Verified by manufacturer 2 days ago
RHTEP7014: 700 x 1400 mm / 68 kg
Highly insulated thermally broken roof hatch with 80 mm insulation, Uw ≤ 0.198 W/m²K for the complete construction. UK supply and support centre. 10-year warranty. Suitable for passive house.
The Highly Insulated roof hatches can be used for flat roofs with a maximum slope of 30°.
Typical applications include:
Alternative roof hatches
For projects with specific requirements or demanding environments, Gorter also offers standard roof hatches, glazed roof hatches, fire-rated roof hatches and bespoke sizes with a single lid or double lid.
The Gorter Highly Insulated Roof Access Hatch - RHTEP can be used as escape hatches, but in most situations, they provide practical and safe access to flat roofs for maintenance work or to a roof terrace. Roof hatches can be installed on flat roofs with a maximum slope of 30°.
Why choose a Gorter roof hatch?
Learn more about the Gorter RHTEP hatch.
Color | White Guidance for specification option: Internal, standard. Black Guidance for specification option: Internal. Grey |
Finish | Powder-coated |
Material | Steel Aluminium |
Shape | Rectangle |
Length | 1400 mm 1500 mm |
Width | 700 mm 1000 mm |
Height | 417 mm Guidance for specification option: Standard (closed) height. Visible height dependent on roof insulation and deck thicknesses. |
Warranty description | Ten year |
Uniclass | |
CAWS | L20/60 Doors L20/630 Hatches |
SKU Code | RHTEP7014 |
Classification data | |
Format | Thermally insulated. |
Door | |
Orientation | Horizontal. |
Position | Flush. |
Material | Manufacturer's standard. Guidance for specification option: Consult manufacturer for details. |
Third-party certification | CE (ETA-18/0287). |
Dimensions | 700 x 1400 mm. Guidance for specification option: The opening size of the roof hatch will match the structural opening size of the roof. Hinge side = long side. Manufacturer guidanceWidth x length. |
Weight | 68 kg. |
Colour/ Finish | Powder-coated; external: RAL 7047; internal: RAL 9010 (white). |
Locking | Stainless steel Euro cylinder lock, inside and outside operation. |
Insulation | Roof hatch to EN ISO 10077-2, Uw ≤0.20 W/m²K. |
Impact resistance | Roof hatch: Impact hard body to EN 356, Class P5A. Impact soft body to EN 13049, Class 5. |
Load resistance | Roof hatch: resistance to permanent loads to Eurocode EN 1993-1-1, 1050 kg/m². Manufacturer guidanceResistance to permanent loads. |
Sound reduction | Roof hatch to EN ISO 140-3, ≥26 dB. |
Air permeability | Roof hatch to EN 12207, Class 3. |
Watertightness | Roof hatch to EN 12208, Class E 650. |
Wind load resistance | Roof hatch to EN 12210, Class E 3000. |
Snow load | Roof hatch to EN 1991-1-3, 3.97 kN/m². |
Integral accessories | Diagonal Gorter handrail. Counterbalancing system for assisted opening and controlled closing. Spring mechanism. Guidance for specification option: Handrail is on inside lid to safely enter and leave roof hatch. |
Contains Red List materials | No |
Country of product manufacture | Europe |
Manufacturing plant location | |
Material | Steel Aluminium |
Expected Life | 25 year |
| Platform | Compatible | Version |
|---|---|---|
| - | 1 | |
| - | 1 |
Flat Roof Access Hatch - RHT Standard -thermally broken construction
Gorter Complete Roof Access - RHTS with Integrated Scissor Stair - thermally broken construction
Gorter Fire Rated Roof Access Hatch - RHTEI - 120 minutes - thermally broken curb and a cover
Gorter Flat Roof Access Hatch - RHT Special sizes – Double lid hatch and hoisting hatch - thermally broken construction
Gorter Flat Roof Access Hatch - RHT Special sizes, Single Lid - thermally broken construction
Gorter Flat Roof Access Hatch with Fixed Stairs - RHT with GS50 or GS55 - thermally broken construction
Gorter Glazed Roof Hatch with HR+++ glass - RHTG - thermally broken curb and a cover
Gorter Roof Access Hatch RHT with Ladder - thermally broken construction - ladder access hatch
Gorter Roof Access Hatch RHT with Scissor Stair - Retractable Ladder - thermally broken construction