In Ground Power Unit - KIGU600/600
Application

Suitable for trading areas, open air areas with events and exhibitions where temporary power is required. The product is also suitable for traffic light control, CCTV control and telecoms.

It is necessary to ensure a connection to the drainage system. Ensure C35/45 grade concrete all around and underneath.

Description

A paver in ground power unit. This model (Type 3) has a 600 x 600 mm top recessed cover.

It contains an IP 67 electrical panel that holds a combination of three or four sockets either 16A, 32A single phase or three phase plus an additional data panel with 1 to 4 RJ45 sockets.

For added safety the lids are closed during operation. The hinged recessed cover ensures the units are unobtrusive when not in-use. The unit is manufactured in accordance with FACTA and BS EN 124 standards.

The covers are suitable for all types of paving blocks and are manufactured to meet required loadings. They are fabricated in 3, 4, 6 and 8 mm stainless steel as standard. The paving blocks are placed directly adjacent to the frame and bedded using an epoxy or polymer modifier mortar.

Features and benefits:

  • The unit incorporates gas rams.
  • Two IP67 rated sockets as standard.
  • Slam lock.
  • Excellent for market trading areas.
  • Alternative knockouts to 125 mm diameter cable duct.
  • Drain point with ant rodent mesh.

Applications:

Suitable for trading areas, open air areas with events and exhibitions where temporary power is required. The product is also suitable for traffic light control, CCTV control and telecoms.

It is necessary to ensure a connection to the drainage system. Ensure C35/45 grade concrete all around and underneath.

General information

Material

1.4301 (304) stainless steel

1.4401 (316) stainless steel

Galvanized carbon steel to 140 micron

Minimum for Middle East projects.

Galvanized carbon steel to BS EN ISO 1461

Features

Gas rams, slam lock, four sockets as standard plus RJ45 data point, multiple versions available

Shape

Square

Size

600 x 600 x 450 mm

Uniclass 2015

Pr_65_52_01_02 Access covers and framesPrimary

CAWS

P31/370 Access covers/ gratings for

Specification data - Access covers and frames

Product Reference

In Ground Power Unit

Type

KIGU-600/600/450 – Type 3

Material

1.4301 (304) stainless steel

1.4401 (316) stainless steel

Galvanized carbon steel to 140 micron

Minimum for Middle East projects.

Galvanized carbon steel to BS EN ISO 1461

Loading

BS EN 124 A15

Slow moving wheel load: 0.6 tonnes. Kent safety test (unfilled): 1.5 tonnes.

BS EN 124 B125

Slow moving wheel load: 5 tonnes. Kent safety test (unfilled): 12.5 tonnes.

BS EN 124 C250

Slow moving wheel load: 6.5 tonnes. Kent safety test (unfilled): 25 tonnes.

BS EN 124 D400

Slow moving wheel load: 11 tonnes. Kent safety test (unfilled): 40 tonnes.

FACTA A

Slow moving wheel load: 0.6 tonnes. Kent safety test (unfilled): 0.8 tonnes.

FACTA AA

Slow moving wheel load: 1.5 tonnes. Kent safety test (unfilled): 3.1 tonnes.

FACTA AAA

Slow moving wheel load: 2.5 tonnes. Kent safety test (unfilled): 5.2 tonnes.

FACTA B

Slow moving wheel load: 5 tonnes. Kent safety test (unfilled): 10.1 tonnes.

FACTA C

Slow moving wheel load: 6.5 tonnes. Kent safety test (unfilled): 13.2 tonnes.

FACTA D

Slow moving wheel load: 11 tonnes. Kent safety test (unfilled): 22 tonnes.

Operation

Closed use

Open use

Power sockets

EP005

Single phase: Two 16 A and One 32 A.

EP006

Single phase: Two 16 A and Two 32 A.

EP008

Single phase: Three 16 A and One 32 A.

EP009

Single phase: Three 16 A.

EP010

Single phase: Three 32 A.

EP011

Single phase: Four 16 A.

EP012

Single phase: One 16 A and Two 32 A.

Accessories

None

DP001

RJ45 connection.

DP002

Twin RJ45 connections.

DP003

Three RJ45 connections.

DP004

Four RJ45 connections.

Dual XLR Connection

XLR Connection

Standard product features

Visible frame:

600 x 450 mm.

Unit depth:

450 mm

Tray depth:

125 mm.

Residual current circuit breaker with over current protection (RCBO):

The range designed to ensure efficiency and protection. The RCBOs supplied comes standard with every Kent IGU to ensure safety when working with electrical Components and are all IP67 rated.

Product Options

Power sockets:

- Single phase sockets:

All single phase Garo sockets are three pin IP67 related which can submerged in water for up to 30 minutes.

  • 16 A 200/ 250 V.
  • 32 A 200/ 250 V.
  • 63 A 200/ 250 V.

- Three phase sockets (available upon request):

All three phase Garo sockets are five pin IP67 related which can submerged in water for up to 30 minutes.

  • 16 A 240/ 415 V.
  • 32 A 380 V.
  • 63 A 230/400 V.

Accessories:

  • RJ45 Datapoints: RJ45 is a type of connector commonly used for Ethernet networking. These sockets are particularly useful for temporary vendors who can connect to use their card payment system (e.g. Visa Machine). These sockets when closed are IP67 rated.
  • XLR connection: The XLR connector is a style of electrical connector, primarily found on professional audio, video, and stage lighting equipment. These connectors are generally supplied three pin as standard and when closed are IP67 rated.

Digital objects
PlatformCompatibleVersionCertified to
Revit
Revit 2017 1 2.0
IFC
- 1 2.0