Verified by manufacturer 4 months ago
Single glazed fire rated timber framed partition system.
All sectors: Commercial, Education, Healthcare, MOD, Airport & Rail, Industrial, Hospitality, Residential, & Public. Consult manufacturer for details.
Single glazed fire rated timber framed partition system. Part of a range of single or double glazed partition systems with fire insulation of Ei30 or Ei60 (other formats specified separately).
Please note that acoustic, fire rated and structural certification and support for Planet products and systems is available on a project-specific basis. Please contact the specification team directly for further information.
Color | Other Any RAL code (wet spray), natural timber or primed. |
Finish | Natural Primed |
Material | Timber Hardwood timber ≥640 kg/m³. Glass |
ShapeTo suit project requirements; consult manufacturer for further details. | - |
Warranty descriptionDealt with on a project specific basis as part of the O&M process; consult manufacturer for details. | - |
Uniclass | |
CAWS | K30/130 Relocatable partition system K30/10 Relocatable partition system |
Product range |
Third party accreditation | ISO 9001-UKAS (Quality); ISO 14001-UKAS (Environmental); Constructionline-Gold; Acclaim (SIPP); Achilles (Building confidence, SIPP); EPD - material accreditation & compliance; FIS Member; Considerate Construction; FORS Bronze; Build Profile.EPD - material accreditation & compliance: Consult manufacturer for details (glass, PPC, aluminium, timber, ironmongery, waste, adhesive and more). |
Unit size | - |
Thickness | 95 mm. |
Partition height (nominal)3000 mm maximum; consult with manufacturer to ensure compliance with certification. | - |
Width (nominal)Restricted minimum and maximum widths - consult with manufacturer to ensure compliance with certification. | - |
Deflection allowance (maximum) | - |
FloorConsult with manufacturer for system weight. | - |
Verticals | 50 mm deep x 95 mm wide. |
Panel partition type | Frameless glass - centre glazed. |
Framing, junctions, cornersCorners: Not applicable. | 50 mm deep x 95 mm wide. |
Joint treatment | - |
Type | Butt jointed glazing; single glazed.Consult with manufacturer to ensure compliance with test/assessment data. |
Finish and colour | Coloured silicone.Consult manufacturer and insert requirements. |
Glazed panels | - |
Type | Single centre glazed: 17 mm annealed multi-laminate fire glass.Consult with manufacturer to ensure compliance with test/assessment data. |
Door arrangement | - |
Type | 44 mm timber, single leaf door, single action.44 mm timber, unequal leaf doors, single action.44 mm timber, double leaf doors, single action. |
Door frames | Stand alone doorset 65 mm deep x 95 mm wide.With side or fanlight glazing 115 mm deep x 95 mm wide. |
Door leafs | - |
Type | Halspan 44 mm Prima Core(IFCA/06166).Halspan 44 mm Optima Core(PAR/1034/01A:C01).Falcon 44 mm Streboard Core (IFCA/08037). |
Vision panels | Required.Restricted to sizes within fire certification - consult with manufacturer and insert requirements. Not required. |
Ceiling | - |
TypeFire rated construction - consult with manufacturer for interface detail and insert requirements. | - |
Method of supportConsult manufacturer for support detail and insert requirements. | - |
Perimeters, skirtings, sills | 50 mm deep x 95 mm wide. |
HardwareConsult manufacturer and insert requirements. | - |
Seals | Intumescent silicone; Fire rated Solar PVC-U translucent ‘H’ joint. |
Cable management and outletsConsult manufacturer and insert requirements. | - |
Other featuresConsult manufacturer and insert requirements. | - |
ManifestationTo architects choice and in accordance with the requirements of Approved Document K. | Allowance of 2 nr rows 50 mm dots or square (minimum) Opal Frost. Insert requirements. Artwork and custom manifestation to client design. Insert requirements. |
StrengthGradeConsult with the manufacturer to ensure the system complies with current regulations BS 5234:1992 non load-bearing screens not protecting a change in adjacent floor level of >380 mm. For glass load resistance criteria;
Building regulations Part N (BS 6262 & BS EN 12600) + InsStucEng publication “structural use of glass in buildings” insert as required:
BS 6180:2011 barriers in and about buildings for Atria or protected change in adjacent floor level of >380 mm. Horizontal uniformly distributed line load 1100 mm above FFL (glass deflection limited to L/65 or 25 mm, whichever is less relative to glass fixings). Structural glass based on line-load and attendant UDL + point load, insert as required:
| - |
Acoustic performance | 39 dB Rw. |
Fire insulation | Ei30 (30/30 Integrity and Insulation) |
Partition | Frameless glass - single centre glazed. |
Fasteners | To manufacturer's specification, type, length and frequency to suit substrates. |
Joint treatment | Butt jointed glazing. |
Samples requiredConsult with manufacturer. | - |
Finish/ Colour | Natural timber finish. Factory primed. Wet spray to match RAL colour. Insert requirements. |
Contains Red List materials | No No substance on the “Candidate List of Substances of Very High Concern for authorisation” derived under REACH is present either above the limits for registration with the European Chemicals Agency or in excess of 1 weight–% of the product. |
Country of material origin | United Kingdom |
Country of product manufacture | United Kingdom |
Recyclability | 100% Timber and glass. |
Recycled content | 28 % 17–28% for glass. |
FireClear100 Double Glazed Partition System
FireClear20 Single Glazed Partition System
FireClear54 Double Glazed Partition System
FireEco Ei30 Double Glazed Partition System
FireEco Ei60 Double Glazed Partition System
FireEco Ei60 Single Glazed Partition System
FirePro E120 Single Glazed Partition System And Ei 60 Doorset
FirePro E30 Double Glazed Partition System And Doorset
FirePro E30 Single Glazed Partition System and Doorset
FirePro E60 Double Glazed Partition System and Doorset