Verified by manufacturer 16 hours ago
With deflection head arrangement
CCPI System
Certificate type
EPD
Certificate type
EPD
Certificate type
EPD
Certificate type
EPD
Certificate type
Fire resistance to BS EN 1364-1
Certificate type
The Knauf Performer system is Knauf's most versatile and commonly used partition system.
Plasterboard partition system.
The Knauf Performer system is Knauf's most versatile and commonly used partition system. It is constructed using a single row of Knauf metal studs with Knauf plasterboards to both sides in order to meet fire, acoustic, moisture and impact requirements.
The Performer system is lightweight, simple to construct and should be used in conjunction with Knauf’s finishing solutions range.
Testing Methodology: BS EN 1363-1 AND BS 476-20
Knauf interior drywall partition systems* that achieve a fire resistance performance are tested in accordance with BS EN 1363-1 and BS EN 1364-1. These are the up to date and most rigorous test methodology standards to follow.
Determining the maximum height of a drywall partition as per the BS EN 1363-1 fire test methodology, is typically restricted by the 3 metre height of the test furnace.
To understand the true maximum height of the system whilst under fire test conditions (‘Fire State Height’), there are three options. Increases can be determined by utilising greater test furnace heights, via Extended Field of Application (as outlined in BS EN 15254-3 - it is important to note this standard applies to single metal frame symmetrical systems only), or via BS EN 1364-1.
The BS 476-20 standard is also restricted by the 3 metre height of the test furnace. However, under this BS standard, increasing the maximum heights of a system can be based on the ‘Cold State Height’. The cold state height is calculated using structural engineering methods to L/240 @ 200Pascals. (L = Height of wall). Regulatory Requirements
Specific to Approved Document B (England) there is a requirement to use European classifications and fire resistance test methodologies in accordance with BS EN 1363-1 and BS EN 1364-1, which means that the fire state height must be considered. However, Approved Document B (England) currently allows the usage of the BS 476 series, though it should be noted that, following consultation, the full BS 476 series will be removed in 2029. For other nationals, please consult relevant approved documents, technical guidance, and handbooks.
Knauf Approach & Recommendations:
Knauf advise and promote that EN compliance should be followed. That is to say Knauf advise utilising an BS EN 1364-1 fire resistance test and extend the maximum height of a drywall partition system via either BS EN 15254-3, BS EN 1364-1 or via a fire resistance test within a test rig greater than 3m in height.
Projects that wish to use the BS 476 series must gain agreement between the Client, Accountable Persons, Duty Holders, and Local Building Control that the cold state height is an acceptable methodology. For further information on Knauf system types that are applicable to support projects focusing on BS compliance, refer to Knauf Systems Performance Tables (BS compliance).
Material | Gypsum Metal Glass mineral wool |
Shape | Rectangle Other Square |
Width | Bespoke |
Height | Bespoke |
Warranty description | Lifetime Guidance for specification option: Knauf Specification Disclaimer - Supply of Knauf products and systems for your project is typically made via distribution in accordance with Knauf’s ‘standard terms and conditions of sale. Please be advised that Knauf’s design liability is strictly limited to the manufacture of its tested products and systems, in their tested arrangements, in accordance with the enclosed specification document, specification clauses and standard details. Knauf does not warrant nor accept any liability for the design, overall health and safety or functionality of any interfaces within the building between its stand-alone products and/or systems and any other sections or interfaces. Download the full Specification Disclaimer here: Knauf Specification Disclaimer | Knauf UK | NBS Source View Knauf's Standard Terms and Conditions of Sale here: Manufacturer guidanceThe 100% Knauf System Performance Warranty - Knauf warrants that its Systems will perform to the specified requirements throughout the lifetime of the building, when installed properly and under normal conditions. The 100% Knauf System Performance Warranty guarantees that your Knauf systems are:
Download the full System Performance Warranty here: The 100% Knauf System Performance Warranty | Knauf UK | NBS Source |
Uniclass | |
CAWS | K10/30 Metal stud K10/125 Metal stud partition system |
System performance | |
Sound insulation, Rw (minimum) to BS EN ISO 10140-2 or BS EN ISO 140-3 | 44 Rw (dB). Manufacturer guidanceWhen tested to BS EN 10140-2. |
Fire resistance to BS EN 1364-1 | EI 30. Manufacturer guidanceTested in accordance with BS EN 1364-1. |
Duty rating to BS 5234-2 | Medium duty (MD). Manufacturer guidanceIn accordance with BS 5234-2, clause 1.6.2 & 1.6.3 of Annex B & C. |
Maximum height - cold state | 3400 mm. |
Thickness | 77 mm. Manufacturer guidanceExcluding finishes. |
Classification data | |
Framing | Knauf 50 'C' (0.55) at 300 mm centres to suit maximum height. Head channel: Knauf 52 Deep Flange 'U' Channel (0.70) (70 mm deep flange). Floor channel: Knauf 52 'U' Channel (0.55). |
Insulation | 25 mm Knauf Insulation Acoustic Roll. |
Linings | 1 x 12.5 mm Knauf Soundshield Plus to each side. |
Fasteners | 25 mm Knauf Performance Plus screws. |
Joint treatment | Horizontal joint: Knauf Flat Fixing Plate. |
Finish | For paint finishes: System must be taped and jointed using Knauf Joint Filler (Premium) or Knauf Joint Cement Premium and Knauf Joint Tape (Paper). Or alternative Knauf jointing compounds manufactured to EN 13963. Knauf Wallboard Primer applied once taping and jointing completed. Prior to where paint decoration is required. For preparation for decoration of where gypsum plaster skim is required, the outer layer of plasterboard joints is required to be taped and filled, using Knauf Joint Filler (Premium) and Knauf Joint Tape (Paper) meeting quality level 1 in accordance with Eurogypsum - Drywall Jointing & Finishing - Surface quality level classification. For application where gypsum skim finish is required, the Knauf system is to be taped and filled using Knauf jointing compounds. When using Knauf Performance Plus, the applicator of gypsum skim finish is required to check if pre-treatment is required. |
Execution | Consult manufacturer's literature at https://www.knauf.co.uk/our-services/resources |
Deflection head | For deflection head allowance of up to -25 mm or ±12.5 mm, use 2 x 19 mm Knauf Coreboard fillets. |
System code | EN-PC-50-055-3-1-12.5-SSP-25. Guidance for specification option: The maximum height stated under Partition height (see below) is the cold state height, calculated structurally to limiting deflection of L/240 @ 200 Pa. BS-PC-50-055-3-1-12.5-SSP-25. Guidance for specification option: The maximum height stated under Partition height (see below) is the cold state height, calculated structurally to limiting deflection of L/240 @ 200 Pa. |
Partition height | Manufacturer guidanceInsert requirements, maximum 3400 mm. See System code for further details. |
Country of material origin | Spain Manufacturer guidanceApplies to our natural gypsum only which is the main component of plasterboard. Other components are from other countries. Please contact Knauf for more details. |
Country of product manufacture | United Kingdom Manufacturer guidanceUK applies to the majority of manufacture but a small percentage of finished items may be imported. Please contact Knauf for more details. |
Material | Gypsum Metal Glass mineral wool |
Recyclability | Individual product EPDs for plasterboard and metal components available at: https://www.knauf.co.uk/our-services/resources/environmental-product-declarations-2 |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 12.64 % Manufacturer guidance(2024 average by mass for all UK produced plasterboards, recycled gypsum & paper) |
Knauf Core Board Data Sheet
Knauf C Stud Data Sheet
Knauf DF U Channel Data Sheet
Knauf Fill and Finish Data Sheet
Knauf Fire Rated Deflection Heads Document
Knauf Flat Fixing Plate Data Sheet
Knauf Insulation Acoustic Roll Data Sheet
Knauf Joint Filler Premium Data Sheet
Knauf Paper Joint Tape Data Sheet
Knauf Performance Plus Screws Data Sheet
Knauf Specification Disclaimer
Knauf Soundshield Plus Data Sheet
Knauf Standard Details - Performer Single Boarded
Knauf Systems Performance Tables (BS Compliance)
Knauf Systems Performance Tables (EN Compliance)
Knauf U Channel Data Sheet
The 100% Knauf System Performance Warranty
Supporting guidance on Knauf testing documentation
Knauf 'I' Stud Lining (fire resistance system): ISL-I-70-070-6-2x15-FP-50
Knauf 'I' Stud Lining (fire resistance system): ISL-I-92-090-6-2x15-FP-50
Knauf 'I' Stud Lining (non-fire resistance system): ISL-I-50-055-3-2x15-SSP-50
Knauf 'I' Stud Lining (non-fire resistance system): ISL-I-50-055-4-1-12.5-WB-0
Knauf 'I' Stud Lining (non-fire resistance system): ISL-I-50-055-6-1-12.5-MP-0
Knauf 'I' Stud Lining (non-fire resistance system): ISL-I-50-055-6-1x12.5-WB-0
Knauf 'I' Stud Lining (non-fire resistance system): ISL-I-50-055-6-1x15-SSP-0
Knauf 'I' Stud Lining (non-fire resistance system): ISL-I-50-055-6-2-12.5-WB-25
Knauf 'I' Stud Lining (non-fire resistance system): ISL-I-50-055-6-2-15-SSP-25
Knauf 'I' Stud Lining (non-fire resistance system): ISL-I-50-055-6-2-15-SSP-50