NBS Source
List your products
Firestrip® 30

Firestrip® 30

Third party certifications:
  • Certifire Certificate

    Certifire Certificate

    Certificate type

  • QA Certificate

    QA Certificate

    Certificate type

Hodgson Sealants

An intumescent butyl strip sealant which can provide 30 minutes resistance to the passage of fire and smoke when used to glaze a wide variety of glass types into internal timber doors and softwood or hardwood timber screens.

Jump to:
+44 (0)1482 868321 www.hodgsonsealants.com
Application

  • The product is used for glazing non-insulating and insulating glass into timber fire doors and softwood or hardwood timber screens with hardwood beads using Hodgson FG2 Glazing System.
  • Consult literature for details of which glass can be glazed using Firestrip® 30.
  • Dependent on the use of suitable fire resistant glass and suitable frame design. Consult the manufacturer for further details.

Description

An intumescent strip sealant which can provide 30 minutes resistance to the passage of fire and smoke when used to glaze a wide variety of glass types into internal doors and softwood or hardwood timber screens.

Features and benefits:

  • Fully tested to provide 30 minutes resistance to the passage of fire and smoke in timber doors and screens.
  • Quick, clean and easy to apply.
  • British Woodworking Federation (BWF) Certifire Scheme Certificate No. CF297 for use in timber screens and doors for periods of 30 minutes fire resistance.
  • Good high tack surface provides a high level of adhesion.
  • Tested with a wide variety of non-insulating and insulating glass types.
  • Can be over-coated with paints and decorative wood stains.
  • Quick, clean and easy to apply.
  • Cost-effective compared to other rigid/ semi-rigid fire resistant materials.
  • Non-toxic.

Standards/ Approvals:

  • BS 8000-7.
  • FIRAS register of specialist fire protection materials – Manufacturers and Suppliers.
  • Glass and Glazing Federation Glazing Manual Section 2.8 Fire Resistant Glazing, 13. Table of Tested Products and Materials. 9.1.2 Glazing Materials – Strips.

Applications:

  • The product is used for glazing non-insulating and insulating glass into timber fire doors and softwood or hardwood timber screens with hardwood beads using Hodgson FG2 Glazing System.
  • Consult literature for details of which glass can be glazed using Firestrip® 30.
  • Dependent on the use of suitable fire resistant glass and suitable frame design. Consult the manufacturer for further details.

General information

Size

12 mm x 15 m (w x l)

15 mm x 30 m (w x l)

Uniclass 2015

Pr_25_80_81_29 Flexible intumescent gap sealsPrimary

CAWS

P12/330 Flexible intumescent gap sealer

Specification data - Flexible intumescent gap seals

Product Reference

Firestrip® 30

Certifire CF 297 certified

Size

12 mm x 15 m (w x l)

15 mm x 30 m (w x l)

Fire performance

Fully tested to provide 30 minutes resistance to the passage of fire and smoke

Colour

Mahogany

Off-white

Thickness

1.5 mm (30 m variant), 3 mm (15 m variant)

Standard product features

Technical characteristics:

  • Adhesion: Excellent (to glass and timber).
  • Compression to seal: Positive compression.
  • Density: 1.2 g/cm³.
  • Force to compress by 20%: 1.4 kg/cm².
  • Movement accommodation: ±10%.
  • Resistance to mould: High.
  • Shrinkage: <1%.
  • Slump: Nil.
  • Staining: Nil.
  • Tack: Very good.
  • Tensile strength: 1.3 kg/cm².
  • Ultraviolet (UV) resistance: Excellent.
  • Application temperature range: 5–30°C.
  • Service temperature range: 5–40°C.

Third party certifications
  • Certificate: CF 297 : EN 1364-1: 1999 WFRC 135349, WFRC 142630 BWF - Certifire Fire Door and Doorset Scheme
  • Warrington Fire Research Centre (WFRC): Certificate: WFRC 70068 and WFRC C82960 : BS 476-22
  • Chilt: Certificate: Chilt/ RF02065, Chilt/ RF02064 and Chilt/ RF02063