Application

Suitable for commercial and offices, distribution centres, education, industrial, mechanical, retail and transport applications.

Description

Euroclad Elite 4 Range offers a low pitch standing seam roof option, with no endlaps and no exposed fixings.


The Euroseam® profile sheet can be used to achieve a whole range of curves from large barrel vaults to multiple curved designs. The Euroseam® profile can be supplied in natural stucco embossed aluminium, pre-painted PVDF, ARS, Duragloss or Organic Patina.


Features and benefits:

  • 0.9 mm EC 75-400 Euroseam external aluminium sheet.
  • 0.7 mm EC 32-200-1000 Liner MW5 steel liner sheet (non-perforated or perforated).
  • Quattro Spacer System featuring Quattro Bar, Quattro Bracket and Halters.
  • 0.040λ (Lambda) quilt insulation.
  • External aluminium sheet available in a range of coatings, finishes and colours.

General information

Finish

Coated

Material

Glass mineral wool

Mineral wool

Aluminium

Shape

Other

Guidance for specification option:

Standing seam.

Length

Bespoke

Width

Bespoke

Height

Bespoke

Warranty description

25 year

Guidance for specification option:

Guaranteed for up to 30 years with the Elite Plus system guarantee.

Uniclass

Ss_30_40_65_50 Metal profiled sheet self-supporting roof covering systemsPrimary

CAWS

H31/10 Metal

H31/120 Metal

Specification data - Metal profiled sheet self-supporting roof covering systems

System performance

External sheet coating fire performance: To BS EN 13501-5:2016, BROOF(T4).

Guidance for specification option:

By Commission Decision 2000/553/EC.

Liner sheets

-

Material

EC 32-200-1000 Liner MW5.

EC 32-200-1000 Liner MW5 Swaged 0.7 mm steel.

Primary fasteners

Carbon steel fixings.

Guidance for specification option:

Elite guarantee.

Stainless steel fixings.

Guidance for specification option:

Elite PLUS guarantee.

End and side laps

Not required.

Air and vapour control layer

-

Material

Euroclad Elite VCL.

Sealing

Euroclad Elite VCL Sealing Tape.

Euroclad Elite HH VCL Sealing Tape.

Spacers

Quattro Bar and 80 mm Quattro Bracket.

Guidance for specification option:

System depth: 194.70 mm.

System weight: 15.09 kg/m².

U-value: NPD.

Quattro Bar and 100 mm Quattro Bracket.

Guidance for specification option:

System depth: 214.70 mm.

System weight: 15.64 kg/m².

U-value: 0.34 W/m²K.

Quattro Bar and 120 mm Quattro Bracket.

Guidance for specification option:

System depth: 234.70 mm.

System weight: 16.19 kg/m².

U-value: 0.30 W/m²K.

Quattro Bar and 140 mm Quattro Bracket.

Guidance for specification option:

System depth: 254.70 mm.

System weight: 16.74 kg/m².

U-value: 0.26 W/m²K.

Quattro Bar and 150 mm Quattro Bracket.

Guidance for specification option:

System depth: 264.70 mm.

System weight: 16.75 kg/m².

U-value: 0.25 W/m²K.

Sound reduction: To BS EN ISO 10140-2:2010, 39 dB (-2;-8)(C/22349/T01).

Quattro Bar and 160 mm Quattro Bracket.

Guidance for specification option:

System depth: 274.70 mm.

System weight: 17.29 kg/m².

U-value: 0.23 W/m²K.

Quattro Bar and 170 mm Quattro Bracket.

Guidance for specification option:

System depth: 284.70 mm.

System weight: 17.30 kg/m².

U-value: 0.22 W/m²K.

Quattro Bar and 180 mm Quattro Bracket.

Guidance for specification option:

System depth: 294.70 mm.

System weight: 17.85 kg/m².

U-value: 0.21 W/m²K.

Quattro Bar and 185 mm Quattro Bracket.

Guidance for specification option:

System depth: 299.70 mm.

System weight: 17.85 kg/m².

U-value: 0.20 W/m²K.

Quattro Bar and 200 mm Quattro Bracket.

Guidance for specification option:

System depth: 314.70 mm.

System weight: 18.40 kg/m².

U-value: 0.19 W/m²K.

Quattro Bar and 220 mm Quattro Bracket.

Guidance for specification option:

System depth: 334.70 mm.

System weight: 18.95 kg/m².

U-value: 0.18 W/m²K.

Sound reduction: To BS EN ISO 10140-2:2010, 42 dB (-2;-8)(C/22349/T01).

Quattro Bar and 240 mm Quattro Bracket.

Guidance for specification option:

System depth: 354.70 mm.

System weight: 19.50 kg/m².

U-value: 0.16 W/m²K.

Quattro Bar and 260 mm Quattro Bracket.

Guidance for specification option:

System depth: 374.70 mm.

System weight: 20.05 kg/m².

U-value: 0.15 W/m²K.

Sound reduction: To BS EN ISO 10140-2:2010, 43 dB (-2;-7)(C/22349/T01).

Quattro Bar and 280 mm Quattro Bracket.

Guidance for specification option:

System depth: 394.70 mm.

System weight: 20.60 kg/m².

U-value: 0.14 W/m²K.

Quattro Bar and 300 mm Quattro Bracket.

Guidance for specification option:

System depth: 414.70 mm.

System weight: 21.16 kg/m².

U-value: 0.13 W/m²K.

Quattro Bar and 320 mm Quattro Bracket.

Guidance for specification option:

System depth: 434.70 mm.

System weight: 21.71 kg/m².

U-value: 0.13 W/m²K.

Quattro Bar and 340 mm Quattro Bracket.

Guidance for specification option:

System depth: 454.70 mm.

System weight: 22.26 kg/m².

U-value: 0.12 W/m²K.

Quattro Bar and 360 mm Quattro Bracket.

Guidance for specification option:

System depth: 474.70 mm.

System weight: 22.81 kg/m².

U-value: 0.11 W/m²K.

Quattro Bar and 380 mm Quattro Bracket.

Guidance for specification option:

System depth: 494.70 mm.

System weight: 23.36 kg/m².

U-value: 0.11 W/m²K.

Quattro Bar and 400 mm Quattro Bracket.

Guidance for specification option:

System depth: 514.70 mm.

System weight: 23.91 kg/m².

U-value: 0.10 W/m²K.

Thermal insulation

Knauf Factoryclad 40.

Rockwool Cladding Roll.

Manufacturer guidance

Declared lambda: 0.040 W/mK.

External sheets

-

Material

EC 75-400 Euroseam 0.9 mm aluminium plain mill stucco embossed.

EC 75-400 Euroseam 0.9 mm aluminium PVDF.

EC 75-400 Euroseam 0.9 mm aluminium ARS.

EC 75-400 Euroseam 0.9 mm aluminium organic patina.

Primary fasteners

Carbon steel fixings.

Guidance for specification option:

Elite guarantee.

Stainless steel fixings.

Guidance for specification option:

Elite PLUS guarantee.

System accessories

Fasteners

Standard U-value rooflights.

Flashings.

Membranes.

Non-penetrative clamps.

Guidance for specification option:

For attachment of PV arrays and other roof mounted installations such as walkways.

Tapes.

Mastic and sealants.

Fabrications.

PV solutions.

Fall arrest and fall restraint.

Roof penetrations.

Manufacturer guidance

Consult manufacturer for details.

Similar products from Euroclad Group Ltd

Elite 1 - Roof System

Elite 1 - Roof System

Elite 10 - Roof System

Elite 10 - Roof System

Elite 11 - Roof System

Elite 11 - Roof System

Elite 2 - Roof System

Elite 2 - Roof System

Elite 2 AC2 - Roof System

Elite 2 AC2 - Roof System

Elite 3 - Roof System

Elite 3 - Roof System

Elite 3 AC2 - Roof System

Elite 3 AC2 - Roof System

Elite 4 AC2 - Roof System

Elite 4 AC2 - Roof System

Elite 5 - Roof System

Elite 5 - Roof System

Elite 5 AC1 - Roof System

Elite 5 AC1 - Roof System