Electrically or manually operated, insulated, sliding and folding industrial doors.
Designed for airplane and helicopter hangars, military vehicle garages, workshops, supermarket loading bays, bus garages and power stations.
Electrically or manually operated, sliding and folding industrial doors with high insulation values available in a range of colours. The doors consist of solid, polyurethane filled panels that are top hung and fold clear of an opening.
Features and benefits:
Color | Red Blue Green Grey White |
Finish | Powder-coated Plastisol Galvanized |
Material | Steel Polyurethane |
Shape | Rectangle Square |
Width | 20000 mm |
Height | 6000 mm |
WarrantyDescription | One year 12 months standard, 24 months with agreed service contract in place. |
Uniclass | |
CAWS | L20/530 Sliding folding external doors |
Grade | External.Internal. |
Format | Top hung. |
Track system | Galvanized steel channel.
|
Door leaf | - |
Construction | Galvanized steel dovetail frame with polyurethane foam injected insulation.Panels are constructed from 1.6 mm thick (52 mm thick panels) or 2 mm thick (62 mm thick panels) cold rolled galvanised dovetail channel frames with spot-welded and mitred corners with L bracket stiffeners and 5 mm thick local reinforcement for hardware. The frame is covered on both sides with 0.7 mm thick galvanised steel sheets and pressure injected to all corners with 50 k.g./m³ CFC-free polyurethane foam to form an extremely strong, rigid, flat panel. |
Finish | LG Plastisol.Insert requirements. Polyester powder coated.Insert requirements. External, LG Plastisol / Internal, Polyester powder coated.Insert requirements. Galvanized steel sheets. |
Operation | Manual. |
Hardware | Powered:
Manual:
Insert requirement. |
Accessories | None.Wicket doors.Vision panels. |
U-value | 0.40 W/m²K. |
Vision panels | Not required. Double-glazed, clear acrylic safety glass 770 x 430 mm. Black thermoplastic 'easyfit’ window frame. Double glazed, argon filled, low E toughened glass 400 x 600 mm. Aluminium window frame with one-piece inner liner tray. Double glazed, argon filled, low E toughened glass 400 x 1200 mm. Aluminium window frame with one-piece inner liner tray. Double glazed, argon filled, low E toughened glass 600 x 600 mm. Aluminium window frame with one-piece inner liner tray. |
Wicket door | Not required. Lever handle furniture. Wicket door opens outwards. Hardware comprises a Briton 5520 mortise sashlock, 25 mm low-profile anodized aluminium lever handles, external Europrofile cylinder with internal thumbturn, 1½ pairs of stainless steel butt hinges and a hidden door limiting stay. 85 mm high step with 40 mm wide aluminium threshold strip. Emergency panic bar furniture. Emergency escape furniture. Wicket door opens outwards. Hardware comprises a Briton 379 panic bar, external override cylinder and finger latch, 1½ pairs stainless steel butt-hinges and a hidden overhead door limiting stay. 85 mm high step with 40 mm wide aluminium threshold strip. |
TypeNot applicable on manual doors. | Not required/ manual. Deadman. Semi-automatic. Automatic. |
Actuation/ SafetyNot applicable on manual doors. | Not required/ manual. Light curtain. Photocells. A FAAC XP15W send/ receive photocell is fitted across the opening. The receiver unit is fitted with a long-life battery to avoid hard wiring. Photocells can be fitted for closing safety, opening safety, or a combination of opening and closing. If a closing safety beam is broken during the closing cycle, the door will automatically stop and re-open. If an opening safety beam is broken during the opening cycle, the door will automatically stop. Photocell/ Traffic light posts. A pair of 100 x 100 RHS right angle steel posts are fitted on the inside of the bunched door leaves to mount an internal photocell and/ or traffic lights. Posts are painted yellow for maximum visibility. Protective barrier around stack area. |
Additional access controlsNot applicable on manual doors. | Not required/ manual. Digi-key. Bewator K42 stainless steel code-lock for operation of the door by authorised persons only. For internal or external use. Push button. Additional Run/Captive stop push button unit. Key switch. Sprung return key-switch in separate enclosure for operation of the door by keyholders only. For internal or external use. Microwave sensor. High level sensor to open the door on detection of oncoming vehicles. Adjustable so as to ignore pedestrians, or parallel traffic. Please note: maximum opening height is 5m for microwave sensors. |
Door leaf configuration | 4+0. |
DimensionsUp to 4000 x 6000 mm (w x h). Insert requirements. | - |
Clearance | 200 mm at the head. |
Power supply | N/A. |
Drive operation | Manual (Manual Doors). Chain driven with low level manual release haul chains. |
Contains Red List materials | No |
Country of material origin | United Kingdom |
Country of product manufacture | United Kingdom |
Recyclability | Materials can be recycled |
Recycled content | 75 % |
NBS BIM object standard
This BIM object has been authored to meet the requirements of the NBS BIM object standard.
Find out more about the NBS BIM object standard.
Platform | Compatible | Version |
---|---|---|
![]() | Revit 2017 | 1 |
![]() | - | 1 |
Osprey Door Specification Sheet
Drawing showing manual hinged Osprey
Drawing showing manual bi-parting hinged Osprey
Drawing showing manual Osprey Folding one way within opening.
Drawing showing Powered Osprey 1 Way
Drawing showing Manual Osprey 1 Way Clear
Drawing show manual Osprey folding 2 ways within opening.
Drawing of manual Osprey folding two ways clear of opening
Drawing for Powered Bi-Parting Osprey
Phoenix Brochure