Verified by manufacturer 7 months ago
psi-FAST 384 mm
Certificate of Compliance
Certificate type
Certificate of Compliance
Certificate type
EN 13501-2
Certificate type
Fire Safety Certification
Certificate type
fire-resistant, acoustic, structural and thermal wall panel.
Suitable for loadbearing external walls, external envelope wrap, external infill, internal partitions and compartments.
Sustainable fabric first, Low Upfront Carbon, Net Zero Carbon in Operation and Passivhaus designs.
Suitable for applications within the public and private education, healthcare, life science, leisure, commercial and residential sectors.
Compatible with all membranes, lining boards. Tapes and sealants suitable for the project.
Not suitable for direct applied external or internal wet render/ plaster.
Prefabricated wall panel with intrinsic fire, acoustic, structural and thermal performance.
Innovaré Offsite’s award-winning, patented i-FAST structural timber panel system which uses offers reduce U-values and psi-values whilst underpinned by rigorous fire testing to BS EN 1365-1 (loaded fire resistance testing) to a height of 5m.
Manufactured offsite in a controlled environment i-FAST offers the capacity to include Pre-Manufactured Value (PMV) elements such as factory-fitted vapour control, windows and cladding.
The panel can be specified independently of without reliance on fire performance of ancillary cladding, membranes and linings.
Can be used as part of a Full Structure, Infill or Wrap Building structural strategy.
Please consult manufacturer for details.
Features and benefits:
- Fire:
- Acoustics:
- Structure:
- Thermal:
Consists of the following system components:
Color | Other |
Finish | Other |
Material | Fibre cement Timber Stonewool |
Shape | Rectangle |
Length | 7200 mm Bespoke |
Width | 208 mm 259 mm 384 mm 300 mm Manufacturer guidanceThickness. |
Height | Bespoke 3600 mm |
Warranty description | 60 year |
Uniclass | |
CAWS | G20/348 Structural insulated wall panels |
Classification data | |
Timber framing members | Solid softwood timber. Glue laminated softwood timber. |
Sheets and boards | RCM Multipurpose Board. Knauf Rocksilk. Rothoblaas Traspir 250 breather membrane. Protect VC foil. |
Assembly fasteners | 3.1 mm diameter, 90 mm round wire framing nails. 2.8 mm diameter, 50 mm sheathing nails. |
Anchors to concrete and masonry | |
Type of anchor | Starfix framing screw. |
Fire resistance (to EN 13164/ EN 1365-1) | To BS EN 1365-1, to 5m loaded height. Guidance for specification option: Standard BS EN testing is to 3m in height. iFast is tested to 5m loaded height in a specialist, UKAS Accredited facility located in the UAE. Please consult manufacturer for more details. |
Fire performance | To BS EN 1365-1, REI 30 minutes. Guidance for specification option: Standard BS EN testing is to 3m in height. iFast is tested to 5m loaded height in a specialist, UKAS Accredited facility located in the UAE. Please consult manufacturer for more details. To BS EN 1365-1, REI 60 minutes. Guidance for specification option: Standard BS EN testing is to 3m in height. iFast is tested to 5m loaded height in a specialist, UKAS Accredited facility located in the UAE. Please consult manufacturer for more details. To BS EN 1365-1, REI 90 minutes. Guidance for specification option: Standard BS EN testing is to 3m in height. iFast is tested to 5m loaded height in a specialist, UKAS Accredited facility located in the UAE. Please consult manufacturer for more details. Manufacturer guidanceStandalone load bearing fire resistance and integrity. |
Size: | 3600 x 7200 mm (h x l). |
Thickness: | 384 mm. |
Acoustic performance | 56 Rw dB. Manufacturer guidance
|
Thermal performance | 0.11 W/m²·K. Guidance for specification option: Limited repeating thermal bridges from staggered stud. U-values from 0.23–0.11 W/m²·K depending on cladding and lining. Enhanced airtight performance from factory fitted VCL. |
Contains Red List materials | No |
Country of material origin | Europe |
Country of product manufacture | United Kingdom |
Manufacturing plant location | |
Material | Fibre cement Timber Stonewool |
Recyclability | Designing for Disassembly Transparency – Innovaré Offsite building systems are visible and with O&M manuals are easy to identify. Regularity – Innovaré Offsite building systems and materials that are similar throughout a building and laid out in regular, repeating patterns. Simplicity – Innovaré Offsite building systems and interconnections that are simple to understand, with a limited number of different material types and component sizes. Limited number of components – it is easier to dismantle structures that are composed of a smaller number of larger timber members than a larger number of smaller timber members. Conversely, in cases where deconstruction will likely be undertaken using primarily hand-labor rather than large machinery, it may be appropriate to design with smaller, lighter members. Easily separable materials – i-FAST or psi-FAST materials should be easily separable into reusable components. Mechanical fasteners are preferable to adhesives. Composite materials can cause difficulty unless the composite assembly has reuse value as an assembly. |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 0 % |
Expected Life | 60 year |
Abbey View Primary School
Aspire School
Broxbourne School, Broxbourne, Hertfordshire - Education
Kingfisher Court - Health
Linmere Visitors Centre - Leisure
Red Kite Academy - Education
Rockwood Academy - Education
Staffordshire University Nursery & Forest School
St. Mary's Catholic Voluntary Primary School - Education
Thames Park Secondary School
The Valley School - Education
Three Rivers Academy
Turves Green School - Education
Unity Campus, Sawston, Cambridgeshire
West Coventry Academy
Ysgol Gynradd Gymraeg Llyn y Forwyn - Education
Ysgol Newydd Corn Hir