Verified by manufacturer 10 months ago
Insulated built-up roof system with a EC 54-500 secret fix external profile.
Suitable for commercial and offices, distribution centres, education, industrial, mechanical, retail and transport applications.
Euroclad Elite 3 Range provides a low pitch roofing solution with continuous outer sheets featuring no endlaps and no exposed fixings.
A number of designs can be achieved offering a wide range of U-values. The SF500 roofing sheet can used on curved roofs with a minimum radius of 50 metres, which allows ridge heights to be kept to a minimum for a clean low impact roofline.
Features and benefits:
Color | Black White Grey Beige Blue |
Finish | Coated |
Material | Steel Glass mineral wool Mineral wool |
Length | Bespoke |
Width | Bespoke |
Height | Bespoke |
Warranty description | 25 year Guidance for specification option: Guaranteed for up to 30 years with the Elite Plus system guarantee. |
Uniclass | |
CAWS | H31/10 Metal H31/120 Metal |
System performance | External sheet coating fire performance: To BS EN 13501-5:2016, BROOF(T4).Guidance for specification option: Colorcoat HPS200 Ultra: By physical testing. Other coating options are available on request. |
Liner sheets | |
Material | EC 32-200-1000 Liner MW5.EC 32-200-1000 Liner MW5 Swaged 0.7 mm steel. |
Primary fasteners | Carbon steel fixings.Guidance for specification option: Elite guarantee. Stainless steel fixings.Guidance for specification option: Elite PLUS guarantee. |
End and side laps | Not required. |
Air and vapour control layer | |
Material | Euroclad Elite VCL.Euroclad Elite HH VCL. |
Sealing | Euroclad Elite VCL Sealing Tape.Euroclad Elite HH VCL Sealing Tape. |
Spacers | Quattro Bar and 80 mm Quattro Bracket.Guidance for specification option: System depth: 134.70 mm. System weight: 17.28 kg/m². U-value: NPD. Quattro Bar and 100 mm Quattro Bracket.Guidance for specification option: System depth: 154.70 mm. System weight: 17.83 kg/m². U-value: 0.49 W/m²K. Quattro Bar and 120 mm Quattro Bracket.Guidance for specification option: System depth: 174.70 mm. System weight: 18.39 kg/m². U-value: 0.40 W/m²K. Quattro Bar and 140 mm Quattro Bracket.Guidance for specification option: System depth: 194.70 mm. System weight: 18.94 kg/m². U-value: 0.34 W/m²K. Quattro Bar and 150 mm Quattro Bracket.Guidance for specification option: System depth: 204.70 mm. System weight: 19.48 kg/m². U-value: 0.31 W/m²K. Quattro Bar and 160 mm Quattro Bracket.Guidance for specification option: System depth: 214.70 mm. System weight: 19.49 kg/m². U-value: 0.29 W/m²K. Quattro Bar and 170 mm Quattro Bracket.Guidance for specification option: System depth: 224.70 mm. System weight: 20.04 kg/m². U-value: 0.27 W/m²K. Quattro Bar and 180 mm Quattro Bracket.Guidance for specification option: System depth: 234.70 mm. System weight: 20.04 kg/m². U-value: 0.26 W/m²K. Quattro Bar and 185 mm Quattro Bracket.Guidance for specification option: System depth: 239.70 mm. System weight: 20.58 kg/m². U-value: 0.25 W/m²K. Quattro Bar and 200 mm Quattro Bracket.Guidance for specification option: System depth: 254.70 mm. System weight: 20.59 kg/m². U-value: 0.23 W/m²K. Quattro Bar and 220 mm Quattro Bracket.Guidance for specification option: System depth: 274.70 mm. System weight: 21.14 kg/m². U-value: 0.21 W/m²K. Quattro Bar and 240 mm Quattro Bracket.Guidance for specification option: System depth: 294.70 mm. System weight: 21.70 kg/m². U-value: 0.19 W/m²K. Quattro Bar and 260 mm Quattro Bracket.Guidance for specification option: System depth: 314.70 mm. System weight: 22.25 kg/m². U-value: 0.18 W/m²K. Sound reduction: To BS EN ISO 10140-2:2010, 47 dB (-2;-6)(C/22349/T02). Quattro Bar and 280 mm Quattro Bracket.Guidance for specification option: System depth: 334.70 mm. System weight: 22.80 kg/m². U-value: 0.17 W/m²K. Quattro Bar and 300 mm Quattro Bracket.Guidance for specification option: System depth: 354.70 mm. System weight: 23.35 kg/m². U-value: 0.15 W/m²K. Sound reduction: To BS EN ISO 10140-2:2010, 50 dB (-2;-5) (C/22349/T02). Quattro Bar and 320 mm Quattro Bracket.Guidance for specification option: System depth: 374.70 mm. System weight: 23.90 kg/m². U-value: 0.14 W/m²K. Quattro Bar and 340 mm Quattro Bracket.Guidance for specification option: System depth: 394.70 mm. System weight: 24.45 kg/m². U-value: 0.13 W/m²K. Quattro Bar and 360 mm Quattro Bracket.Guidance for specification option: System depth: 414.70 mm. System weight: 25.01 kg/m². U-value: 0.13 W/m²K. Quattro Bar and 380 mm Quattro Bracket.Guidance for specification option: System depth: 434.70 mm. System weight: 25.56 kg/m². U-value: 0.12 W/m²K. Quattro Bar and 400 mm Quattro Bracket.Guidance for specification option: System depth: 454.70 mm. System weight: 26.11 kg/m². U-value: 0.11 W/m²K. |
Thermal insulation | Knauf Factoryclad 40.Rockwool Cladding Roll.Manufacturer guidanceDeclared lambda: 0.040 W/mK. |
External sheets | |
Material | EC 54-500 Secret Fix 0.7 mm steel Colorcoat HPS200 Ultra®.EC 54-500 Secret Fix 0.7 mm steel Colorcoat Prisma®. |
Primary fasteners | Carbon steel fixings.Guidance for specification option: Elite guarantee. Stainless steel fixings.Guidance for specification option: Elite PLUS guarantee. |
System accessories | FastenersStandard U-value rooflights.Flashings.Membranes.Non-penetrative clamps.Guidance for specification option: For attachment of PV arrays and other roof mounted installations such as walkways. Tapes.Mastic and sealants.Fabrications.PV solutions.Fall arrest and fall restraint.Roof penetrations.Manufacturer guidanceConsult manufacturer for details. |