RHT1015: 1000 x 1500 mm / 84 kg
Thermally broken roof hatch with fixed stairs with 80 mm insulation, Uw ≤0.276 W/m²K for complete construction, safety rail, powder-coated. UK supply and support centre. 10-year warranty.
The Gorter RHT standard roof hatch with fixed stairs is suitable for installation on flat roofs with a maximum slope of 30° and can be used in a wide range of buildings, including offices, factories, apartment buildings, villas, shopping malls, hotels and public-sector facilities. It provides a safe and compliant solution for roof access and emergency escape, enabling routine maintenance, inspections, servicing of rooftop installations, roof terrace access and emergency egress.
Typical applications include:
WIth fixed stairs
The roof hatch can also be supplied as a complete TÜV Nord-certified roof access solution combined with fixed stairs GS55.
Alternative roof hatches
The RHT roof hatch is also available in bespoke sizes with a single lid or double lid. For projects with specific requirements or demanding environments, Gorter also offers Standard roof hatch, glazed roof hatches, roof hatches with extreme insulation values, and fire-rated roof hatches.
The Gorter RHT with fixed stairs roof hatch has been installed in a wide variety of projects worldwide. Click here for more reference projects.
The RHT roof hatches with fixed stairs feature a strong and patented construction. Due to several modifications, the roof hatch is even more resistant against unexpected extreme loads, both during construction and in general use.
Proven insulation performance of the complete roof hatch
With the RHT roof hatch, the insulation value is calculated for the entire construction (Uw), not just the insulation material. The proven insulation performance of the complete hatch is Uw ≤ 0.276 W/(m²·K).
Why choose a Gorter roof hatch?
Fixed stairs
Gorter Fixed stair, type GS50
Gorter Fixed stair, type GS55
Learn more about the Gorter standard roof hatch with fixed stairs.
Color | Grey Guidance for specification option: External. White Guidance for specification option: Internal, standard. Black Guidance for specification option: Internal. |
Finish | Powder-coated |
Material | Steel Aluminium |
Shape | Rectangle |
Length | 1000 mm 2000 mm 2500 mm 3000 mm |
Width | 1000 mm |
Height | 376 mm Guidance for specification option: Standard (closed) height. |
Warranty description | Ten year |
Uniclass | |
CAWS | L20/60 Doors L20/630 Hatches |
SKU Code | RHT1015, RHT1020, RHT1025, RHT1030, GS50, GS55 |
Classification data | |
Format | External. |
Door | |
Orientation | Horizontal. |
Position | Flush. |
Material | Manufacturer's standard. Guidance for specification option: Consult manufacturer for more details. |
Operation | |
Mode | Automatic. Guidance for specification option: Two electric motors. |
Control | Manufacturer guidanceConsult manufacturer for details and insert requirements. |
Third-party certification | CE (ETA-15/0338). Aboma certificate. |
Dimensions | 1000 x 1500 mm. Guidance for specification option: The opening size of the roof hatch will match the structural opening size of the roof. Hinge side = long side. |
Floor-to-ceiling height | Manufacturer guidanceConsult manufacturer for options/ details and insert height requirements. See ladder details bellow for maximum height guidance. |
Weight | 84 kg. |
Applied finish | Roof hatch: Powder-coated. Ladder: Anodized. |
Colour | Roof hatch: external: RAL 7047; internal: RAL 9010. Roof hatch: external: RAL 7047; internal: RAL 9004. |
Ladder | Aluminium anodized fixed stair type GS50. Guidance for specification option:
|
Locking | Stainless steel Euro cylinder lock, inside and outside operation. |
Glazing | Glazed lid, insulated with HR+++ glass. |
Insulation | Roof hatch to EN ISO 10077-2, Uw ≤0.276 W/m²K. Insulating value HR+++ glass: U ≤0.500 W/m²K. |
Impact resistance | Roof hatch: Impact hard body to EN 356, Class P5A. Impact soft body to EN 13049, Class 5. |
Load resistance | Roof hatch: resistance to permanent loads to Eurocode EN 1993-1-1, 1050 kg/m². Manufacturer guidanceResistance to permanent loads. |
Sound reduction | Roof hatch to EN ISO 140-3, 26 dB. |
Air permeability | Roof hatch to EN 12207, Class 3. |
Watertightness | Roof hatch to EN 12208, Class E 650. |
Wind load resistance | Roof hatch to EN 12210, Class E 3000. |
Snow load | To EN 1991-1-3, 3.97 kN/m². |
Integral accessories | Diagonal Gorter yellow handrail. Counterbalancing system for assisted opening and controlled closing. Fixing brackets. Guidance for specification option:
|
Contains Red List materials | No |
Country of product manufacture | Netherlands |
Manufacturing plant location | |
Material | Steel Aluminium |
Expected Life | 25 year |
| Platform | Compatible | Version |
|---|---|---|
| - | 1 | |
| - | 1 |
Gorter RHT Standard Roof Hatch - Brochure
Gorter Fixed stairs GS50 - Floor heights from 2500 - 3000 – Technical 2D Drawing
Gorter Fixed stairs GS55 - Floor heights from 3000 - 3370 – Technical 2D Drawing
Gorter RHT1015 Roof Hatch – Technical 2D Drawing
Gorter RHT1020 Roof Hatch – Technical 2D Drawing
Gorter RHT1025 Roof Hatch – Technical 2D Drawing
Gorter RHT1030 Roof Hatch – Technical 2D Drawing
Flat Roof Access Hatch - RHT Standard -thermally broken construction
Gorter Complete Roof Access - RHTS with Integrated Scissor Stair - thermally broken construction
Gorter Fire Rated Roof Access Hatch - RHTEI - 120 minutes - thermally broken curb and a cover
Gorter Flat Roof Access Hatch - RHT Special sizes – Double lid hatch and hoisting hatch - thermally broken construction
Gorter Flat Roof Access Hatch - RHT Special sizes, Single Lid - thermally broken construction
Gorter Glazed Roof Hatch with HR+++ glass - RHTG - thermally broken curb and a cover
Gorter Highly Insulated Roof Access Hatch - RHTEP - thermally broken curb and a cover
Gorter Roof Access Hatch RHT with Ladder - thermally broken construction - ladder access hatch
Gorter Roof Access Hatch RHT with Scissor Stair - Retractable Ladder - thermally broken construction