VariCheck FR is a class B flame resistant, variable vapour check barrier, for use as an internal air and vapour control layer (AVCL).

Jump to:
01795 515 110 Website

Application

Suitable for use in insulated wall or roof applications and floor applications where a fire rating is not required.


Air and Vapour Control Layers (AVCL) should be installed on the warm side of the building envelope, within all insulated wall or roof applications and it is recommended to use Novia 30 mm double sided butyl tape and Novia 96 mm wide BS 476 cold weather aluminium foil lap tape.

Description

Novia® VariCheck FR is a class B flame resistant, variable vapour check barrier for use as an internal air and vapour control layer (AVCL).


Suitable for use in insulated wall or roof applications where low moisture vapour resistance is required.


The permeability of the membrane varies seasonally with changes to local humidity levels, as the membrane is less permeable in colder months, and more permeable in warmer months.


Features and benefits:

  • CE approved to BS EN 13984.
  • Fire classification to EN 13501-1, B-s1,do.
  • Low cost, fire rated option for both standard and high rise constructions.
  • Variable water vapour permeability, sd 0.4–3.2 m.
  • Fully airtight air leakage barrier.
  • Translucent material, for easy on-site installation to battens.
  • Helps towards BS 5250 requirements.

General information

Color

White

Finish

Textured

Material

Polymer

Guidance for specification option:

Reinforced, foil faced.

Shape

Other

Length

50000 mm

Manufacturer guidance

Overall roll length.

Width

1500 mm

Manufacturer guidance

Overall roll width.

Warranty description

Lifetime

Uniclass

Pr_25_57_65_60 Plastics sheetsPrimary

CAWS

H30/261 Air and vapour control membrane

K11/145 Battened cement-bonded particleboard floating floor

H31/261 Air and vapour control membrane

P10/60 Air and vapour control layer

H31/45 Air and vapour control membrane

H30/30 Air and vapour control membrane

J42/395 Air and vapour control layer

H92/780 Air and vapour control layer

J41/395 Air and vapour control layer

J31/330 Air and vapour control layer

K21/146 Laminate flooring

K21/145 Composite laminate flooring

K21/140 Battened wood laminate flooring

K21/130 Battened wood floating floor

K21/120 Battened wood flooring

K21/115 Wood laminate flooring

K21/111 Wood floating floor

K21/110 Wood flooring

K11/795 Wall lining on metal framing

K11/245 Cement bonded particleboard floating floor

K11/235 Oriented strand board floating floor

K11/225 Particleboard floating floor

K11/215 Plywood floating floor

K11/135 Battened oriented strand board floating floor

K11/125 Battened particleboard floating floor

K11/115 Battened plywood floating floor

K10/155 Wall lining system (metal studs)

P10/310 Air and vapour control layer

H20/150 Sheet cladding (attached to metal support systems)

J21/395 Air and vapour control layer

Specification data - Plastics sheets

Material

Polymer.

Purpose

Fire rated variable air and vapour control layer.

Guidance for specification option:

Fixed with Novia 30 mm wide double sided butyl tape and 96 mm wide BS 476 cold weather foil lap tape for all airtight applications.

Standard

To BS EN 13948.

Performance characteristics

-

Tensile strength (minimum)

To BS EN 12311-1, MD/CD: >120/>100 N/50 mm.

Tear resistance

To EN 13859-1, MD/CD: >65/>65 N.

Elongation to break

To EN 13859-1, MD/CD: >50/>50%.

Water vapour resistance (minimum)

To EN 1931, 2.5 m.

Guidance for specification option:

0.4–3.2 m, humidity variable.

Manufacturer guidance

Water vapour permeability in Sd.


Fire performance

To EN 13501-1, Class B-s1, d0.

Guidance for specification option:

Valid for substrates with fire class A2-s1, d0 or A1 such as 12 mm plasterboard, with no cavity between product and substrate.

Recycled content

None.

Physical properties

-

Colour

White.

Weight (minimum)

90 g/m².

Manufacturer guidance

To EN 1849-2.

Dimensions

-

Width (minimum)

1.5 m.

Guidance for specification option:

Roll width.

Roll length (minimum)

50 m.

Roll weight

7 kg.

Resistance to water penetration

To EN 1928, pass.

Tape

Not required.

Novia Double sided butyl tape.

Novia Cold weather aluminium foil lap tape.

Sustainability data

Contains Red List materials

No

Country of material origin

Europe

Country of product manufacture

Europe

Material

Polymer

Guidance for specification option:

Reinforced, foil faced.

Literature

Novia VariCheck FR Class B-s1,d0 Fire rated Variable Vapour Check Air & Vapour Control Layer.