NBS Source
I'm a manufacturer
Compare variants

Powerdeck® F - Insulation

Verified by manufacturer 1 month ago

110 mm

Recticel Insulation Variant:
Third party certifications:
  • BBA Agrément Certificate

    BBA Agrément Certificate

    Certificate type

  • CCPI Product

    CCPI Product

    Certificate type

Rigid PIR insulation for warm flat roofs under built-up felt, mastic asphalt and single ply membrane waterproofing.

Jump to:
+44 (0)1782 590470 Website

Application

For flat roofs under built-up felt, mastic asphalt and single-ply membrane waterproofing systems. 

Description

Powerdeck® F is a high performance rigid polyisocyanurate (PIR) foam board for use in warm flat roofs under built-up felt, mastic asphalt and approved single ply membrane waterproofing systems. It is faced both sides with a mineral coated glass tissue.


Mastic asphalt waterproofing

An isolating layer of Type 4A sheathing felt must always be used in mastic asphalt waterproofing systems. This isolates the asphalt from movement in the substrate, allows the lateral movement of moisture vapour and warm air during installation of the asphalt and acts as a vapour pressure release in service.


Roof drainage

To ensure adequate drainage the roof should have a minimum finished fall of 1:80. This may mean designing for twice the minimum finished fall to account for building inaccuracies, roof deflection and building settlement. Powerdeck® F boards are also available for tapered insulation schemes.


Thermal bridging

With increasing levels of insulation it is important to ensure the continuity of insulation at the junction of elements.


Wind uplift

The wind uplift force exerted on the roof will vary according to geographical location, site location and building height. Reference should be made to BS 6229 for adequate bonding of the vapour control layer to the deck to help resist wind uplift. Calculations relating to the bonding and any supplementary fixings should be made with reference to BS 6399.


Features and benefits:

  • Manufactured to ISO 9001 Quality and ISO 14001 Environmental Management Systems.
  • Manufactured using a blowing agent with zero ozone depletion potential (ODP) and low global warming potential (GWP).
  • Thermal conductivity as low as 0.024 W/m·K (depending on thickness).
  • Available in tapered format to assist roof drainage.
  • No requirement for roof ventilation and condensation within the roof is avoided as the structure is maintained at the internal temperature.
  • CE marked in accordance with harmonized European standard EN 13165.

General information

Color

White

Material

Polyisocyanurate (PIR)

Guidance for specification option:

Polyisocyanurate (PIR).

Shape

Rectangle

Length

1200 mm

Width

600 mm

Height

50 mm

80 mm

100 mm

120 mm

130 mm

Show more

Manufacturer guidance

90

Uniclass

Pr_25_71_63_66 Polyisocyanurate (PIR) foam boardsPrimary

CAWS

J21/10 Warm deck roof coating

J21/420 Rigid urethane foam insulation

J41/10 Reinforced bitumen membrane warm deck roof covering

J41/420 Rigid urethane foam insulation

J42/10 Warm deck roof covering

J42/420 Rigid urethane foam insulation

Specification data - Polyisocyanurate (PIR) foam boards

Standard

To BS EN 13165.

Third-party certification

BBA certification.

Fire performance

Reaction to fire (product as such) - EN 13501-1 - Euroclass F.

Guidance for specification option:

When tested in accordance with BS 476-3 and CEN/TS 1187, a system comprising 18 mm plywood deck, a polyester reinforced aluminium core VCL, a 120 mm thick insulation board, a layer of 1.7 mm thick IKO Systems S-A underlay and a IKO Ultra prevENt bitumen membrane, achieved an EXT.F.AC and Broof(t4) (Low vulnerability in Scotland) rating respectively and is acceptable for use less than 6 m from a relevant boundary.

Compressive strength at 10% deformation

Exceeds 150 kPa at yield.

Guidance for specification option:

Suitable for loads associated with maintenance traffic. For heavier traffic, extra precautions should be taken (consult the waterproofing manufacturer for appropriate details). Care must be taken to avoid damage to boards by impact or concentrated loads during installation.

Face size (length x width)

1200 x 600 mm.

Manufacturer guidance

(Other sizes available on request).

Density

± 30 kg/m³.

Facing

Faced both sides with a mineral coated glass tissue.

Edges

Straight.

Sustainability data

Material

Polyisocyanurate (PIR)

Guidance for specification option:

Polyisocyanurate (PIR).

Third party certifications

BBA Agrément Certificate

BBA Agrément Certificate

BBA Certificate 24/7232 Powerdeck F

CCPI Product

CCPI Product

CCPI Assessed - Powerdeck® F

Literature

Powerdeck F flat roof insulation technical datasheet

Powerdeck F flat roof insulation technical datasheet

Recticel Insulation Flat Roof Specification Guide V1.5

Recticel Insulation Flat Roof Specification Guide V1.5

Recticel Insulation Product Guide

Recticel Insulation Product Guide

Similar products from Recticel Insulation

Eurothane® Eurodeck - Insulation

Eurothane® Eurodeck - Insulation

Eurothane® GP - Rigid PIR Insulation

Eurothane® GP - Rigid PIR Insulation

Eurothane® PL - Insulation/Plasterboard

Eurothane® PL - Insulation/Plasterboard

Eurowall® + - Insulation

Eurowall® + - Insulation

Eurowall® Cavity - Insulation

Eurowall® Cavity - Insulation

Plylok® - Insulation

Plylok® - Insulation

Powerdeck® U - Insulation

Powerdeck® U - Insulation