Verified by manufacturer 12 hours ago
BBA Agrément Certificate
Certificate type
Rigid PIR insulation for warm flat roofs under mechanically fixed single ply membranes.
For warm flat roofs under mechanically fixed single-ply membrane waterproofing systems.
Eurothane Eurodeck™ insulation is a high performance rigid polyisocyanurate (PIR) foam board for use in warm flat roofs under mechanically fixed single ply membrane waterproofing systems. It is faced on both sides with a multi-layer coated aluminium foil W/m·K.
Roof drainage
To ensure adequate drainage the roof should have a minimum finished fall of 1:80. This may mean designing for twice the minimum finished fall to account for building inaccuracies, roof deflection and building settlement.
Thermal bridging
With increasing levels of insulation it is important to ensure the continuity of insulation at the junction of elements.
Wind uplift
The wind uplift force exerted on the roof will vary according to geographical location, site location and building height. Reference should be made to BS 6399 and the membrane manufacturer’s recommendations for the number of fixings and the fixing pattern.
Features and benefits:
Color | White Silver |
Material | Polyisocyanurate (PIR) Guidance for specification option: Polyisocyanurate (PIR). |
Shape | Rectangle |
Length | 2400 mm |
Width | 1200 mm |
Height | 25 mm 30 mm 40 mm 50 mm 60 mm |
Uniclass | |
CAWS | J42/10 Warm deck roof covering J42/420 Rigid urethane foam insulation |
Standard | To BS EN 13165. |
Third-party certification | BBA certificate. |
Fire performance | To EN 13501-1, Euroclass F.Guidance for specification option: Class 1 (BS 476-7). Manufacturer guidance(When tested in accordance with BS 476-3: 2004, the rating achieved will vary depending on the single ply membrane used). |
Thermal conductivity (maximum) | 0.022 W/mK. |
Compressive strength at 10% deformation | Exceeds 150 kPa at yield.Guidance for specification option: Suitable for loads associated with maintenance traffic. For heavier traffic, extra precautions should be taken (consult the membrane manufacturer for appropriate details). Care must be taken to avoid damage to boards by impact or concentrated loads during installation. |
Cross section | Uniform thickness. |
Thickness (nominal) | 25 mm.30 mm.40 mm.50 mm.60 mm.70 mm.75 mm.80 mm.90 mm.100 mm.110 mm.120 mm.130 mm.140 mm.150 mm. |
Face size (length x width) | 2400 x 1200 mm. |
Density | ± 30 kg/m³. |
Facing | Faced on both sides with a multi-layer coated aluminium foil. |
Edges | Straight. |
Country of product manufacture | United Kingdom |
Material | Polyisocyanurate (PIR) Guidance for specification option: Polyisocyanurate (PIR). |