NBS Source
I'm a manufacturer

Novia® FlamePro A1 FR Fire Rated Air & Vapour Control Layer - Fire-Rated Vapour Control Layer

Verified by manufacturer 9 days ago

Novia Ltd

A1 fire-rated reflective air and vapour control layer.

Jump to:
01795 515 110 Website

Application

Suitable for use in standard and high-rise applications.

Air and vapour control layers (AVCLs) should be installed on the warm side of the building envelope, within all insulated wall or roof applications and it is recommended to use Novia 30 mm Double Sided Butyl tape and Novia 96 mm wide BS 476 Cold Weather Aluminium Foil Lap tape.

Description

Novia® FlamePro A1 FR is a high-performance, reflective air and vapour control layer (AVCL). Novia® FlamePro A1 FR complies with EN 13501-1 fire classification A1 and is approved for use in high-rise applications. Novia® FlamePro A1 FR has excellent moisture vapour resistance and is suitable for use in any insulated wall or roof application where high moisture vapour resistance is required. Novia® FlamePro A1 FR will provide a very low moisture vapour permeability solution but is also airtight, which improves the thermal performance of the building. The product is reflective on one side and white on the reverse, with no text or images.

Features and benefits:

  • A1 fire classification to EN 13501-1
  • Low moisture vapour permeability, which minimises interstitial condensation.
  • Airtight, which improves thermal performance, reducing energy costs.
  • Helps towards BS 5250 requirements.

General information

Color

Silver

Guidance for specification option:

Reflective.

Finish

Foil

Reflective

Material

Foil

Guidance for specification option:

Reinforced, foil faced.

Glass Fibre

Shape

Other

Guidance for specification option:

Supplied in an easy to handle roll.

Length

50000 mm

Manufacturer guidance

Overall roll length.

Width

1480 mm

Manufacturer guidance

Overall roll width.

Warranty description

Lifetime

Uniclass

Pr_25_57_65_60 Plastics sheetsPrimary

CAWS

P10/60 Air and vapour control layer

P10/310 Air and vapour control layer

Specification data - Plastics sheets

Material

Glass fibre and aluminium foil.

Purpose

Air and vapour control layer.

Guidance for specification option:

Fixed with Novia® 30 mm wide double-sided butyl tape and Novia® 96 mm wide BS 476 cold weather aluminium foil lap tape for all airtight applications.

Performance characteristics

-

Tensile strength (minimum)

>2200 N/50 mm MD and >1600 N/50 mm CD.

Tear resistance

>215 N/50 mm MD and >200 N/50 mm CD.

Elongation to break

>3% MD/ >2% CD.

Water vapour resistance (minimum)

10 000 MN·s/g.

Fire performance

Reaction to fire: to EN 13501-1, Class A1.

Form

Flexible roll.

Physical properties

-

Colour

Silver.

Guidance for specification option:

The product is reflective on one side, white on the reverse, with no text or images.

Weight (minimum)

270 g/m².

Dimensions

-

Width (minimum)

1480 mm.

Roll length (minimum)

50 m.

Sd value

>2000 m.

Sustainability data

Contains Red List materials

No

Country of material origin

United Kingdom

Country of product manufacture

United Kingdom

Material

Foil

Guidance for specification option:

Reinforced, foil faced.

Glass Fibre

Expected Life

Lifetime

Literature

Novia FlamePro A1 Air and Vapour Control Layer Product Datasheet

Novia FlamePro A1 Air and Vapour Control Layer Product Datasheet

Novia FlamePro A1 FR Fire Rated Air & Vapour Control Layer technical information

Novia FlamePro A1 FR Fire Rated Air & Vapour Control Layer technical information

Similar products from Novia Ltd

Novia 1000 Gauge VirginPoly Vapour Control Layer Polythene - Vapour control & air tightness layer

Novia 1000 Gauge VirginPoly Vapour Control Layer Polythene - Vapour control & air tightness layer

Novia 1200 Gauge Vapour Control Layer - Vapour control & air tightness layer

Novia 1200 Gauge Vapour Control Layer - Vapour control & air tightness layer

Novia 1600G Radon Barrier - Gas Barrier and DPM

Novia 1600G Radon Barrier - Gas Barrier and DPM

Novia 500 Gauge VirginPoly Vapour Control Layer Polythene  - Vapour control & air tightness layer

Novia 500 Gauge VirginPoly Vapour Control Layer Polythene - Vapour control & air tightness layer

Novia STRP ProMax Air & Vapour Control Layer

Novia STRP ProMax Air & Vapour Control Layer

Novia STRP Vapour Control Layer

Novia STRP Vapour Control Layer

Novia VariCheck FR Class B-s1,d0 Fire Rated Variable Air and Vapour Control Layer

Novia VariCheck FR Class B-s1,d0 Fire Rated Variable Air and Vapour Control Layer

Novia VC2 Air Leakage and Vapour Control Layer

Novia VC2 Air Leakage and Vapour Control Layer

Novia VC200 Reflective Air and Vapour Control Layer

Novia VC200 Reflective Air and Vapour Control Layer

Novia VC4000 FR Class B-s1, d0 Fire Rated Reflective Vapour Control Layer - Fire rated vapour control layer