
Outline Specification - PR20102 Protec Warm Roof New Build Mech Fixed Insulation