Verified by manufacturer 2 months ago
Class B‐s1,d0 fire rated breather membrane for use on external façade & insulated wall applications over 18m in height. Novia FR is dual CE approved and can be also used in pitched roof applications.
For use behind insulated external façade installations. Approved for use in high rise wall applications as part of an SFS type light steel frame, and insulated external wall build up. Can also be used on pitched roofs.
Novia FR is a Class B‐s1,d0 fire rated breather membrane primarily used as a fire rated membrane for behind external façades attached to such as SFS light steel frame wall lining systems providing a waterproof yet breathable fire rated covering.
Novia FR is dual CE approved meaning it can be used for both pitched roofs as well as external wall applications. Novia FR is water penetration resistant to W1 which is the highest standard of water penetration resistance, excellent breathability, air tight (when taped and sealed correctly), it is also lightweight and easy to handle.
Novia FR is black on the front and white on the reverse side, with an overlap line for ease of installation. There are no text or images on either side. Novia FR meets EN 13859‐1 for pitched roofing and EN 13859‐2 for walls.
Features and benefits:
Color | Black Manufacturer guidanceBlack on front and white on the reverse side. |
Finish | Film Manufacturer guidanceNo logo printed. |
Material | Polyurethane Guidance for specification option: Thermoplastic polyurethane (TPU)/ non‐woven laminate. |
Shape | Other |
Length | 50000 mm |
Width | 1500 mm |
Warranty description | Lifetime |
Uniclass | |
CAWS | H20/150 Sheet cladding (attached to metal support systems) H20/155 Sheet cladding (attached to timber battens) H21/110 Vertical timber weatherboarding H21/111 Horizontal timber weatherboarding H21/115 Vertical timber weatherboarding H21/116 Horizontal timber weatherboarding H21/130 Breather membrane H21/20 Breather membrane H30/110 Fibre cement H30/120 Fibre cement H30/350 Breather membrane H30/50 Breather membrane H31/280 Breather membrane H31/55 Breather membrane H60/105 Clay roof tiling H60/110 Clay roof tiling with counterbattens H60/120 Concrete roof tiling H60/125 Concrete roof tiling with counterbattens H60/145 Clay vertical tiling H60/155 Concrete vertical tiling H61/105 Roof slating H61/110 Roof slating with counterbattens H61/120 Vertical slating H62/105 Roof slating H62/110 Roof slating with counterbattens H62/120 Vertical slating H62/125 Roof slating H62/130 Roof slating with counterbattens H62/140 Vertical slating H62/145 Roof slating H62/150 Roof slating with counterbattens H64/110 Wood shingle/ shake roofing H64/120 Wood shingle/ shake roofing with counterbattens H64/130 Vertical wood shingle/ shakes H65/105 Clay roof tiling H65/110 Clay roof tiling with counterbattens H65/115 Concrete roof tiling H65/120 Concrete roof tiling with counterbattens H65/125 Reconstituted slate roof tiling H65/130 Reconstituted slate roof tiling with counterbattens H65/135 Ceramic slate roof tiling H65/140 Ceramic slate roof tiling with counterbattens H67/110 Metal roof tiling H67/120 Metal roof tiling with counterbattens H67/130 Metal vertical tiling H92/120 Rainscreen cladding H92/785 Breather membrane K21/111 Wood floating floor M30/265 Building paper P10/320 Breather membrane P10/65 Breather membrane |
Product range |
Standard | To BS EN 13859-1.To BS EN 13859-2.To EN 13501-1. |
Performance characteristics | Class B fire rated to current Building Regulation requirements. |
Class (minimum) | W1. |
Material | Thermoplastic polyurethane (TPU). |
Form | Non-woven laminate. |
Weight (minimum) | 110 g/m². |
Reflective face | 0%. |
TensileStrength | Machine direction: 270 N/50 mm; cross direction: 175 N/50 mm to EN 12311‐1. |
Elongation (to EN 12311‐1) | 25% to EN 12311‐1. |
Tear resistance | Machine direction: 90 N; cross direction: 100 N to EN 12310‐1. |
Resistance to air penetration | 0.05 m³/(m².h.50 Pa) to EN 12114. |
Sd value | 0.075 m to EN ISO 12572 C. |
Resistance to water penetration | Class W1 to EN 1928A. Class W1 (after ageing) to EN 13859‐1 Annex C. |
Reaction to fire | B‐s1,d0 to EN 13501‐1 (when fitted to A1/ A2 materials, D‐s2,d0 when on wood). |
Low temperature stability | ‐40°C to EN 1109. |
UV resistance | Excellent. |
Contains Red List materials | No |
Country of material origin | Europe |
Country of product manufacture | Europe |
Recyclability | Not recyclable |
Aluthermo RoofReflex® - Insulated Breather Underlay Membrane
Novia Black + Pro Breather Membrane - Roof and wall breather membrane
Novia Black + Supreme Breather Membrane - Roof and Wall Breather Membrane
Novia Black+ Construction Wrap - Breather membrane
Novia Black+ Ultra Roof & Wall Breather Membrane
Novia Building Wrap Wall Breather - Breather Membrane
Novia MirrorWrap W1 Breather Membrane
Novia Reflex Reflective Breather Membrane
Novia UV Facade FR B-s1,d0 fire rated Breather Membrane