Verified by manufacturer 6 months ago
EPD
Certificate type
EPD
Certificate type
BBA Agrément Certificate
Certificate type
BBA Agrément Certificate
Certificate type
BBA Agrément Certificate
Certificate type
BBA Agrément Certificate
Certificate type
Fully integrated, solar powered, maintenance free, white polyurethane, centre pivot roof window for roof pitches between 15–90°.
Designed to be used on roofs with pitches from 15–90°. Ideal for out-of-reach areas.
Features and benefits:
Glazing:
- Code 6830:
- Code 6630:
- Code 7030:
Energy efficiency installation collars:
Flashing:
Flashings are available in materials and finishes to match roof window cladding.
Color | White Grey |
Finish | Painted Guidance for specification option: Internal frame and sash has a white lacquer finish on moulded polyurethane around a timber core. External cladding is available in grey aluminium; colour reference NCS S-7500-N - Code 0, untreated copper – Code 1, titanium zinc – Code 3 and painted aluminium – Code 8, colour |
Material | Timber Guidance for specification option: Timber core Polyurethane Guidance for specification option: Polyurethane coated frames Aluminium Guidance for specification option: Aluminium cladding Glass |
Shape | Rectangle |
Width | 780 mm 942 mm 1140 mm 1340 mm 660 mm |
Height | 978 mm 1178 mm 1398 mm 1600 mm 780 mm |
Warranty description | Ten year Guidance for specification option: For window and pane |
Uniclass | |
CAWS | L10/480 Roof windows |
SKU Code | GGU **** 00**30A |
Product range |
Classification data | |
Product performance | |
Whole window U-value | 0.88–1.3 W/m²K. Guidance for specification option: Depending on product option. |
Glazing or infill | |
Composition | Argon filled cavity or Krypton filled cavity depending on product option. |
Hardware | Flashings are available in materials and finishes to match roof window cladding. |
Operation | |
Type | Solar powered. Guidance for specification option: photovoltaic cell on the external window frame charges the battery which in turn powers the motor for operation; PV cell requires direct exposure to sunligh |
Accessories | Not required. VELUX ACTIVE with NETATMO. Guidance for specification option: Code KIX 300 - Smart sensor based operation and smartphone control. |
Internal frame and sash | White polyurethane lacquer. Guidance for specification option: Code 0 |
External cladding | Grey aluminium; colour reference NCS S-7500-N. Guidance for specification option: Code 0 Untreated copper. Guidance for specification option: Code 1 Titanium zinc. Guidance for specification option: Code 3 Painted aluminium. Guidance for specification option: Code 8, colour |
Roof pitch | Guidance for specification option: Insert requirements. |
Window code | GGU CK02. Guidance for specification option: Standard size 550 mm wide x 778 mm high, effective daylight area 0.22 m². GGU CK04. Guidance for specification option: Standard size 550 mm wide x 978 mm high, effective daylight area 0.29 m². GGU CK06. Guidance for specification option: Standard size 550 mm wide x 1178 mm high, effective daylight area 0.37 m². GGU FK06. Guidance for specification option: Standard size 660 mm wide x 1178 mm high, effective daylight area 0.47 m². GGU MK04. Guidance for specification option: Standard size 780 mm wide x 978 mm high, effective daylight area 0.47 m². GGU MK06. Guidance for specification option: Standard size 780 mm wide x 1178 mm high, effective daylight area 0.59 m². GGU MK08. Guidance for specification option: Standard size 780 mm wide x 1398 mm high, effective daylight area 0.72 m². GGU PK08. Guidance for specification option: Standard size 942 mm wide x 1398 mm high, effective daylight area 0.92 m². GGU PK10. Guidance for specification option: Standard size 942 mm wide x 1600 mm high, effective daylight area 1.07 m². GGU SK06. Guidance for specification option: Standard size 1140 mm wide x 1178 mm high, effective daylight area 0.95 m². GGU UK04. Guidance for specification option: Standard size 1340 mm wide x 978 mm high, effective daylight area 0.91 m². GGU UK08. Guidance for specification option: Standard size 1340 mm wide x 1398 mm high, effective daylight area 1.40 m². GGU FK04. Guidance for specification option: Non-standard size 660 mm wide x 978 mm high, effective daylight area 0.38 m². GGU FK08. Guidance for specification option: Non-standard size 660 mm wide x 1398 mm high, effective daylight area 0.58 m². GGU MK10. Guidance for specification option: Non-standard size 780 mm wide x 1600 mm high, effective daylight area 0.85 m². GGU PK06. Guidance for specification option: Non-standard size 942 mm wide x 1178 mm high, effective daylight area 0.75 m². GGU SK08. Guidance for specification option: Non-standard size 1140 mm wide x 1398 mm high, effective daylight area 1.16 m². |
Glazing | 6830. Guidance for specification option: 6.8 mm laminated inner pane with low-e coating; 12 mm Argon filled cavity; 3 mm heat strengthened mid pane with low-e coating; 12 mm Argon filled cavity; 4 mm toughened outer pane with easy to clean and low-e coatings. 6630. Guidance for specification option: 6.8 mm laminated inner pane with low-e coating; 12 mm Krypton filled cavity; 3 mm heat strengthened mid pane with low-e coating; 12 mm Krypton filled cavity; 4 mm toughened outer pane with easy to clean and anti-dew coatings. 7030. Guidance for specification option: 6.8 mm laminated inner pane with low-e coating; 15 mm Argon filled cavity; 4 mm toughened outer pane. |
Type | Not required. Blackout blind – code DSL. External awning blind – code MSL. External shutter – code SSL. Light dimming energy blind – code FSC. Pleated blind – code FSL. |
Colour | Not applicable. As schedule. Guidance for specification option: Refer to VELUX Blinds and Shutters brochure for available colours and patterns. |
Energy efficiency installation collars | Insulation Collar – Code BDX 2000. Guidance for specification option: Not compatible with EDN and EDJ flashings. Includes BFX. Insulation Collar – Code BDX 2000F. Guidance for specification option: Compatible with EDN and EDJ flashings only. Includes BFX. Underfelt Collar – Code BFX 1000. Vapour Barrier Collar – Code BBX 0000. |
Flashing | EDL. Guidance for specification option: For standard installation in slate up to 8 mm thick; roof pitch 15–90°. EDN. Guidance for specification option: For recessed installation in slate up to 8 mm thick; roof pitch 20–90°. EDW. Guidance for specification option: For standard installation in tiles up to 120 mm in profile; roof pitch 15–90°. Also for interlocking slate, thatch and profile sheeting. EDJ. Guidance for specification option: For recessed installation in tile up to 90 mm in profile; roof pitch 20–90°. EDP. Guidance for specification option: For standard installation in plain tiles up to 14 mm thick; roof pitch 25–90°. ZWC. Guidance for specification option: For standard installation where an on-site flashing is required; roof pitch 15-90°. |
Contains Red List materials | Yes |
Country of material origin | Europe |
Country of product manufacture | Europe |
Manufacturing plant location | |
Material | Timber Guidance for specification option: Timber core Polyurethane Guidance for specification option: Polyurethane coated frames Aluminium Guidance for specification option: Aluminium cladding Glass |
Carbon dioxide equivalent | |
Carbon dioxide equivalent, as defined in BS EN 15804 Certified | |
Stage Normalised unit (kg CO₂ eq/kg) Declared unit (kg CO₂ eq/unit) Stage:A1–A3 ('Production stage') Normalised unit : Declared unit 2.7 : | |
Recyclability | yes |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 12 % |
Expected Life | 30 year |