NBS Source
I'm a manufacturer

Compare variants

Knauf Performer: PC-50-055-3-1-12.5-SSP-25
Knauf Performer: PC-50-055-3-1-12.5-SSP-25

Verified 17 hours ago

Knauf UK

With deflection head arrangement

Verified 17 hours ago

Knauf UK

Without deflection head arrangement

Summary
The Knauf Performer system is Knauf's most versatile and commonly used partition system.
The Knauf Performer system is Knauf's most versatile and commonly used partition system.
Application

Plasterboard partition system.

Plasterboard partition system.

Description

The Knauf Performer system is Knauf's most versatile and commonly used partition system. It is constructed using a single row of Knauf metal studs with Knauf plasterboards to both sides in order to meet fire, acoustic, moisture and impact requirements.

The Performer system is lightweight, simple to construct and should be used in conjunction with Knauf’s finishing solutions range.

Testing Methodology: BS EN 1363-1 AND BS 476-20

Knauf interior drywall partition systems* that achieve a fire resistance performance are tested in accordance with BS EN 1363-1 and BS EN 1364-1. These are the up to date and most rigorous test methodology standards to follow.

Determining the maximum height of a drywall partition as per the BS EN 1363-1 fire test methodology, is typically restricted by the 3 metre height of the test furnace.

To understand the true maximum height of the system whilst under fire test conditions (‘Fire State Height’), there are three options. Increases can be determined by utilising greater test furnace heights, via Extended Field of Application (as outlined in BS EN 15254-3 - it is important to note this standard applies to single metal frame symmetrical systems only), or via BS EN 1364-1.

The BS 476-20 standard is also restricted by the 3 metre height of the test furnace. However, under this BS standard, increasing the maximum heights of a system can be based on the ‘Cold State Height’. The cold state height is calculated using structural engineering methods to L/240 @ 200Pascals. (L = Height of wall). Regulatory Requirements

Specific to Approved Document B (England) there is a requirement to use European classifications and fire resistance test methodologies in accordance with BS EN 1363-1 and BS EN 1364-1, which means that the fire state height must be considered. However, Approved Document B (England) currently allows the usage of the BS 476 series, though it should be noted that, following consultation, the full BS 476 series will be removed in 2029. For other nationals, please consult relevant approved documents, technical guidance, and handbooks.

Knauf Approach & Recommendations:

Knauf advise and promote that EN compliance should be followed. That is to say Knauf advise utilising an BS EN 1364-1 fire resistance test and extend the maximum height of a drywall partition system via either BS EN 15254-3, BS EN 1364-1 or via a fire resistance test within a test rig greater than 3m in height.

Projects that wish to use the BS 476 series must gain agreement between the Client, Accountable Persons, Duty Holders, and Local Building Control that the cold state height is an acceptable methodology. For further information on Knauf system types that are applicable to support projects focusing on BS compliance, refer to Knauf Systems Performance Tables (BS compliance).

The Knauf Performer system is Knauf's most versatile and commonly used partition system. It is constructed using a single row of Knauf metal studs with Knauf plasterboards to both sides in order to meet fire, acoustic, moisture and impact requirements.

The Performer system is lightweight, simple to construct and should be used in conjunction with Knauf’s finishing solutions range.

Testing Methodology: BS EN 1363-1 AND BS 476-20

Knauf interior drywall partition systems* that achieve a fire resistance performance are tested in accordance with BS EN 1363-1 and BS EN 1364-1. These are the up to date and most rigorous test methodology standards to follow.

Determining the maximum height of a drywall partition as per the BS EN 1363-1 fire test methodology, is typically restricted by the 3 metre height of the test furnace.

To understand the true maximum height of the system whilst under fire test conditions (‘Fire State Height’), there are three options. Increases can be determined by utilising greater test furnace heights, via Extended Field of Application (as outlined in BS EN 15254-3 - it is important to note this standard applies to single metal frame symmetrical systems only), or via BS EN 1364-1.

The BS 476-20 standard is also restricted by the 3 metre height of the test furnace. However, under this BS standard, increasing the maximum heights of a system can be based on the ‘Cold State Height’. The cold state height is calculated using structural engineering methods to L/240 @ 200Pascals. (L = Height of wall). Regulatory Requirements

Specific to Approved Document B (England) there is a requirement to use European classifications and fire resistance test methodologies in accordance with BS EN 1363-1 and BS EN 1364-1, which means that the fire state height must be considered. However, Approved Document B (England) currently allows the usage of the BS 476 series, though it should be noted that, following consultation, the full BS 476 series will be removed in 2029. For other nationals, please consult relevant approved documents, technical guidance, and handbooks.

Knauf Approach & Recommendations:

Knauf advise and promote that EN compliance should be followed. That is to say Knauf advise utilising an BS EN 1364-1 fire resistance test and extend the maximum height of a drywall partition system via either BS EN 15254-3, BS EN 1364-1 or via a fire resistance test within a test rig greater than 3m in height.

Projects that wish to use the BS 476 series must gain agreement between the Client, Accountable Persons, Duty Holders, and Local Building Control that the cold state height is an acceptable methodology. For further information on Knauf system types that are applicable to support projects focusing on BS compliance, refer to Knauf Systems Performance Tables (BS compliance).

Product certifications
Material
Gypsum, Metal, Glass mineral wool
Gypsum, Metal, Glass mineral wool
Shape
Rectangle, Other, Square
Rectangle, Other, Square
Width
Bespoke
Bespoke
Height
Bespoke
Bespoke
Warranty description
Lifetime
Lifetime

Specification

System Performance
Sound insulation, Rw (minimum) to BS EN ISO 10140-2 or BS EN ISO 140-3
44 Rw (dB).
44 Rw (dB).
Fire resistance to BS EN 1364-1
EI 30.
EI 30.
Duty rating to BS 5234-2
Medium duty (MD).
Medium duty (MD).
Maximum height - cold state
3400 mm.
3400 mm.
Thickness
77 mm.
77 mm.
Classification data
Framing
Knauf 50 'C' (0.55) at 300 mm centres to suit maximum height. Head channel: Knauf 52 Deep Flange 'U' Channel (0.70) (70 mm deep flange). Floor channel: Knauf 52 'U' Channel (0.55).
Knauf 50 'C' (0.55) at 300 mm centres to suit maximum height. Head channel: Knauf 52 'U' Channel (0.55). Floor channel: Knauf 52 'U' Channel (0.55).
Insulation
25 mm Knauf Insulation Acoustic Roll.
25 mm Knauf Insulation Acoustic Roll.
Linings
1 x 12.5 mm Knauf Soundshield Plus to each side.
1 x 12.5 mm Knauf Soundshield Plus to each side.
Fasteners
25 mm Knauf Performance Plus screws.
25 mm Knauf Performance Plus screws.
Joint treatment
Horizontal joint: Knauf Flat Fixing Plate.
Horizontal joint: Knauf Flat Fixing Plate.
Finish
For paint finishes: System must be taped and jointed using Knauf Joint Filler (Premium) or Knauf Joint Cement Premium and Knauf Joint Tape (Paper). Or alternative Knauf jointing compounds manufactured to EN 13963. Knauf Wallboard Primer applied once taping and jointing completed. Prior to where paint decoration is required. For preparation for decoration of where gypsum plaster skim is required, the outer layer of plasterboard joints is required to be taped and filled, using Knauf Joint Filler (Premium) and Knauf Joint Tape (Paper) meeting quality level 1 in accordance with Eurogypsum - Drywall Jointing & Finishing - Surface quality level classification. For application where gypsum skim finish is required, the Knauf system is to be taped and filled using Knauf jointing compounds. When using Knauf Performance Plus, the applicator of gypsum skim finish is required to check if pre-treatment is required.
For paint finishes: System must be taped and jointed using Knauf Joint Filler (Premium) or Knauf Joint Cement Premium and Knauf Joint Tape (Paper). Or alternative Knauf jointing compounds manufactured to EN 13963. Knauf Wallboard Primer applied once taping and jointing completed. Prior to where paint decoration is required. For preparation for decoration of where gypsum plaster skim is required, the outer layer of plasterboard joints is required to be taped and filled, using Knauf Joint Filler (Premium) and Knauf Joint Tape (Paper) meeting quality level 1 in accordance with Eurogypsum - Drywall Jointing & Finishing - Surface quality level classification. For application where gypsum skim finish is required, the Knauf system is to be taped and filled using Knauf jointing compounds. When using Knauf Performance Plus, the applicator of gypsum skim finish is required to check if pre-treatment is required.
Execution
Consult manufacturer's literature at https://www.knauf.co.uk/our-services/resources
Consult manufacturer's literature at https://www.knauf.co.uk/our-services/resources

Additional properties

Deflection head
For deflection head allowance of up to -25 mm or ±12.5 mm, use 2 x 19 mm Knauf Coreboard fillets.
N/A.
System code
EN-PC-50-055-3-1-12.5-SSP-25., BS-PC-50-055-3-1-12.5-SSP-25.
EN-PC-50-055-3-1-12.5-SSP-25., BS-PC-50-055-3-1-12.5-SSP-25.

Sustainability data

Country of material origin
Spain
Spain
Country of product manufacture
United Kingdom
United Kingdom
Material
Gypsum, Metal, Glass mineral wool
Gypsum, Metal, Glass mineral wool
Recyclability
Individual product EPDs for plasterboard and metal components available at: https://www.knauf.co.uk/our-services/resources/environmental-product-declarations-2
Individual product EPDs for plasterboard and metal components available at: https://www.knauf.co.uk/our-services/resources/environmental-product-declarations-2
Recycled content
12.64 %
12.64 %