Hollow Floor System with Integrated Heating - FLOOR and more® comfort

Verified by manufacturer 2 months ago

Lindner Group Third party certifications:
  • ISO 9001 Quality Management

    Certificate type

  • EPD

    EPD

    Certificate type

Dry hollow floor with integrated heating and cooling.

Jump to:
020 8246 6333 Website

Application

Suitable for offices, hospitals, surgeries, ward rooms, school rooms, restaurants, reading rooms, reception areas, concert halls, lobbies.

Description

The dry hollow floor system FLOOR and more® comfort features tongue and grooved, fibre-reinforced calcium sulphate floor panels, with pre-milled grooves for taking up the heating and cooling lines. The substructure consists of height-adjustable zinc-coated steel pedestals which form the necessary cavity for installations.


Features and benefits:

  • Quick reaction period with heating and cooling.
  • Nearly all covering types are possible including elastic, textile, parquet, ceramic and natural stone.
  • Environmental-friendly due to low flow temperature.

General information

Color

Other

Finish

Other

Material

Calcium sulphate

Guidance for specification option:

Fibre-reinforced.

Steel

Guidance for specification option:

Zinc-coated.

Shape

Square

Length

600 mm

Width

600 mm

Height

40 mm

Warranty description

25 year

Uniclass

Ss_30_20_70_37 Hollow floor systemsPrimary

CAWS

K41/130 Raised access floor

K41/130 Raised access floor

Product range

Lindner Hollow Floor / FLOOR and more® comfort

Specification data - Hollow floor systems

System performance

Carrier panel to BS EN 13501, A1 (non-combustible); to DIN 4102-1, A2 (non-combustible).

System reference

Hollow Floor System with Integrated Heating - FLOOR and More® Comfort.

Standards

To BS EN 13213.

Products

G40 AL x L/B panel (4 kN).

N40 AL x L/B panel (5 kN).

Manufacturer guidance

Pedestals and other components specified separately below.

Structure

Zinc-coated steel pedestals.

Floor surface

Raised access floor panels, fibre-reinforced calcium sulphate.

Load class

To EN 13213, 3.

LoadSafetyFactor

To EN 13213, 2.

NominalCoolingCapacity

To DIN EN 1264 T5, 40 W/m².

Guidance for specification option:

100 mm tube distance.

To DIN EN 1264 T5, 33 W/m².

Guidance for specification option:

150 mm tube distance.

NominalHeatingCapacity

To DIN EN 1264 T2, 76 W/m².

Guidance for specification option:

100 mm tube distance.

To DIN EN 1264 T2, 66 W/m².

Guidance for specification option:

150 mm tube distance.

Panel Thickness

40 mm.

Pedestal height

Guidance for specification option:

40–2000 mm. Insert requirements.

Manufacturer guidance

Pedestal spacing: 600 x 600 mm.

Weight

52 kg/m² (approximately).

Sustainability data

Contains Red List materials

No

Country of material origin

Germany

Country of product manufacture

Germany

Material

Calcium sulphate

Guidance for specification option:

Fibre-reinforced.

Steel

Guidance for specification option:

Zinc-coated.

Recyclability

yes

Recycled content

As defined in clause 7.8 of BS EN ISO 14021

100 %

Third party certifications

Third party certifications

ISO 9001 Quality Management

ISO 9001 Quality Management

ISO 9001 TUV Management Services

EPD

EPD

FLOOR and more EPD

Literature

Hollow Floor - System FLOOR and more

Hollow Floor - System FLOOR and more

Case studies

Covestro, Leverkusen -> Ceilings -> Partition -> Floors

Covestro, Leverkusen -> Ceilings -> Partition -> Floors

Parliament Building Vienna - FLOOR and more® , FLOOR and more® comfort

Parliament Building Vienna - FLOOR and more® , FLOOR and more® comfort

Similar products from Lindner Group

FLOOR and more® - Dry Hollow Floor System

FLOOR and more® - Dry Hollow Floor System

FLOOR and More® G 30 x L / B

FLOOR and More® G 30 x L / B

HYDRO - Dry hollow floor for humid areas

HYDRO - Dry hollow floor for humid areas

Lindner FLOOR and more® G 40 x L/D

Lindner FLOOR and more® G 40 x L/D