Verified by manufacturer 9 months ago
93 mm wall thickness.
Independent lining system.
Independent dry linings.
Metal stud lining system based on fermacell® gypsum fibreboard linings. Homogeneous dry lining board made from recycled gypsum, recycled cellulose fibres from post consumer waste paper and recycled water.
Features and benefits:
Color | Grey Manufacturer guidanceBoard colour. |
Material | Gypsum Guidance for specification option: fermacell® Gypsum-Fibreboard consists of a homogeneous mixture of water, gypsum and cellulose fibre compressed at high pressure. |
Shape | Rectangle |
Length | 2400 mm 2700 mm 3000 mm |
Width | 1200 mm |
Uniclass | |
CAWS | K10/155 Wall lining system (metal studs) K10/30 Metal stud |
System performance | Fire integrity, EI30. |
Insulation | Glass wool insulation.Guidance for specification option: Minimum of 40 mm. |
Linings | |
Inner layers | Not applicable.18 mm fermacell® gypsum-fibreboard. |
Fasteners | fermacell® screws.Guidance for specification option: 30 mm fermacell® screws at 250 mm centres. |
Joint treatment | fermacell® Jointstik 1 mm glued joint.Guidance for specification option: Square edged boards. fermacell® Jointfiller 5–7 mm filled joint.Guidance for specification option: For site cut boards. |
Finish | Not required.fermacell® Fine Surface Treatment (FST). |
System accessories | Manufacturer guidanceUse correct accessories as per manufacturers guidelines. |
Execution | Manufacturer guidanceInstalling gypsum board linings generally. |
System completion | Verification of performance. |
Metal studs | 50 mm fermacell® studs. 75 mm fermacell® studs. 100 mm fermacell® studs. |
WallThickness | 93 mm. |
Substructure | 75 x 0.6 mm fermacell® studs. Manufacturer guidanceMax 600 mm centres. |
Board | Not applicable. Manufacturer guidanceBoarding to room size. |
Board size | 2400 x 1200 mm. 2700 x 1200 mm. 3000 x 1200 mm. |
Density | 1150+50 kg/m³. Manufacturer guidancefermacell® fibre gypsum board. |
Water vapour diffusion resistance | 13 μ. Manufacturer guidancefermacell® fibre gypsum board. |
ThermalConductivity | 0.32 λ. Manufacturer guidancefermacell® fibre gypsum board. |
SpecificHeatCapacity | 1.1 kJ/kgK. Manufacturer guidancefermacell® fibre gypsum board. |
Hardness | 30 N/mm². Manufacturer guidancefermacell® fibre gypsum board. |
ThicknessSwelling | < 2%. Manufacturer guidancefermacell® fibre gypsum board. |
Shrinkage | 0.25 mm/m. Guidance for specification option: At 30% change in relative humidity (20°C). Manufacturer guidancefermacell® fibre gypsum board. Extension/shrinkage. |
MoistureContent | 1.3%. Guidance for specification option: At 65% relative humidity at 20 °C air temperature. Manufacturer guidancefermacell® fibre gypsum board. |
pH value | 7–8. Manufacturer guidancefermacell® fibre gypsum board. |
Usage | Type 1 and 2. Guidance for specification option: Usage classification to EN 1995-1. Manufacturer guidancefermacell® fibre gypsum board. |
ThermalExpansionCoefficient | 0.0001% /K. Manufacturer guidancefermacell® fibre gypsum board. |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 100 % Guidance for specification option: Best Fermacell gypsum fibreboard contains 100% recycled content. All by-products recyclable. |