Hygiene Meditec A or E
Application

Intended for environments where disinfection and/ or cleaning is required on a regular basis. This system is recommended for dry environments. Examples of applications: consulting rooms in healthcare premises.

Description

Ecophon Hygiene Meditec C1 is a wall-to-wall, sound-absorbing ceiling system intended for environments where disinfection and/ or cleaning is required on a regular basis. This system is recommended for dry environments. Examples of applications: consulting rooms in healthcare premises. The system is classified B1 and B5 for zone 4 according to standard NF S 90-351, and clean room-classified according to ISO 4.

The weight of the system is approximately 2.5 kg/m².

Features and benefits:

  • The system consists of Ecophon Meditec tiles, which have a core of high-density glass wool and a painted cleanable Akutex™ TH surface. The rear side of the tile is covered with glass tissue. The edges are primed.
  • The supporting structure is an exposed Ecophon Connect T24 grid of galvanized steel.
  • The tiles should be secured to the grid with Connect Universal clips in order to withstand pressure during cleaning, and to minimize dirt traps.

General information

Finish

Galvanized

Akutex TH – a painted cleanable surface. The surface allows almost 100% of the sound energy to penetrate into and be absorbed by the glass wool

Color

White

White 010 to white 500 (nearest NCS colour sample S 0500-N, 84% light reflectance).

Features

With exposed or recessed visible grid and tegular edge design. Wall-to-wall, sound-absorbing ceiling system, classified B1 and B5 for zone 4 according to standard NF S 90-351, and clean room-classified according to ISO 4

Material

High-density glass wool

Steel

Shape

Square

Rectangular

Size

600 x 600 mm

1200 x 600 mm

1600 x 600 mm

1800 x 600 mm

2000 x 600 mm

Show more

WarrantyDescription

Uniclass 2015

Ss_30_25_22_90 Unit/ modular suspended ceiling systemsPrimary

CAWS

K40/10 Suspended ceilings

K40/105 Suspended ceiling system

K40/115 Unit/ modular suspended ceiling system

K40/265 Infill units

K45/12 Existing suspended ceiling system

K45/120 Existing suspended ceiling system

K45/13 Suspended ceiling system alterations

K45/130 Unit-suspended ceiling system alterations

K45/160 Board-suspended ceiling system alterations

Specification data - Unit/ modular suspended ceiling systems Enhanced data

Ceiling support

Interlocking Connect™ T24 C1 grid.

Interlocking Connect™ T24 C3 grid.

Support fasteners

Adjustable hangers/ wire.

150 mm overall system depth.

Direct-fixing brackets.

50 mm overall system depth.

Ceiling units

High-density glass wool tiles.

System accessories

None.

Connect™ Bridging Profile and Clip.

For luminaire integration in panels.

Connect™ E-Plug.

To cover gap profile and shadowline trim.

Connect™ Inspection Panel C1.

Connect™ Inspection Hatch C3.

Connect™ Lighting Clip.

Connect™ Universal Clip.

Connect™ Ventilation Grill.

Edge Sealant.

Product Reference

Hygiene Meditec A

With exposed grid, primed edges.

Hygiene Meditec A

With exposed grid, primed edges.

Size (l x w)

600 x 600 mm.

1200 x 600 mm.

1600 x 600 mm.

XL tile, not available for Hygiene Meditec E.

1800 x 600 mm.

XL tile, not available for Hygiene Meditec E.

2000 x 600 mm.

XL tile, not available for Hygiene Meditec E.

Show more

Thickness

15 mm.

Grid colour

Black 01 matt.

For C1 only.

Grey 01 metallic.

For C1 only.

White 01.

Trim

Not required.

Connect™ A.

Connect™ Angle Trim C1.

Connect™ Channel Trim C1.

Connect™ Column Trim C1.

Show more

Weight

2.5 kg/m².

approximate, including Connect grid system

Demounting depth (minimum)

100 mm without clips, 150 mm with clips.

Indoor climate

Certified in accordance with Indoor Climate Labelling. Recommended by the Swedish Asthma and Allergy Association. Certified as A+ by French VOC. Emission classification of building materials: M1. Clean room-classified according to ISO 5. Classified B5 for zone 4 according to standard NF S 90-351.

Moisture resistance

The tiles withstand a permanent ambient RH of up to 95% at 30°C without sagging, warping or delaminating (EN 13964).

Fire safety

To BS EN 13501-1, Class A2-s1, d0.

Sound absorption

200 mm-deep system: in accordance with EN ISO 11654, Class A.

Cleaning

Daily dusting and vacuum cleaning, and weekly wet-wiping. Can withstand the use of common disinfecting chemicals. Withstands the use of hydrogen peroxide vapour.

Disinfecting

No change in gloss or colour after undergoing tests using disinfecting chemicals at the Swedish national Research and Testing Institute (SP).

Environmental information

Contains Red List materials

All Ecophon products are free from substances of very high concern (SVHC) and any compound on the list of REACH in the EU.

-

Country of material origin

Sweden, Finland or Poland.

Sweden

Embodied carbon

3.98–4.01 kg CO₂ equiv/m², in conformity with ISO 14025/ EN 15804

Recycled content

44

Similar products from Saint-Gobain Ecophon