Verified by manufacturer 15 days ago
BBA Agrément Certificate
Certificate type
High performance gas resistant, waterproof membrane for basements and structures.
Provides a vapour and waterproof membrane to water excluding structures and protects concrete from attack by ground salts.
A cold applied flexible methane, radon and carbon dioxide resisting waterproof membrane incorporating an aluminium layer and a polymer modified bitumen compound on a high strength polymer backing film.
Features and benefits:
Supports construction of Passivhaus buildings which can achieve net zero carbon emissions over the life of the structure. Energy required for heating can be 90% less than a conventional design.
Color | Silver |
Material | Bitumen Polymer Aluminium |
Length | Bespoke |
Width | Bespoke |
Height | Bespoke |
Warranty description | Manufacturer guidanceA project specific warranty document for an agreed period for products supplied in accordance with a detailed specification document is available on request. |
Uniclass | |
CAWS | J40/40 Self-adhesive bitumen membranes J40/190 Self-adhesive bitumen damp proofing/ tanking J40/180 Self-adhesive bitumen membranes J40/45 Self-adhesive bitumen gas retardant damp proofing/ tanking |
Classification data | |
Standard | To EN 13707 and EN 13970. |
Third-party certification | British Board of Agrément (BBA) Certificate. |
Form | Gas-resistant, waterproofing membrane. |
Material | |
Carrier material | Polymer. |
Bitumen modification | Polymeric. |
Gas inhibitor | Aluminium foil. |
Thickness (minimum) | To BS EN 1849-1, 1.2 mm. |
Wall to floor junctions | Fix Proofex Angle Fillet Strip. |
Internal and external angles | Proofex Detail Strip. 300 mm wide strip of Proofex 3000. |
Angle | Provide 25 mm chamfer to all external angles prior to application of the reinforcing strip. |
Declaration of conformity | UK 9-35. Manufacturer guidanceDeclaration of performance. |
TensileStrength | To EN 12311-1, Longitudinal >195 N/50 mm; Transverse >200 N/50 mm. |
Elongation at break | To EN 12311-2, Longitudinal >40%, Transverse >40%. |
Resistance to impact | NPD. |
Static load resistance | To BS EN 12730, Met A, 15 kg; Met B, 20 kg. |
Tear resistance | To EN 12310-2, Longitudinal >50 N, Transverse >45 N. |
Impermeability (to BS EN 1928) | ≥60 kPa. |
Radon transmittance | 0.47 E-9 m/s. Manufacturer guidanceRadon transmission rate. |
Methane gas permeability | <5 cc/m² x 24h x atm. |
Radon transmission rate 0.47 x 10-9m/s SP. Radon gas permeability | 0.56 E-12 m²/s. Manufacturer guidancePermeability to radon gas. |
Adhesion to concrete | 4.9 N/mm. Manufacturer guidanceAdhesion to primed concrete. |
SolarReflectance | 103. Manufacturer guidanceSolar reflective index. |
Application temperature | 5–45°C. |
Service temperature | -40 to +80°C. |
Joint | 50 mm side laps, 150 mm end laps. Manufacturer guidanceJoint laps. Recommended. |
Contains Red List materials | No |
Country of material origin | Italy |
Country of product manufacture | Italy |
Material | Bitumen Polymer Aluminium |
Recyclability | non-recyclable |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 0 % |