Kalzip Standing Seam - Single Skin

Application

Cold roof and wall applications in all shapes, minimum roof pitch 1.5°.

Description

Aluminium standing seam profiles, which meet construction and design requirements to create roofs and facades that combine functionality with aesthetics.


Features and benefits:

  • Suitable for cold roof constructions in all shapes, and pitches from 1.5°, catering for all types of supporting structures.
  • Can be flexibly adjusted to suit the layout, geometry and dimensions of any building.
  • Strong and lightweight.
  • Continuous lengths of 150 m and larger are available when production takes place on-site.
  • A non-penetrative, patented clip attaches the sheets to the substructure. These clips are locked into the seam to ensure smooth thermal cycling of the external sheet over the clip head, whilst facilitating the spanning capacity under high wind loading.
  • The mechanical zipping of the seams produces a load bearing, permanent connection.
  • The weather-tight seam permits any residual moisture to evaporate through the seam, allowing the roof to breathe naturally.
  • Provides a solution for roof penetrations, joints and gable ends.
  • Non-­flammable, and resistant to flying sparks and radiant heat.
  • Can be used as a lightning conductor in accordance with ENV 61024-1.
  • Highly resistant to corrosion.
  • Non-sensitive to UV rays.
  • Resistant to micro-organisms and ‘ageing’.

General information

Shape

Other

Smooth curved, crimp curved, and freeform XT sheets.

Finish

Galvanized

Material

Aluminium

Steel

WarrantyDescription

Ten year

Uniclass

Ss_30_40_65_50 Metal profiled sheet self-supporting roof covering systemsPrimary

CAWS

H31/120 Metal

Specification data - Metal profiled sheet self-supporting roof covering systems Enhanced data

External sheets

-

Material

Kalzip Standing Seam 50/333.

Kalzip Standing Seam 50/429.

Kalzip Standing Seam 65/305.

Kalzip Standing Seam 65/333.

Kalzip Standing Seam 65/400.

Kalzip Standing Seam 65/500.

System accessories

Not required.

Anti-Drumming Membrane (ADM).

Nature roof.

Rooflights.

Solar modules.

Walkways/ Mansafe.

Thickness

0.8 mm.

Tolerance on thickness to be +0.05 mm and –0.025 mm. This is a class 2 thickness tolerance as per BS EN 508-2: 2000.

0.9 mm.

1.0 mm.

1.2 mm.

Finish

Aluminium, AluPlusPatina.

Aluminium, natural stucco embossed.

Aluminium, with a PVDF paint coating.

Aluminium, with an HPC paint coating.

AluPlusZinc.

Show more

Halter clips

Kalzip E-clips.

Steel reinforced polyamide support clips.

Kalzip extruded aluminium ST clips.

With polyamide thermal barrier pads.

Tophat channels

Not required.

Aluminium.

Sub-purlin, 2.0 mm thick aluminium to BS EN 10147, with a proof stress of 180 N/mm², fastened to top-hat profile ‘saddle’ brackets – fabricated from minimum 3.0 mm thick aluminium to BS EN 10147, with a proof stress of 180 N/mm².

Steel.

Sub-purlin, 1.6 mm thick galvanized steel to BS EN 10326, grade S280GD+Z with designation 275 coating, fastened to top-hat profile ‘saddle’ brackets – fabricated from minimum 1.6 mm thick galvanized steel to BS EN 10326, grade S280GD+Z with designation 275 coating.

Third-party certification

British Board of Agrément (BBA) and Globally recognised by the German Zulassung, French Avis Technique and Factory Mutual quality standards.

Environmental information

Contains Red List materials

No

Country of material origin

Germany

Embodied carbon

Refer to EPD certificate.

-

Recycled content

100 %

Recycled aluminium top sheet.

Similar products from Kalzip Ltd

Kalzip Acoustic Deck Roof System – 0.18 U-Value

Kalzip Acoustic Deck Roof System – 0.18 U-Value

Kalzip Acoustic Liner Roof Construction 0.18 U-Value

Kalzip Acoustic Liner Roof Construction 0.18 U-Value

Kalzip Deck Roof System 0.20 U-Value

Kalzip Deck Roof System 0.20 U-Value

Kalzip Liner Roof System 0.15 U-Value

Kalzip Liner Roof System 0.15 U-Value

Kalzip Liner Roof System 0.18 U-Value

Kalzip Liner Roof System 0.18 U-Value

Kalzip Low U-Value Roof System 0.09 W/m²K

Kalzip Low U-Value Roof System 0.09 W/m²K

Kalzip Low U-Value Structural Deck System