NBS Source
I'm a manufacturer
Compare variants

GuideLED DX CG-S - Central Battery Adaptive Exit Sign

Verified by manufacturer 6 months ago

GuideLed DX 10011 CG-S - 40071354646

Eaton Electric Variant:

Adaptive escape sign luminaire that enables real-time adjustment of exit routes according to the nature and location of a hazard.

Jump to:
01753 608 700 Website

Application

Suitable for use in commercial applications.

Description

GuideLED DX CG-S is the next generation of central battery emergency exit signs. Able to adapt its status depending on CCTV, fire detection or other inputs, it ensures the safest possible evacuation route is communicated to building users, achieved through the ability to display a red "X" to signify a closed or blocked area. The exit sign can be installed on walls or ceilings with suspended and recessed mounting options and viewing distance options of 20 or 30 metres.


Features and benefits:

  • Escape sign luminaire with LED Lightguide technology.
  • Displays a red ‘X’ to signify an area as closed or blocked.
  • Activated by a switching input on the supply module.
  • GuideLed DX: activation via a switching input on the supply module e.g. smoke detector or panic switch via potential free contact.
  • Without power supply: still visible pictogram.
  • Increased visibility in bright surroundings possible via additional selectable function modes, e.g. flashing red ‘X’.
  • Very good perceptibility on account of high luminance of the white contrasting colour > 500 cd/m² in keeping with standard ISO 3864-1 and high uniformity Lmin/Lmax >0.8.
  • Reduced battery costs on account of especially low power consumption.
  • Minimum service requirement due to high service life of the LEDs (50 000 hours).
  • Installation of the LED pictogram without tools on the mounting set.
  • Fully conforms with German and European standards including EN 60598-1, DIN EN 60598-2-22, DIN 4844-1 and DIN EN 1838.

General information

Color

Grey

Material

Polycarbonate

Polymethyl methacrylate (PMMA)

Shape

Rectangle

Length

44 mm

80 mm

92 mm

Manufacturer guidance

Depth.

Width

226 mm

326 mm

Height

134 mm

176 mm

184 mm

217 mm

Uniclass

Pr_70_70_48_25 Emergency luminairesPrimary
Pr_70_70_48_23 Dedicated slave emergency luminaires

CAWS

V90/550 Centrally supplied emergency luminaires

V90/510 General-purpose luminaires

V90/510 General purpose luminaires

Specification data - Emergency luminaires

Standards

To BS EN IEC 60598-1 and BS EN 60598-2-22.

Luminaire description

Adaptive exit sign luminaire with 20 m viewing distance.

Classification

-

Ingress protection (minimum)

IP20.

Circumstances of use

Normal.

Type

Z.

Rated maximum ambient temperature

40℃.

Guidance for specification option:

Permissible ambient temperature: -20°C to +40°C.

Controlgear position

Integral within luminaire.

Supply circuit conductor connections

Guidance for specification option:

Connection terminal:

  • Mains 3 x 2 x 2.5 mm².
  • Switch input 2 x 2 x 1.5 mm².

Nominal voltage

220–240 V a.c (50/60 Hz).
176–275 V d.c.

Luminaire power factor

Not applicable.

LED luminaires

-

Initial LED luminaire efficacy (minimum)

Guidance for specification option:

Light source: LED batten.

Wattage

2.2 W.

Guidance for specification option:

Power consumption mains operation, effective power: 4.7 VA.

Manufacturer guidance

Power consumption mains operation, apparent power. / effective power) 

Useful life

Luminous flux at end of rated operating time, 100%.

Graphical symbol format

Not required.

To BS EN ISO 7010, LED cover pictogram arrow left (PL).

Guidance for specification option:

40071355550.

To BS EN ISO 7010, LED cover pictogram arrow right (PR).

Guidance for specification option:

40071355551.

To BS EN ISO 7010, LED cover pictogram arrow down (PU).

Guidance for specification option:

40071355552.

To BS EN ISO 7010, LED cover pictogram arrow up (PO).

Guidance for specification option:

40071355553.

Accessories

Not required.

Red 'X'.

Inrush current

1.5 A.

Current

7 mA.

Manufacturer guidance

Current consumption - battery operation (220 V). 

Housing

Polycarbonate (PC) and polymethyl methacrylate (PMMA).

Housing colour

Light grey (RAL 7035).

Mounting

Wall-mounted.

Weight

0.65 kg.

Literature

GuideLed DX 11011 CG-S

GuideLed DX 11011 CG-S

GuideLed DX 11021, 11022, 11023, 11024 CG-S

GuideLed DX 11021, 11022, 11023, 11024 CG-S

GuideLed DX 10011 CG-S

GuideLed DX 10011 CG-S

GuideLed DX 10021, 10022, 10023, 10024 CG-S

GuideLed DX 10021, 10022, 10023, 10024 CG-S

Similar products from Eaton Electric

46011 LED (60 m) CG-S - Safety and Exit Sign Luminaires

46011 LED (60 m) CG-S - Safety and Exit Sign Luminaires

46811 LED (60 m) CG-Line - Safety and Exit Sign Luminaires

46811 LED (60 m) CG-Line - Safety and Exit Sign Luminaires

Atlantic LED CG-Line - Self-Contained Safety and Exit Sign

Atlantic LED CG-Line - Self-Contained Safety and Exit Sign

Atlantic LED II CG-S - Central Battery Bulkhead

Atlantic LED II CG-S - Central Battery Bulkhead

Crystal Way CG-Line  - Self-Contained Exit Sign

Crystal Way CG-Line - Self-Contained Exit Sign

Crystal Way CG-S - Exit Sign Panel Luminaire

Crystal Way CG-S - Exit Sign Panel Luminaire

Exit Cube CG-Line - Self-Contained Exit Sign Panel

Exit Cube CG-Line - Self-Contained Exit Sign Panel

Exit Cube CG-S - Central Battery Exit Sign

Exit Cube CG-S - Central Battery Exit Sign

i-P65+ - Central Battery IP65 Safety Luminaire - High Power Bulkhead

i-P65+ - Central Battery IP65 Safety Luminaire - High Power Bulkhead

i-P65+ - Self-Contained Safety Luminaire - High Power Bulkhead

i-P65+ - Self-Contained Safety Luminaire - High Power Bulkhead