Glidevale Protect Venta-Line TLE In-line® Tile Ventilator - Roof Tile Vent

Verified by manufacturer 2 days ago

BPD Building Product Design Ltd

Flat Interlocking Ventilator with a 10,000 mm² ventilation area, in compliance with BS 5250. For use with thin leading edge (TLE) roof tiles.

Jump to:
+44 (0)161 905 5700 Website

Application

Venta-Line TLE has been fit tested and is compatible with many leading thin leading edge roof tiles, including Russell Galloway, Condron Senior TLE, Marley Edgemere, Northstone Causeway, and Redland Richmond 10. The vent is not designed to be compatible with the Sandtoft Danum TLE or Dual Danum TLE roof tiles.

Description

The Venta-Line TLE is a flat interlocking, low profile tile ventilator designed to deliver airflow to the roof space. With a flexible application either as ventilation for condensation control, a terminal for soil pipe ventilation or a mechanical extract, the Venta-Line TLE is specifically engineered to integrate seamlessly in line with the adjacent roof tiles. Suited for use with the majority of thin leading edge, large format concrete tiles, the vent is designed to replace a single roof tile whilst maintaining a consistent and aesthetic appearance across the roof line.

The TLE vent provides continuous airflow, with a minimum geometric free ventilation area of 10,000 mm², helping to meet the requirements of BS 5250. It can be installed at both high and low level and also in areas where the roof construction does not allow for eaves or ridge ventilation. By providing ventilation across the roof, the Venta-Line TLE helps to deliver a healthy and well-ventilated roof space, with built in weather protection ensuring any rainwater is safely channelled away, helping to strengthen the roof’s long-term durability.

Features and benefits:

  • Suitable for roofs with a pitch of 20° and above.
  • An interlocking slimline design tested with commonly used thin edge roof tiles.
  • Unobtrusive profile with an integrated flush grille ensures the vent is virtually unseen from the ground.
  • The integrated lower tray is engineered to channel rainwater away from the throat of the vent and back down onto the roof tiles, ensuring no ponding of water.
  • Concealed baffles catch any wind driven rain or snow that might penetrate the grille and return it via positive drainage channels to the roof slope.
  • Integral 4 mm spaced grille to prevent the ingress of nesting insects.
  • Manufactured using UV stabilised uPVC with embedded silica sand to generate a surface that weathers in line with the rest of the roof covering.

General information

Color

Grey

Brown

Red

Guidance for specification option:

Red, Terracotta or Red Streak.

Black

Guidance for specification option:

Black or Blue/Black.

Finish

Sanded

Manufacturer guidance

Tile moulding manufactured using UV stabilised uPVC with embedded silica sand on the surface to generate a realistic finish.

Material

PVC-U

Shape

Rectangle

Length

420 mm

Width

323 mm

Height

20 mm

Uniclass

Pr_30_59_29_73 Roof slope ventilator tilesPrimary

CAWS

H65/86 Ventilator tiles

H65/840 Ventilator tiles

H60/840 Ventilator tiles

H60/86 Ventilator tiles

SKU Code

GV30017895

Specification data - Roof slope ventilator tiles

Classification data

Purpose

Roof void ventilator.

Ventilation opening

10 000 mm².

Colour

Grey.
Terracotta.
Brown.
Red.
Red streak.
Black.
Blue black.

Accessories

Not required.
Flexible connecting pipe.
Soil universal adaptor (SUA).

Roof pitch

>20°.

Manufacturer guidance

Minimum roof pitch.

Head-lap

75 mm/ 100 mm.

Manufacturer guidance

Head-lap depends on roof pitch and should match surrounding tiles

Dimensions

420 x 323 x 20 mm.

Manufacturer guidance

Length x overall width x thickness.

Cover Width

295 mm.

Weight

1.07 kg.

Air flow

54 m³/hr (15 litres/second) (9 Pa).
108 m³/hr (30 litres/second) (33.2 Pa).
216m³/hr (60 litres/second) (128.7 Pa).

Manufacturer guidance

Airflow resistance when used as soil vent pipe (SVP)/extract terminal.

Sustainability data

Country of product manufacture

United Kingdom

Material

PVC-U

Recycled content

As defined in clause 7.8 of BS EN ISO 14021

-

Manufacturer guidance

Base plate is manufactured in polypropylene with up to 100% recycled content.

BIM objects

Platform Compatible Version
Revit
-

1

IFC
-

1

Literature

Glidevale Protect Venta-Line TLE In-line® Tile Ventilator

Glidevale Protect Venta-Line TLE In-line® Tile Ventilator

Glidevale Protect - Fixing Instructions - Venta-Line TLE In-line® Tile Ventilator

Glidevale Protect - Fixing Instructions - Venta-Line TLE In-line® Tile Ventilator

BS 5250:2021 Management of moisture in buildings

BS 5250:2021 Management of moisture in buildings

Similar products from BPD Building Product Design Ltd

Glidevale Protect G5 Plain Tile Ventilator

Glidevale Protect G5 Plain Tile Ventilator

Glidevale Protect G5 Slate Ventilator

Glidevale Protect G5 Slate Ventilator

Glidevale Protect GV11 Slate Ventilator - Slate Vent

Glidevale Protect GV11 Slate Ventilator - Slate Vent

Glidevale Protect In-line® Plain Tile Ventilator - Roof Tile Vent

Glidevale Protect In-line® Plain Tile Ventilator - Roof Tile Vent

Glidevale Protect Universal In-line® Flat Interlocking Tile Ventilator - Roof Tile Vent

Glidevale Protect Universal In-line® Flat Interlocking Tile Ventilator - Roof Tile Vent

Glidevale Protect Universal In-line® Interlocking Plain Tile Ventilator - Roof Tile Vent

Glidevale Protect Universal In-line® Interlocking Plain Tile Ventilator - Roof Tile Vent

Glidevale Protect Universal In-line® Slate Ventilator - Roof Slate Vent

Glidevale Protect Universal In-line® Slate Ventilator - Roof Slate Vent