Description

Insulated, metal stud partition system based on Fermacell Powerpanel H20 linings.

General information

Uniclass 2015

Ss_25_10_30_70 Rigid sheet partition systemsPrimary

CAWS

K10/125 Metal stud partition system

K10/30 Metal stud

Specification data - Rigid sheet partition systems

Product Reference

Fermacell 1S11 H20 Insulated Partition

Metal studs

75 mm

100 mm

Lining finishes

Powerpanel Surface Finish

Tiles

Standard product features

Fire resistance:

30 minutes.

Stud centres:

600 mm.

Linings:

One layer of 12.5 mm Fermacell Powerpanel H20 to each side.

- Fixings:

35 mm Powerpanel screws at 250 mm centres.

Joint treatment:

Fermacell Jointstik 1 mm glued joint.

N.B. For Powerpanel H2O - ALL joints must be fully supported / backed.

Insulation (minimum density):

60 mm mineral wool: 25 kg/m³.

Powerpanel H2O finishing:

Tiles:-

Powerpanel Surface Finish to Powerpanel H2O Boards. All joints must also be reinforced with an alkali resistant 70 mm Glass Fibre Mesh reinforcement Tape embedded into the Powerpanel surface finish.

N.B. Tiles must NOT be fixed over Powerpanel Surface Finish.

Other requirements:

All Powerpanel H2O joints must also be reinforced with an alkali resistant 70 mm Glass Fibre Mesh reinforcement Tape embedded into the Powerpanel surface finish.

Fire stopping around service penetrations. Frame out openings with the same number of layers of board as per above specification. Sockets backed using baffle boxes, intumescent putty pads or suitable rock mineral wool, sufficient to maintain the fire/acoustic performance.

Movement joints are required at maximum 8 linear metre intervals.

Refer to manufacturer's literature. Vapour barrier as required for high humidity areas.

For tiled areas reduce studs to 400 mm centres as required. Tile adhesive to be suitable for cement based substrate.

Provide door reinforcement as required to suit door weights and opening size. Ensure no vertical joints at door jambs.

Offset all board joints by minimum 200 mm.

Product Options

Metal studs:

  • In Swimming Pool and other corrosive environments, the steel studs and associated components must have additional Corrosion Protection - e.g. C5 coating.
  • 75 mm Fermacell DIN Standard Steel (50 mm fixing face, 0.6 mm gauge).
  • 100 mm Fermacell DIN Standard Steel (50 mm fixing face, 0.6 mm gauge).

Partition performance (based on stud type):

- 75 mm stud:

  • Height (maximum) 4.75 m.
  • Thickness (overall): 100 mm.
  • Airborne sound resistance (Rw): 49 dB.

- 100 mm stud:

  • Height (maximum): 5.98 m.
  • Thickness (overall): 125 mm.
  • Airborne sound resistance (Rw): 49 dB.

Literature

Fermacell Orange Book

Fermacell Orange Book

Fermacell Product Selector

Fermacell Product Selector

Third party certifications

  • 13/5044
  • ETA
  • ECO Institute

Similar products from James Hardie Building Products Ltd

Fermacell 1S11 Insulated Partition

Fermacell 1S12 H20 Insulated Partition

Fermacell 1S13 H20 Insulated Partition