NBS Source
I'm a manufacturer
Compare variants

Energy SAVER COMPACT - Kits for Metering

Verified by manufacturer 3 months ago

KCX700CD ¾” 850 l/h - No Case

PETTINAROLI UK LIMITED Variant:
Third party certifications:
  • ISO 9001 Quality Management

    Certificate type

  • ISO 14001 Environmental Management Systems

    Certificate type

Prefabricated kits for hydronic balancing and energy consumption metering applications in district/centralised heating and cooling systems.

Jump to:
0121 3582012 Website

Application

The product is designed as an energy metering for the billing of water installations in domestic or commercial areas. The ultrasonic energy meter is mounted onto an 80mm flushing bypass for effective cleaning of the system pre-commissioning and also incorporates a Filterball, combined filter and isolation valve, on the flow to protect the unit. The unit has full isolation capabilities allowing for easy maintenance of the terminal units and system components.



integrated flushing bypass and commissioning set for heating/ cooling and hot water systems.

Description

An energy meter supplied with a prefabricated and 100% tested flushing bypass kit for hydronic balancing, flushing and consumption metering in heating and cooling systems.


Functions:

  • Adjustable design flow rate that remains constant even with variations in the other circuits thanks to the PICV ;
  • 80mm Flushing bypass for the effective flushing of the circuit.
  • Full isolation of the terminal unit with the purpose to carry out cleaning and/or maintenance operations on the system;
  • Implementing a system for accounting the energy exchanged by the terminal unit, both with the purpose of simple measurement or actual billing of consumption.


Energy SAVER COMPACT comprises:

  1. Dynasty pressure independent control valve for heavily contaminated water, with the suitable actuator (thermoelectric or electromechanical).
  2. Pettinaroli heating and cooling thermal Energy Meter.
  3. FilterBall (isolation valve with integrated filter included)
  4. 80mm Flushing By-pass
  5. Isolation valves.

General information

Color

Gold

White

Finish

Brass

Material

Brass

Plastic

Shape

Other

Length

Bespoke

318 mm

325 mm

364 mm

388 mm

Width

138 mm

Height

Bespoke

95 mm

91 mm

96 mm

Warranty description

Five year

Guidance for specification option:

Consult manufacturer for details.

Uniclass

Pr_65_54_95_63 Pressure-independent control valvesPrimary

CAWS

S90/650 Flow-reducing/ servicing valves

Specification data - Pressure-independent control valves

Pressure rating

PN25.

Temperature range

-10 to 100°C.

Guidance for specification option:

No frost and no steam. Under 0°C, glycol must be added. For temperature limits of the actuators and flexible hoses see their dedicated technical specifications.

Material

Brass body.

Connections

3/4 x 1/2 inch BSP.

Manufacturer guidance

Terminal unit side: Flat-end male connections.

System side: Rp female connections made via union.

Actuator

Electromechanical RVAZ2.

Guidance for specification option:

  • Type of control: ON/OFF or three points.
  • Supply voltage: 120/230 V a.c. or 24 V a.c./d.c. (to specify).
  • Stroke: 8.5 mm (47 s).
  • Additional features: autostroke.
  • Fluid temperature: 0–95°C.
  • Ambient temperature: 0–50°C.
  • Adapter (not included): 0A7010 or 0A748X.

Electromechanical VA7481.

Guidance for specification option:

Insert requirements where appropriate:

  • Type of control: ON/OFF or three points.
  • Supply voltage: 230 V a.c. or 24 V a.c./d.c.
  • Stroke: 6.3 mm (50.4 s).
  • Fluid temperature: 0–95°C.
  • Ambient temperature: 0–50°C.
  • Adapter (not included): 0A7010 or 0A748X.

Electromechanical VA7483.

Guidance for specification option:

Insert requirements where appropriate:

  • Type of control: proportional 0–10 V.
  • Supply voltage: 24 V a.c./d.c.
  • Stroke: 6.3 mm (50.4 s).
  • Fluid temperature: 0–95°C.
  • Ambient temperature: 0–50°C.
  • Adapter (not included): 0A7010 or 0A748X.

Electromechanical VA7484.

Guidance for specification option:

Insert requirements where appropriate:

  • Type of control: proportional 0–10 V.
  • Supply voltage: 24 V a.c./d.c.
  • Stroke: 6.3 mm (50.4 s).
  • Fluid temperature: 0–95°C.
  • Ambient temperature: 0–50°C.
  • Adapter (not included): 0A7010 or 0A748X.

Thermoelectric A542O4.

Guidance for specification option:

  • Type of control: ON/OFF or PWM.
  • Supply voltage: 230 V a.c.
  • Stroke: 4 mm (≈210 s).
  • Additional features: micro switch.
  • Fluid temperature: 0–100°C.
  • Ambient temperature: 0–60°C.
  • Adapter: VA64 (included).

Thermoelectric A544O4.

Guidance for specification option:

  • Type of control: ON/OFF or PWM.
  • Supply voltage: 24 V a.c./d.c.
  • Stroke: 4 mm (≈210 s).
  • Additional features: micro switch.
  • Fluid temperature: 0–100°C.
  • Ambient temperature: 0–60°C.
  • Adapter: VA64 (included).

Thermoelectric A544P3.

Guidance for specification option:

  • Type of control: proportional 0–10V.
  • Supply voltage: 24 V a.c.
  • Stroke: 4 mm (≈120 s).
  • Fluid temperature: 0–100°C.
  • Ambient temperature: 0–60°C.
  • Adapter: VA64 (included).

Thermoelectric MT541O2.

Guidance for specification option:

  • Type of control: ON/OFF
  • Supply voltage: 115 V a.c.
  • Stroke: 4 mm (≈180 s).
  • Fluid temperature: -5 to 100°C.
  • Ambient temperature: -5 to 50°C.
  • Adapter: 0A7010 (included).

Thermoelectric V54202.

Guidance for specification option:

  • Type of control: ON/OFF or PWM.
  • Supply voltage: 230 V a.c.
  • Stroke: 4 mm (≈180 s).
  • Fluid temperature: 0–100°C.
  • Ambient temperature: 0–60°C.
  • Adapter: VA64 (included).

Thermoelectric V54402.

Guidance for specification option:

  • Type of control: ON/OFF or PWM.
  • Supply voltage: 24 V a.c./d.c.
  • Stroke: 4 mm (≈210 s).
  • Fluid temperature: 0–100°C.
  • Ambient temperature: 0–60°C.
  • Adapter: VA64 (included).

Manufacturer guidance

Consult manufacturer for further details including compatible kits.

Accessories

Connection union, 1007W, F flat seat x M ISO 228, ¾ x ¾”.

Connection union, 1007WF, F flat seat x F flat seat, ¾ x ¾”.

Connection union, 1007Z, F flat seat x M ISO 226, ¾ x ½“.

Connection union, 701CR, F flat seat x M ISO 226, ¾ x ½”.

EvoFLEX flexible hoses, FXMUP, F flat end x M ISO 228.

Guidance for specification option:

Available in different lengths, (200–2000 mm) and different nominal diameters. Insert requirements.

  • ¾ x ½”: For kits up to 1850 L/h (DN13, DN15).
  • ¾ x ¾”: For all the kits (DN13, DN15, DN19).

EvoFLEX flexible hoses, FXUPUP, F flat end x F flat end.

Guidance for specification option:

Available in different lengths, (200–2000 mm) and different nominal diameters. Insert requirements.

  • ¾ x ½”: For kits up to 1850 L/h (DN13, DN15).
  • ¾ x ¾”: For all the kits (DN13, DN15, DN19).

Pressure ports.

Manufacturer guidance

Connection unions

  • Brass-made unions that can be used on the terminal unit side to facilitate connection operations of the kit Energy SAVER Compact.

EvoFLEX flexible hoses

  • Connecting synthetic rubber (EPDM) hoses covered with a stainless steel braid (AISI 304) to connect two pipe sections.
  • Can be used on the terminal unit side to facilitate connection operations of the kit Energy SAVER Compact.

Pressure ports

  • Fast plug pressure ports for fluid pressure and temperature measurements. Equipped with an appropriate internal sealing gasket and suitable for the insertion of needle-type sensors with a maximum diameter of 3 mm.
  • Can be installed on the PICV DYNASTY 92-1 in place of the relevant caps. This way it is possible to measure the pressure difference present at the ends of the valve and verify that it has reached the start-up value.


FlowRateRange

<600 L/h.

600–850 L/h.

WorkingPressureRange

30–600 kPa.

Guidance for specification option:

Minimum depends on PICV and setting.

Manufacturer guidance

Working differential pressure range.

Integral accessories

EM303 energy meter.

Guidance for specification option:

  • Calculator protection class: IP65.
  • Communication protocol: M-bus via cable / M-bus Wireless.
  • Available in three nominal flow rates: 0.6 m³/h, 1.5 m³/h, and 2.5 m³/h. This value must be higher than the nominal flow rate of the kit desired. For further information refer to Technical Specifications KCX700CD – KCX700CDG.

EM403 energy meter.

Guidance for specification option:

  • Calculator protection class: IP54.
  • Communication protocol: M-bus via cable / M-bus Wireless / MODBUS / LoRaWan / BACnet.
  • Available in three nominal flow rates: 0.6 m³/h, 1.5 m³/h, and 2.5 m³/h. This value must be higher than the nominal flow rate of the kit desired. For further information refer to Technical Specifications KCX700CD – KCX700CDG.

Manufacturer guidance

Pettinaroli ultrasonic energy meter for heating and cooling applications certified according to MID directive (Measurement Instruments Directive 2014/32/EU).


Common features:

  • Male threaded flat face connections.
  • Flow sensor protection class: IP68.
  • Medium in flow sensor: Water.
  • Nominal pressure: PN25.
  • Meter body: CW602N brass.
  • Temperature sensor cables: 1.5 m.
  • Connection cables: 1.5 m.

Sustainability data

Contains Red List materials

Yes

Country of material origin

Italy

Country of product manufacture

Italy

Material

Brass

Plastic

Manufacturing plant location

Expected Life

15 year

Third party certifications

BIM objects

Platform Compatible Version
Revit
-

1

Third party certifications

ISO 9001 Quality Management

ISO 9001 Quality Management

BSI 9001:2015

ISO 14001 Environmental Management Systems

ISO 14001 Environmental Management Systems

ISO14001:2015 - Environmental Management System

Literature

Energy SAVER

Energy SAVER

Technical Specifications KCX700CD – KCX700CDG rev.01

Technical Specifications KCX700CD – KCX700CDG rev.01

Technical Specifications KCX700CD – KCX700CDG

Technical Specifications KCX700CD – KCX700CDG

7021 - Mixing Shunt for Hydronics underfloor heating

7021 - Mixing Shunt for Hydronics underfloor heating

Similar products from PETTINAROLI UK LIMITED

83 Range PICV - Pressure Independent Control Valve

83 Range PICV - Pressure Independent Control Valve

92 Range PICV

92 Range PICV

94 Range PICV - Pressure Independent Control Valve

94 Range PICV - Pressure Independent Control Valve

VORTEX 4 ePIV Terminal Valve Assembly

VORTEX 4 ePIV Terminal Valve Assembly

VORTEX 4 PICV Compact Terminal Valve Assembly

VORTEX 4 PICV Compact Terminal Valve Assembly

VORTEX 4 PICV Compact Terminal Valve Assembly (Strainer)