NyRock® Rainscreen 032 - Insulation

Verified by manufacturer 3 months ago

50 mm.

ROCKWOOL Ltd Variant:
Third party certifications:
  • BBA Agrément Certificate

    BBA Agrément Certificate

    Certificate type

Low lambda non-combustible stone wool insulation for ventilated facades.

Jump to:
BOS
+44 (0)1656 862621 Website

Application

  • Steel frame, timber frame or masonry walls in conjunction with a cladding system.
  • Steel frame or timber frame with a masonry outer leaf.

Description

NyRock® Rainscreen 032 is a stone wool insulation product specifically developed for use within ventilated cladding systems, as well as sealed systems such as curtain walling.


Manufactured using patented technology, NyRock Rainscreen 032 has a more efficient fibre structure that increases the density of air pockets trapped within each slab. This results in an improved thermal performance when compared to traditional stone wool products.


Once installed, the product’s high density works in combination with a factory applied water repelling agent to give improved resistance to rain ingress during construction.


The product can be fitted around brackets and other awkward details, and when tightly butted, adjacent slabs effectively ‘knit’ together to provide a continuous insulating layer, reducing heat losses that would otherwise be caused by gaps.


For optimum thermal performance in framed structures, combine NyRock Rainscreen Slab 032 with NyRock Frame Slab 032.


Features and benefits:

  • Low thermal conductivity of 0.032 W/m·K.
  • BBA pending.
  • Non-combustible Euroclass A1.
  • Independently tested acoustic benefits.
  • Water repellent yet breathable.
  • Can be recycled and reprocessed, reducing landfill costs, with zero ozone depletion potential (ODP) and global warming potential (GWP).
  • Stone wool is dimensionally stable and has been proven to provide the same performance for more than 55 years after installation.
  • Compatible with masonry restraint systems.


For use on steel frame, timber frame, or masonry walls in

conjunction rainscreen cladding:

  • Slabs should be close-butted at all vertical and horizontal joints. The horizontal joints of the insulation should be staggered in accordance with good practice.
  • Fixings should have a minimum head diameter of 70 mm. A typical fixing pattern has three fixings per square metre with one metal fixing at the centre of every slab.
  • The product should be cut and tightly fitted around cladding support elements.
  • For a typical installation, a breathable membrane is placed between the sheathing board and the product A vapour control layer (VCL) is placed between the plasterboard and the frame.


For use on steel frame or timber frame with a brick outer leaf:

  • The slabs should be close-butted at all vertical and horizontal joints, and at corners. The horizontal joints of the slabs should be staggered, in accordance with good practice.
  • Slabs should be carefully cut to fit around any protrusions into the cavity.
  • A VCL is placed between the plasterboard and the frame. A breathable membrane is placed between the sheathing board and the product.
  • The insulation should be installed to coincide with the frame, with retaining discs used in conjunction with the wall ties at no more than 600 mm horizontally and 450 mm vertically.
  • After each section of the leading leaf is built, excess mortar should be removed from the cavity face and mortar droppings cleaned from exposed edges of the installed board, before installation of the next run of boards.

General information

Color

Yellow

Material

Stonewool

Shape

Rectangle

Length

1200 mm

Width

600 mm

Height

50 mm

55 mm

60 mm

65 mm

70 mm

Show more

Uniclass

Pr_25_57_06_56 Mineral wool slab insulationPrimary

CAWS

H92/776 Thermal insulation

P10/217 Insulation slabs fixed to backing wall

H11/110 Curtain walling

H11/780 Thermal insulation

P10/42 Mineral wool insulation slabs fixed to backing wall

Specification data - Mineral wool slab insulation

Standard

To EN 13501-1, BS EN 13162.

Thickness

50 mm.

Manufacturer guidance

Consult manufacturer's literature for example U-values based on various cladding systems, with or without NyRock Frame Slab 032.

Edges

Square.

Density

Manufacturer's standard.

Thermal conductivity (maximum)

0.032 W/m·K.

Compressive strength (minimum)

Manufacturer's standard.

Fire performance

To BS EN 13501-1, A1.

Sound insulation rating

Manufacturer's standard.

Guidance for specification option:

Consult manufacturer's literature for details.

Vapour resistivity

5.9 MNs/gm.

Cavity barriers

-

Manufacturer guidance

Insert requirements.

Manufacturer recommends the use of SP Firestop vertically and SP Firestop or SP Firestop OSCB horizontally, depending on outer leaf. Consult manufacturer's literature for details.

Fixing

-

Manufacturer guidance

To be secured to the substrate with metal and polypropylene fixings; consult manufacturer's literature for details and insert requirements.

Horizontal joints should be staggered and all joints tight

butted.

Sustainability data

Country of material origin

United Kingdom

Country of product manufacture

United Kingdom

Recyclability

Can be recycled

BIM objects

BOS

NBS BIM Object Standard

This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.

Find out more about the NBS BIM Object Standard.

Platform Compatible Version
IFC
-

1

Revit
-

1

Third party certifications

BBA Agrément Certificate

BBA Agrément Certificate

NyRock Rainscreen 032 -BBA Cert No: 22/6417