Verified by manufacturer 6 months ago
Therm+ 56 A-I aluminium
Kalwall diffused natural daylight panels glazed into a Raico Therm + aluminium, steel or timber curtain wall.
Suitable for single-story applications to mid-rise construction.
Raico Therm+ curtain walling systems with 70mm Kalwall panels give you all the features and benefits of a Kalwall panel with the added benefits of a German engineered stick curtain wall system.
The Raico Therm+ curtain walling system is available in aluminium, timber and steel, or a combination of any of these. There is a choice of 50 mm, 56 mm and 76 mm sight-line widths. NB: Aluminium is only available in 50 mm and 56 mm. All other frames are available in all three sight-lines.
Kalwall panels are a highly insulating, diffuse light-transmitting building panel system. These structural sandwich panels are formed by permanently bonding two specially formulated translucent Fibreglass Reinforced Polymer (FRP) faces to a Grid Core constructed of interlocking aluminium or thermally-broken composite I beams.
Panels are factory prefabricated to the exact size and configuration for each project. Utilising either light-transmitting fibreglass ‘batts’ or aerogel as Translucent Insulation (TI), insulated panels can achieve a maximum of 0.28 W/m²K.
Kalwall panel standards widths are 1224 mm (4ft), 1520 mm (5ft) Maximum width is 1520 mm (5ft). Panel lengths between 914 mm and 6096 mm. Note: please check spans with Structura UK Ltd.
As a whole, Raico Therm+ curtain walling systems with Kalwall panels, create a highly adaptable, progressive stick curtain wall façade which can achieve Passivhaus performance standards. This system helps you, the architect, seamlessly transition between vision glass, operable windows, doors and can even support signage or Brise Soleil systems; effectively treating a Kalwall panel as if it were a double glazed unit into a curtain wall façade.
Features and benefits:
Kalwall is not a glazing panel but rather a structural sandwich panel with outstanding load capacity and structural integrity that polycarbonate systems and insulated glass units (IGU) simply cannot match.
With a high strength-to-weight ratio, Kalwall panels are both strong and lightweight. This makes the installation process easier and reduces extraneous structural support framing, saving both time and money. All Kalwall systems are very low maintenance. The panel’s FRP faces have self cleaning properties, are resistant to dirt and particulate build-up, and can handle harsh chemical and environmental exposure.
The panels block harmful UV-A and UV-B rays while transmitting the full spectrum of visible light for perfect colour rendition within interiors. With a wide range of translucent insulation options, Kalwall’s thermal performance reduces HVAC heating and cooling loads while harvesting daylight to cut artificial lighting usage.
Fibreglass Reinforced Polymer (FRP) Faces:
Kalwall has developed a full line of high performance FRP face sheets including the latest generation of Super Weathering (SW) formulations that are unrivalled in the industry. Along with a variety of high performance options, Kalwall offers both standard and optional colours and finishes in order to provide designers with more flexibility. Translucent White and Crystal FRP face sheets are standard. The four Kal-tints are optional. Optional FRP finishes are available for interior face sheets only.
Color | White Grey Blue Red Green |
Finish | Anodized Powder-coated Mill |
Material | Aluminium Steel Timber Glass Glass Fibre |
Shape | Rectangle Square Trapezoid |
Length | Bespoke Manufacturer guidancePanel lengths between 914 and 6096 mm. Please check spans with Structura UK Ltd. |
Width | 1224 mm 1520 mm Bespoke Manufacturer guidanceKalwall panel standards widths are 1224 mm (4ft), 1520 mm (5ft) Maximum width is 1520 mm (5ft) |
Height | 70 mm |
Uniclass | |
CAWS | H11/110 Curtain walling |
Framing | |
Frame members | Raico Therm+ 56 A-I aluminium curtain wall frame. |
Frame accessories | Manufacturer guidanceA wide range of cover profiles are available, including bespoke. Consult manufacturer's literature and insert requirements. |
Cladding units | |
Glass units | Annealed glass sheets.Insulated glass units (IGUs).Laminated glass sheets.Not required.Manufacturer guidanceGlass units that can be used within the system windows. Supplied by others (specific glazing manufacturer); consult manufacturer and insert requirements. |
Panels and facings | |
Material | Kalwall fibre-reinforced polymer (FRP) structural composite sandwich panels. |
Thermal insulation | None.Aerogel.Glass fibre. |
System accessories | None.Opening window units.Fixed window units.Solar protection fastening.Fixture unit.Fastening bracket.Scaffolding fixation.Canopy fastening.Suction disc. |
Profile | Rectangular, 25 mm depth. Rectangular, 50 mm depth. Rectangular, 75 mm depth. Rectangular, 100 mm depth. Rectangular, 125 mm depth. |
Glazed panel | Flat. Kalwall 70 mm insulated panels. Glass. Guidance for specification option: As per glass units above. |
Colour/ Finish (external) | White SW-E. Guidance for specification option: Standard. Crystal SW-E. |
Colour/ Finish (internal) | White B-3C. Guidance for specification option: Standard. |
Thickness | 70 mm. |
Configuration | Ladder, 200 mm. Guidance for specification option: Ladder Grid Cores are optional for facades only. Nominal spacings of 203 and 254 mm are standard. Custom widths between 101 and 254 mm are also available. Depending on panel size and orientation, a cross mullion may be required. Panel spans will vary with different grid cores and spacings. Consult the factory for information based on project requirements. Kalcurve and Aerogel options are not available. Ladder, 250 mm. Reverse Shoji, 500 x 200 mm. Reverse Shoji, 500 x 300 mm. Reverse Shoji, 600 x 300 mm. |
Reaction to fire | To EN 13501-1, External facesheet: B-S2,d0; Internal facesheet: B-s2,d0. |
SurfaceSpreadOfFlame | To BS 476-7, Interior face: UK Class 1(0); Exterior face: UK class 2. |
Fire propagation to BS 476-6 | Fire propagation index (I) 5.1. Sub-index (i1) 1.5. |
Air permeability | To EN 12152, Class A4. |
Watertightness | To EN 12154, Class 9A. |
Wind resistance | To EN 13116, Class 6. |
Certification | Not required. Passive house certified standard required. |
Security | Not required. Burglar resistance to DIN EN 1627, RC 2. Burglar resistance to DIN EN 1627, RC 3. |
Connectors | T-connector. |
Insulation | 0.28 W/m²K. 0.56 W/m²K. 0.78 W/m²K. 1.25 W/m²K. 2.57 W/m²K. Manufacturer guidanceNote insulation value choice will determine light transmission and solar factor values (as per guidance). |
Light transmission | 5% (White SW-E)/ 6% (Crystal SW-E). Guidance for specification option: 0.56 W/m²K. 8% (White SW-E)/ 9% (Crystal SW-E). Guidance for specification option: 0.78 W/m²K. 12% (White SW-E)/ 15% (Crystal SW-E). Guidance for specification option: 0.28 W/m²K. 14% (White SW-E)/ 20% (Crystal SW-E). Guidance for specification option: 1.25 W/m²K. 20% (White SW-E)/ 30% (Crystal SW-E). Guidance for specification option: 2.57 W/m²K. |
Solar heat gain coefficient | 0.07 (White SW-E/ Crystal SW-E). Guidance for specification option: 0.56 W/m²K. 0.10 (White SW-E)/ 0.12 (Crystal SW-E). Guidance for specification option: 0.78 W/m²K. 0.13 (White SW-E)/ 0.18 (Crystal SW-E). Guidance for specification option: 0.28 W/m²K. 0.16 (White SW-E)/ 0.19 (Crystal SW-E). Guidance for specification option: 1.25 W/m²K. 0.31 (White SW-E)/ 0.38 (Crystal SW-E). Guidance for specification option: 2.57 W/m²K. |
Contains Red List materials | No |
Embodied carbonA1-A3 (production stage) as defined in BS EN 15804 | Manufacturer guidanceEPD's can be downloaded from NBS for both wall and roof systems |
Recyclability | Can be recycled - See guidance Manufacturer guidanceKalwall has a design life of 25 years with minimal maintenance. Made from Aluminium and FRP it is chemical and rot resistant. UV stable to full body depth, it will not yellow. The FRP facesheets are also engineered to incorporate a glass erosion barrier, preventing fibre bloom. The Aluminium frame is easily recycled, the FRP sheets can be separated and ground to a powder and added back into GRP production. |
Kalwall - Backlighting
Kalwall - Daylight modelling
Kalwall - Diffused daylighting
Kalwall - Durability
Kalwall - LEED v3 benefits
Kalwall - LEED v4 benefits
Kalwall - Low Maintenance
Kalwall - Museum Quality Daylighting
Kalwall - Product Guide - Kalwall and Raico Therm+ Curtain Wall
Kalwall - Product Guide - Overview of Kalwall
Kalwall - Product Guide - Retrofit and renovations
Kalwall - Protection and Security
Kalwall - Reduced Glare
Kalwall - Retrofit and renovation
Kalwall - Sector Report - Education
Kalwall - Sector Report - Sport & Leisure
Kalwall - Sector Report - Transportation
Kalwall - Solar Control
Kalwall - Thermal Performance
White Paper - Creating A Safer Built Environment
White Paper - Four Challenges of a Retrofit Project