NBS Source
I'm a manufacturer

ETW 112F - Thruwall® Solutions for the Building Envelope - Non-Loadbearing SFS In-fill System

Verified by manufacturer 9 days ago

ETEX UK REMAGIN LIMITED Third party certifications:
  • Constructionline Gold

    Constructionline Gold

    Certificate type

  • ISO 9001 Quality Management

    Certificate type

  • ISO 45001 Health and Safety Management

    Certificate type

Non-loadbearing steel framing in-fill system (SFS) for the external building envelope, composed of insulation, external sheathing, light gauge steel framing and single-layer internal wall lining.

Jump to:
+44 (0)1756 701522 Website

Application

Non-loadbearing in-fill system for the external building envelope.

60 minute Thruwall® solution for medium-rise construction.

Description

Non-loadbearing steel framing in-fill system (SFS) for the external building envelope composed of insulation, external sheathing, light gauge steel framing and single-layer internal wall lining.

Features and benefits:

  • Comprises: external insulation; weather defence sheathing; Remagin light steel in-fill framing; mineral wool cavity insulation; 1 x 15 mm Fire Board internal lining
  • Fire resistance to EN 1364-1 (non-loadbearing): EI 60 minutes (inside to out/ outside to in).
  • Reaction to fire, to EN 13501-2: all components are at least A2 (Limited Combustibility); Weather Defence sheathing and glass mineral wool are A1 Non-Combustible.
  • Sound insulation to ISO 10140-2: 45 Rw dB or 40 Rw + Ctr dB.
  • Height/strength to EN 1993-1-1 varies by wind and cladding loading.
  • U-value varies by framing specification; indicative values available.

Application-specific linings also available consult manufacturer for details.

External Sheathing Weather Defence:

  • Fully non-combustible (Euroclass A1) so is suitable for buildings with a height more than 18 metres.
  • Has two BBA certificates.
  • Can be left fully exposed on-site for up to 12 months.
  • Dimensionally stable, which means boards can be butted tightly together providing exceptional levels of airtightness.
  • Eliminates the need for a breather membrane.
  • 50% faster to install than traditional cement particle board.
  • Lightweight.
  • Easy to cut, shape and bend offering more options for design detailing.

Steel Frame Systems (SFS):

  • The fully-engineered steel frame system (SFS) is custom designed according to the specific requirements of any project.
  • All sections are delivered cut to length – zero cutting or wastage on site.
  • Factory-assured standards of quality.
  • Colour coded and individually labelled.
  • Lightweight.

Internal Wall Lining:

  • 15 mm Fire Board.

General information

Color

Silver

Grey

Finish

Smooth

Material

Glass mineral wool

Rock mineral wool

Steel

Plasterboard

Shape

Rectangle

Square

Other

Width

89 mm

100 mm

150 mm

200 mm

250 mm

Show more

Height

Bespoke

Warranty description

30 year

Guidance for specification option:

Full detail available from the manufacturer on request.

Uniclass

Ss_25_10_32_45 Light steel wall framing systemsPrimary

CAWS

G10/20 Steel framing system

G10/150 Steel framing system

SKU Code

ETW 112F

Specification data - Light steel wall framing systems

System performance

Guidance for specification option:

Insert requirements or omit.

Framing members

Remagin light steel in-fill framing.

Connections

-

Connection fasteners

Guidance for specification option:

Insert requirements.

Connection accessories

Guidance for specification option:

Insert requirements or omit.

Anchors to concrete and masonry

-

Type of anchor

Guidance for specification option:

Insert requirements.

Fixings

Guidance for specification option:

Insert requirements.

Means of adjustment

Guidance for specification option:

Insert requirements or omit.

Insulation

External: 100 mm rock mineral wool.
Cavity insulation: Full-fill glass mineral wool.

Manufacturer guidance

Thermal conductivity: all insulation is 0.035 W/m·K.

Sheathing board

1 x 12.5 mm Weather Defence board.

Lining

1 x 15 mm Fire Board.

Manufacturer guidance

Other linings available, consult manufacturer for details.

  • Megadeco (for faster decoration and impact-resistance);
  • Aqua Board (for wet areas);
  • LaDura (for impact and durability).

Fire resistance

Fire resistance to EN 1364-1 (non-loadbearing), EI 60 mins (inside to out); EI 60 mins (outside to in).

Reaction to fire

To EN 13501-2:
All components: at least A2 Limited Combustibility;
Weather Defence sheathing: A1 Non-Combustible;
Glass mineral wool: A1 Non-Combustible.

System U-value

Varies by framing specification.

Guidance for specification option:

To BR443 and BRE465 (excluding cladding and fixing correction).

Manufacturer guidance

Indicative values:

  • 0.20 W/m²K: studs 100 x 1.2 at 600 mm centres.
  • 0.24 W/m²K: studs 100 x 1.6 at 300 mm centres.
  • 0.18 W/m²K: studs 150 x 1.2 at 600 mm centres.
  • 0.23 W/m²K: studs 150 x 1.6 at 300 mm centres.

Sound insulation

To ISO 10140-2, 45 Rw dB or 40 Rw + Ctr dB.

Performance characteristics

Height/ strength to EN 1993-1-1 varies by wind and cladding loading.

Guidance for specification option:

Consult manufacturer's literature for details.

Sustainability data

Contains Red List materials

No

Country of material origin

Europe

Country of product manufacture

United Kingdom

Manufacturing plant location

Material

Glass mineral wool
Rock mineral wool
Steel
Plasterboard

Recyclability

95%

Recycled content

As defined in clause 7.8 of BS EN ISO 14021

45 %

Expected Life

60 year

Third party certifications

Constructionline Gold

Constructionline Gold

Construction Line Gold

ISO 9001 Quality Management

ISO 9001 Quality Management

ISO 9001 Quality Management

ISO 45001 Health and Safety Management

ISO 45001 Health and Safety Management

ISO 45001 Health & Safety Management System

Literature

Remagin SFS System Manual

Remagin SFS System Manual

Thruwall® Solutions Brochure

Thruwall® Solutions Brochure

Case studies

Thomas Keble School

Thomas Keble School

Similar products from ETEX UK REMAGIN LIMITED

ETW 113D - Thruwall® Solutions for the Building Envelope - Non-Loadbearing SFS In-fill System

ETW 113D - Thruwall® Solutions for the Building Envelope - Non-Loadbearing SFS In-fill System

ETW 114F - Thruwall® Solutions for the Building Envelope - Non-Loadbearing SFS In-fill System

ETW 114F - Thruwall® Solutions for the Building Envelope - Non-Loadbearing SFS In-fill System

ETW 134F - Thruwall® Solutions for the Building Envelope - Non-Loadbearing SFS In-fill System

ETW 134F - Thruwall® Solutions for the Building Envelope - Non-Loadbearing SFS In-fill System

ETW 213D - Thruwall® Solutions for the Building Envelope - Non-Loadbearing SFS In-fill System

ETW 213D - Thruwall® Solutions for the Building Envelope - Non-Loadbearing SFS In-fill System