NBS Source
Kalzip Acoustic Deck Roof System – 0.18 U-Value

Kalzip Acoustic Deck Roof System – 0.18 U-Value

Kalzip Ltd Third party certifications:
  • BBA Agrément Certificate

    BBA Agrément Certificate

    Certificate type

Metal profiled acoustic deck roof system, with a thermal transmittance (U-Value) of 0.18 W/m²K.

Jump to:
+44 (0)1942 295500 www.kalzip.com

Application

For roof and wall applications.

Description

Metal profiled acoustic deck roof system, with a thermal transmittance (U-Value) of 0.18 W/m²K.


All work undertaken should be fully in accordance with Kalzip standard recommendations and by Kalzip approved welding contractors. Site welding must be carried out fully in accordance with Approved Welding Procedure Specification ASW/TIG/001 Rev ‘B’ 1997 as defined in BS EN ISO 9606-2 for material gauges between 0.8–3 mm thickness. Site welding operatives must be certified to BS EN ISO 9606-2 standard for material gauges between 0.8–3 mm thickness. The weld test procedure shall be in accordance with BS EN ISO 15614-2: 2005.


Kalzip sheets to be installed as per cladding manufacturer's instructions.


Features and benefits:

  • Perforated decking helps to improve the acoustic conditions within a building by helping to optimise reverberation times.
  • The deck system is a variation of the standard liner system. A higher structural grade of steel is used to allow the clip rails to be positioned away from the main steelwork.
  • Quick installation.
  • Suitable for a wide range of applications.

General information

Finish

Galvanized

Material

Aluminium

Steel

Mineral wool

Polyethylene

WarrantyDescription

Ten year

Uniclass

Ss_30_40_65_50 Metal profiled sheet self-supporting roof covering systemsPrimary

CAWS

H31/10 Metal

H31/120 Metal

Specification data - Metal profiled sheet self-supporting roof covering systems Enhanced data

Liner sheets

-

Material

Kalzip Structural Decking Sheet KSD100 Web Perforated.

Primary fasteners

5.5 mm diameter carbon steel self-drilling fasteners.

(SD-8-T15-5.5x25).

One fastener(s) to be installed in every valley at each sheet support.

End and side laps

Standard side lap arrangement.

Air and vapour control layer

-

Material

Kalzip VCL Clear - Reinforced virgin polyethylene with 530 MNs/g vapour resistivity.

Sealing

Seal with one row of sealant tape, not less than 50 mm.

Acoustic insulation

Kalzip Acoustic Rockfibre Slab.

 (Tissue faced optional). Manufactured with ECOSE™ Technology.

Thermal insulation

Kalzip Insulation Quilt Type 1.

Manufactured with ECOSE™ Technology.

External sheets

-

Material

Aluminium Standing Seam 65/400.

Primary fasteners

6 mm diameter stainless steel torque controlled fasteners (SDK3-S-377-6.0x45). Two fasteners per E-clip, positioned diagonally opposite in the holes of the base of the clip.

End and side laps

Mechanically seamed over head of support clips with a Kalzip 'zipping' machine.

System accessories

Not required.

Extruded aluminium alloy (EN AW-6061) gable end hooks.

Extruded aluminium alloy (EN AW-6063) drip angle 40 x 20 mm.

Extruded aluminium alloy (EN AW-6063) flat bar 22 x 6 mm.

Extruded aluminium alloy (EN AW-6063) gable end channel.

Extruded aluminium alloy (EN AW-6063) tolerance gable clip extrusion.

Fabricated aluminium alloy (EN AW-3004) flashings.

Material and finish as per cladding sheets or as per project requirements - consult manufacturer for details.

Fabricated aluminium alloy (EN AW-3004) ridge closures (KZ 65/400).

Fabricated welded soaker units.

Material and finish as per cladding sheets or as per project requirements - consult manufacturer for details.

Kalzip profile eaves fillers (KZ 65/400).

Kalzip profile ridge fillers (KZ 65/400)..

Thermal transmittance (U-Value)

0.18 W/m²K.

Pitch

1.5° (minimum).

Finish

Aluminium, AluPlusPatina.

Aluminium, natural stucco embossed.

Aluminium, with a PVDF paint coating.

Aluminium, with an HPC paint coating.

AluPlusZinc.

Show more

Sub-purlins

Minimum one fastener(s) at each top-hat/ deck crown connection, alternating each side/ both sides.

Thermal insulation

Mineral wool insulation, manufactured in accordance with BS EN 13162.

Profile fillers

Black closed cell cross-linked polyethylene with a minimum density of 30 kg/m³.

Thickness

30 mm (minimum).

 Consult manufacturer and insert requirements.

Third-party certification

British Board of Agrément Certification No. 98/3481 and Institute fur Bautechnic Zulassungbescheid N R 14.1-181.

Environmental information

Contains Red List materials

No

Country of material origin

Germany

Embodied carbon

Refer to EPD certificate.

-

Recycled content

100 %

 Recycled aluminium top sheet.

Literature

Kalzip systems

Kalzip systems

Third party certifications

BBA Agrément Certificate

BBA Agrément Certificate

Kalzip 98/3481 Single Skin System Product Sheet 3

Similar products from Kalzip Ltd

Kalzip Acoustic Liner Roof Construction 0.18 U-Value

Kalzip Acoustic Liner Roof Construction 0.18 U-Value

Kalzip Deck Roof System 0.20 U-Value

Kalzip Deck Roof System 0.20 U-Value

Kalzip Liner Roof System 0.15 U-Value

Kalzip Liner Roof System 0.15 U-Value

Kalzip Liner Roof System 0.18 U-Value

Kalzip Liner Roof System 0.18 U-Value

Kalzip Low U-Value Roof System 0.09 W/m²K

Kalzip Low U-Value Roof System 0.09 W/m²K

Kalzip Low U-Value Structural Deck System

Kalzip Low U-Value Structural Deck System

Kalzip Standing Seam - Single Skin

Kalzip Standing Seam - Single Skin