Aluminium Kalzip Standing Seam - Liner/Deck Roof System - Standing Seam Roofing and Cladding

Verified by manufacturer 11 days ago

0.20 W/m²K U-Value System (50/333, 50/429, 50/444)

Kalzip Ltd Variant:
Third party certifications:
  • BBA Agrément Certificate

    BBA Agrément Certificate

    Certificate type

  • ISO 9001 Quality Management

    Certificate type

  • EPD

    EPD

    Certificate type

Kalzip standing seam system comprising of aluminium outer skin, E-clips and tophats with lightweight non-combustible insulation, vapour control layer and an inner trapezoidal liner sheet over purlins.

Jump to:
+44 (0)1942 295500 Website

Application

Aluminium Standing Seam system for roof and wall applications.

Description

Kalzip standing seam and metal liner roof system, with a thermal transmittance (U-value) designed to suit the project requirements.


The Kalzip liner roof system is ideal where speed of installation on a project is of utmost importance. A non-fragile walkable Kalzip liner sheet can be quickly installed to provide a weather cover to allow other trades to work below. The remainder of the roofing components can then be installed without affecting the critical path of the construction program.


The Kalzip standing seam roof sheets are supported directly off the roof purlins via the support clips/ halters (aluminium clips or E clips) so therefore act independently of the Kalzip liner sheet.

When lightweight quilt type insulation is used, the external loads (wind suction, snow, access etc.) are transferred direct to the support purlins and not the liner sheet.


Kalzip liners are available as standard in high grade steel or aluminium. Standard finishes include a galvanized, or white enamel finish to suit the internal application. A full range of alternative colours and coatings is also available on request.


All work undertaken should be fully in accordance with Kalzip standard recommendations and by Kalzip approved contractors.

Kalzip sheets to be installed as per cladding manufacturer's instructions.


Features and benefits:

  • The Kalzip liner roof system has the outer Kalzip standing seam roof sheet and the internal Kalzip liner trapezoidal profiled liner sheet laid in the same direction across roof purlins, acting as the primary support. Typical purlin centres would be approximately 1.4–1.8 m.
  • A non-fragile walkable Kalzip liner sheet can be quickly installed to provide a weather cover for those working below. The remainder of the roofing components can then be installed without affecting the critical path of the construction programme.
  • Suitable for a wide range of applications.


For detailed information on load/ span capability, U-values and acoustic variations of the Kalzip liner roof system please contact the Kalzip Technical Team.

General information

Color

Bronze

Gold

Copper

Other

Guidance for specification option:

Available in natural and pre-weathered aluminium, zinc, various bronze and gold patinas, copper, stainless steel and coated to any RAL or BS colour. Refer to product literature for details.

Manufacturer guidance

Various colour options available refer to product literature.

Finish

Galvanized

Textured

Anti-graffiti

Anodized

Coated

Show more

Manufacturer guidance

Various finish options available refer to product literature.

Material

Aluminium

Copper

Stainless steel

Zinc

Steel

Show more

Shape

Other

Guidance for specification option:

Flexible form and shape.

Length

Bespoke

Width

Bespoke

Height

Bespoke

Warranty description

Other

Guidance for specification option:

Various warranty periods are available, consult manufacturer.


15 year

20 year

25 year

30 year

Show more

Uniclass

Ss_30_40_65_50 Metal profiled sheet self-supporting roof covering systemsPrimary

CAWS

H31/10 Metal

H31/120 Metal

Product range

Standing Seam

Specification data - Metal profiled sheet self-supporting roof covering systems

Liner sheets

-

Material

Kalzip Trapezoidal liner sheet in galvanised steel to BS EN 10326. 0.7 mm (Nominal) with Enamel White coating.

Guidance for specification option:

For internal use.

Kalzip Trapezoidal liner sheet in aluminium 0.9 mm Stucco Embossed.

Manufacturer guidance

See also Bearing width below.

Primary fasteners

5.5 mm diameter carbon steel self-drilling fasteners (SD-3-T15-5.5x25).

End and side laps

Side laps to be stitched at maximum 400 mm centres with 4.8 mm diameter carbon steel self-drilling stitching fasteners (SL2-T-4.8x20).

Air and vapour control layer

-

Material

Kalzip VCL Clear - Reinforced virgin polyethylene with 530 MNs/g vapour resistivity.

Guidance for specification option:

Continuity:

  • Lay as work proceeds ensuring continuity. Lap side and end laps of vapour control layer and seal with sealant tape achieving full bond. Seal with sealant tape to perimeter and to pipes, ducts, structural members etc. which abut or pass through achieving a full bond.

Repairs:

  • Carefully check for tears and punctures and seal them with lapped patch of same vapour control layer material and seal with sealing tape along all edges achieving full bond.

Sealing

Seal with one row of sealant tape, not less than 50 mm.

Spacers

Support clips, steel reinforced polyamide Kalzip E-clips type E160 fixed to 30 mm deep steel tophats channels.

Thermal insulation

Kalzip Plus40 Insulation, 205 mm.

Guidance for specification option:

Manufactured with ECOSE™ technology. Finalized insulation thickness dependant on support clip frequency - subject to calculation by Kalzip.

Firestops

To accurately match sheet profile. Adhesive recommended by profile filler manufacturer.

External sheets

-

Material

Kalzip Standing Seam 50/333.

Kalzip Standing Seam 50/429.

Kalzip Standing Seam 50/444.

Manufacturer guidance

Specify Finish separately below.

Primary fasteners

6 mm diameter stainless steel torque controlled fasteners (SDK3-S-377-6.0x45).
Position and frequency to be determined by calculation by Kalzip Technical.

Secondary fixings

Steel tophats to be secured to steel saddles at purlin positions.
Position and frequency to be determined by calculation by Kalzip Technical.

End and side laps

Sheets to be supplied in continuous lengths and mechanically seamed to support clips with Kalzip zipping machine.

Fascia

-

Material

Cappings, closure pieces, flashings, trims, gutters, fillers, spacers, tapes, sealants, fixings, etc, where not specified, to be types recommended by the cladding manufacturer.

Fasteners

Type(s), size(s), material(s) and finish(es) as specified, or in the absence of such specification, as recommended for the purpose by the cladding manufacturer.

Soffit

-

Material

Soffits, where not specified, to be recommended by the cladding manufacturer.

Support

Frequency of soffit supports determined by project engineer.

Gutters

-

Material

Gutters to be sourced through the Kalzip approved installer.
Detailed as per Kalzip standard details and recommendations.

Support

Frequency of gutter supports determined by project engineer.

System accessories

Extruded aluminium alloy (EN AW-6061) gable end hooks.
Extruded aluminium alloy (EN AW-6063) drip angle 40 x 20 mm.
Extruded aluminium alloy (EN AW-6063) flat bar 22 x 6 mm.
Extruded aluminium alloy (EN AW-6063) gable end channel.
Extruded aluminium alloy (EN AW-6063) tolerance gable clip extrusion.
Fabricated aluminium alloy (EN AW-3004) flashings.
Fabricated aluminium alloy (EN AW-3004) ridge closures (KZ 65/400).
Fabricated welded soaker units.
Kalzip profile eaves fillers.
Kalzip profile ridge fillers.

Guidance for specification option:

Fabricated aluminium alloy (EN AW-3004) flashings and Fabricated welded soaker units:

  • Material and finish as per cladding sheets or as per project requirements - consult manufacturer for details.

Thermal transmittance (U-Value)

0.20 W/m²K.

Bearing width

58 mm (minimum).

Type

Kalzip profiled fillers - Closed cell cross-linked polyethylene with a minimum density of 30 kg/m³.

Thickness

Guidance for specification option:

30 mm minimum.

Locate where shown on drawings and wherever necessary to close off corrugation cavities from the outside and inside of the building. Ensuring a tight fit, leaving no gaps.

Finish

Aluminium, AluPlusPatina.

Aluminium, natural stucco embossed.

Aluminium, with a PVDF paint coating.

Aluminium, with an HPC paint coating.

AluPlusZinc.

Show more

Manufacturer guidance

External sheets finish only.

Shape

Guidance for specification option:

Insert requirements to suit project requirements.

Dimensions

Guidance for specification option:

Insert requirements to suit project requirements.

Third-party certification

British Board of Agrément Certification No. 98/3481.
Institute fur Bautechnic Zulassungbescheid N R 14.1-181.

Movement joints

Leave space between sheets to coincide with structural movement joints. Fix weathertight movement joint cover to sheets on one side only. Movement joint cover detail to be as per Kalzip Ltd recommended detail KZ-0-MISC-K-8-006.

Fixing method

Fixing sheets generally:
Remove all drilling swarf, dust, debris and any other foreign matter before finally fixing sheets into position. Protect sheets adequately during fixing and up to practical completion against mechanical damage, corrosion and disfigurement. Rectify any defects as quickly as practicable to minimise damage and nuisance. Install fasteners to correct tightness using any special tools recommended by the manufacturer.

Installation

Kalzip sheets to be installed by mechanically seaming sheets to support clips with Kalzip zipping machine.
Kalzip sheets to be installed as per cladding manufacturer's instructions, British Board of Agrément Certification No. 98/3481 and Institute fur Bautechnic Zulassungbescheid N R 14.1-181.
Only roofing contractors who are members of Kalzip Ltd’ approved roofing contractors programme should be employed to install Kalzip roofing.
Approved roofing contractor is to provide on site fully trained.

Solar system

Not required.

Kalzip DICONAL mounting system mechanically fixed to Kalzip standing seam profiles without penetrating the roofing material. Fixing method to comply with the manufacturer’s recommendations, ensuring the integrity of the roofing system and compatibility with project-specific requirements.

Guidance for specification option:

Please contact Kalzip Technical for layout and component breakdown.

Sustainability data

Contains Red List materials

No

Country of material origin

Germany

Country of product manufacture

United Kingdom

Manufacturing plant location

Material

Aluminium

Copper

Stainless steel

Zinc

Steel

Show more

Embodied carbon

A1-A3 (production stage) as defined in BS EN 15804

9.61 kg CO₂ eq/kg

Manufacturer guidance

Refer to EPD certificate.

Recyclability

Excellent

Recycled content

As defined in clause 7.8 of BS EN ISO 14021

100 %

Guidance for specification option:

 Recycled aluminium top sheet.

Expected Life

40 year

Third party certifications

Third party certifications

BBA Agrément Certificate

BBA Agrément Certificate

Kalzip 98/3481 Single Skin System Product Sheet 3

BBA Agrément Certificate

BBA Agrément Certificate

Kalzip 98/3481 Liner Roof System Product Sheet 1

ISO 9001 Quality Management

ISO 9001 Quality Management

Kalzip ISO 9001

EPD

EPD

Kalzip Standing Seam EPD

Literature

Kalzip systems

Kalzip systems

Kalzip case studies

Kalzip case studies

98/3481 Kalzip secret fix roof systems

98/3481 Kalzip secret fix roof systems

Case studies

Kelvin Hall, Glasgow

Kelvin Hall, Glasgow

South Bristol Skills Academy

South Bristol Skills Academy

SSE Hydro Arena, Glasgow

SSE Hydro Arena, Glasgow

Similar products from Kalzip Ltd

Aluminium Kalzip Standing Seam - Structural Deck Roof System - Standing Seam Roofing and Cladding

Aluminium Kalzip Standing Seam - Structural Deck Roof System - Standing Seam Roofing and Cladding

Kalzip Low U-Value Roof System 0.09 W/m²K

Kalzip Low U-Value Roof System 0.09 W/m²K

Kalzip Low U-Value Structural Deck System - Aluminium standing seam system

Kalzip Low U-Value Structural Deck System - Aluminium standing seam system

Kalzip Standing Seam - Acoustic Deck Roof System

Kalzip Standing Seam - Acoustic Deck Roof System

Kalzip Standing Seam - Deck Roof System 0.20 U-Value

Kalzip Standing Seam - Deck Roof System 0.20 U-Value

Kalzip Standing Seam - Single Skin - Aluminium standing seam profiles.

Kalzip Standing Seam - Single Skin - Aluminium standing seam profiles.