NBS Source
I'm a manufacturer

Application

The product should be laid bonded. It is recommended for use in heavily trafficked car park areas to receive a Deckshield finish.


IMPORTANT: All specification information must be checked against the individual site requirements. Flowcrete advises that specifications are confirmed with their technical experts.

Description

An early drying, high strength, semi-dry cementitious screed and incorporating proprietary additives. Isocrete K-Screed HDP should be laid and bonded.


Features and benefits:

  • Rapid installation and cure.
  • High-strength and resistance to construction traffic.
  • Suitable with underfloor heating.
  • Heavy duty screed base for use in bonded systems to receive the Flowcrete Deckshield system.

General information

Material

Cement

Warranty description

Ten year

Uniclass

Pr_35_31_06_64 Polymer-modified levelling screed mixesPrimary

CAWS

M10/130 Proprietary quick drying levelling screeds

M10/7 Proprietary quick drying levelling screeds

Specification data - Polymer-modified levelling screed mixes

Cement

Portland Cement CEM 1 52.5N.

Cement additions

K screed additive, isopol SBR.

Coarse aggregate

2–5 mm granite chippings.

Fine aggregate

Sharp sand.

Polymer modification

Isopol SBR.

Mix

1:3.

Additives

K screed additive, isopol SBR.

Bond strength

>2 N/mm².

BRE test

Category A.

CompressiveStrength

>45 N/mm².

Cure time

24 hours (light traffic), 7 days (full traffic), 3 days minimum
(curing under polythene).

Density

2200 kg/m³.

Minimum thickness

Bonded: 15 mm.

Reinforcement options

Optional isocrete PP fibre reinforcement.

Thickness range

15–100+ mm.

Execution

Trowelled or floated.

BIM objects

BOS

NBS BIM Object Standard

This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.

Find out more about the NBS BIM Object Standard.

Platform Compatible Version
Revit
-

3

IFC
-

2