Verified by manufacturer 2 months ago
Flexible intumescent pad used to reinstate the fire resistance performance of flexible and rigid wall constructions.
The intended use of PFC Corofil Intumescent Putty Pad CIPP is to reinstate the fire resistance performance of flexible and rigid wall constructions where they have been provided with apertures for the penetration of electrical cables into electrical back boxes.
PFC Corofil Intumescent Putty Pad CIPP is a flexible intumescent pad used to reinstate the fire resistance performance of flexible and rigid wall constructions where they have been provided with apertures for the penetration of electrical cables into electrical back boxes.
The PFC Corofil Intumescent Putty Pad CIPP is supplied pre-cut to size with a peel off strip to both faces to prevent it from bonding materials other than for the desired application. The putty pad is installed by removing the peel off strips and wrapping the pad around the back box where it penetrates the face of the wall and covering the back face of the box.
Available in sizes:
170mm x 170mm x 4mm; to suit single socket box
230mm x 170mm x 4mm; to suit double socket box
Features and benefits:
• Tested to EN 1366-3
• Provides fire resistance performance of 120 minutes integrity and insulation
• Can be used in flexible and rigid walls
• Conditioned to Type Z2: Intended for use in internal conditions with humidity lower than 85% RH excluding temperatures below 0°C, without exposure to rain or UV
• Have an assumed working life of 50 years
Color | Red |
Material | Silicone Guidance for specification option: Silicone-based putty containing an exfoliating intumescent material. |
Uniclass | |
CAWS | P12/350 Intumescent putty |
Product range |
Form | Double socket.Guidance for specification option: 230 x 170 x 4 mm. Single socket.Guidance for specification option: 170 x 170 x 4 mm. |
Fire performance | Up to two hours (120 minutes). Guidance for specification option: To EN 1366-3:2009, when installed in single or double socket boxes within flexible and rigid walls. |
Sound insulation rating | RW (C;Ctr) = 67 (-2;-7) dB. Guidance for specification option: Tested to provide a weighted sound reduction index (Rw) of up to 67 dB. |
Country of material origin | United Kingdom |
Material | Silicone Guidance for specification option: Silicone-based putty containing an exfoliating intumescent material. |