Insulated built-up roof with an EC 75-400 Euroseam external profile.
Suitable for commercial and offices, distribution centres, education, industrial, mechanical, retail and transport applications.
Euroclad Elite 4 Range offers a low pitch standing seam roof option, with no endlaps and no exposed fixings.
The Euroseam® profile sheet can be used to achieve a whole range of curves from large barrel vaults to multiple curved designs. The Euroseam® profile can be supplied in natural stucco embossed aluminium, pre-painted PVDF, ARS, Duragloss or Organic Patina.
Elite 4 AC2 focuses on sound absorption and features a perforated EC 32-200-1000 Liner MW5 profile and acoustic insulation batts.
Features and benefits:
Finish | Coated |
Material | Glass mineral wool Mineral wool Aluminium |
Shape | Other Guidance for specification option: Standing seam. |
Length | Bespoke |
Width | Bespoke |
Height | Bespoke |
Warranty description | 25 year Guidance for specification option: Guaranteed for up to 30 years with the Elite Plus system guarantee. |
Uniclass | |
CAWS | H31/10 Metal H31/120 Metal |
System performance | External sheet coating fire performance: To BS EN 13501-5:2016, BROOF(T4).Guidance for specification option: By Commission Decision 2000/553/EC. |
Liner sheets | |
Material | EC 32-200-1000 Liner MW5 - perforated.EC 32-200-1000 Liner MW5 Swaged 0.7 mm steel - perforated. |
Primary fasteners | Carbon steel fixings.Guidance for specification option: Elite guarantee. Stainless steel fixings.Guidance for specification option: Elite PLUS guarantee. |
End and side laps | Not required. |
Air and vapour control layer | |
Material | Euroclad Elite VCL.Euroclad Elite HH VCL. |
Sealing | Euroclad Elite VCL Sealing Tape.Euroclad Elite HH VCL Sealing Tape. |
Spacers | Quattro Bar and 80 mm Quattro Bracket.Guidance for specification option: System depth: 194.70 mm. System weight: 14.56 kg/m². U-value: NPD. Quattro Bar and 100 mm Quattro Bracket.Guidance for specification option: System depth: 214.70 mm. System weight: 15.11 kg/m². U-value: 0.34 W/m²K. Quattro Bar and 120 mm Quattro Bracket.Guidance for specification option: System depth: 234.70 mm. System weight: 15.66 kg/m². U-value: 0.30 W/m²K. Quattro Bar and 140 mm Quattro Bracket.Guidance for specification option: System depth: 254.70 mm. System weight: 16.21 kg/m². U-value: 0.26 W/m²K. Quattro Bar and 150 mm Quattro Bracket.Guidance for specification option: System depth: 264.70 mm. System weight: 16.76 kg/m². U-value: 0.25 W/m²K. Sound reduction: To BS EN ISO 10140-2:2010, 37 dB (-1;-6)(C/22349/T01). Quattro Bar and 160 mm Quattro Bracket.Guidance for specification option: System depth: 274.70 mm. System weight: 16.77 kg/m². U-value: 0.23 W/m²K. Quattro Bar and 170 mm Quattro Bracket.Guidance for specification option: System depth: 284.70 mm. System weight: 17.31 kg/m². U-value: 0.22 W/m²K. Quattro Bar and 180 mm Quattro Bracket.Guidance for specification option: System depth: 294.70 mm. System weight: 17.32 kg/m². U-value: 0.21 W/m²K. Quattro Bar and 185 mm Quattro Bracket.Guidance for specification option: System depth: 299.70 mm. System weight: 17.86 kg/m². U-value: 0.20 W/m²K. Quattro Bar and 200 mm Quattro Bracket.Guidance for specification option: System depth: 314.70 mm. System weight: 18.41 kg/m². U-value: 0.19 W/m²K. Quattro Bar and 220 mm Quattro Bracket.Guidance for specification option: System depth: 334.70 mm. System weight: 18.96 kg/m². U-value: 0.18 W/m²K. Quattro Bar and 240 mm Quattro Bracket.Guidance for specification option: System depth: 354.70 mm. System weight: 19.51 kg/m². U-value: 0.16 W/m²K. Quattro Bar and 260 mm Quattro Bracket.Guidance for specification option: System depth: 374.70 mm. System weight: 20.06 kg/m². U-value: 0.15 W/m²K. Rain noise: To BS EN ISO 140-18:2006, 48.3 dB LIA(C/22934/T01a). Quattro Bar and 280 mm Quattro Bracket.Guidance for specification option: System depth: 394.70 mm. System weight: 20.62 kg/m². U-value: 0.14 W/m²K. Quattro Bar and 300 mm Quattro Bracket.Guidance for specification option: System depth: 414.70 mm. System weight: 21.17 kg/m². U-value: 0.13 W/m²K. Quattro Bar and 320 mm Quattro Bracket.Guidance for specification option: System depth: 434.70 mm. System weight: 21.72 kg/m². U-value: 0.13 W/m²K. Quattro Bar and 340 mm Quattro Bracket.Guidance for specification option: System depth: 454.70 mm. System weight: 22.27 kg/m². U-value: 0.12 W/m²K. Quattro Bar and 360 mm Quattro Bracket.Guidance for specification option: System depth: 474.70 mm. System weight: 22.82 kg/m². U-value: 0.11 W/m²K. Quattro Bar and 380 mm Quattro Bracket.Guidance for specification option: System depth: 494.70 mm. System weight: 23.37 kg/m². U-value: 0.11 W/m²K. Quattro Bar and 400 mm Quattro Bracket.Guidance for specification option: System depth: 514.70 mm. System weight: 23.93 kg/m². U-value: 0.10 W/m²K. |
Acoustic insulation | Elite AC2 Acoustic Trough Infills. |
Thermal insulation | Knauf Factoryclad 40.Rockwool Cladding Roll.Manufacturer guidanceDeclared lambda: 0.040 W/mK. |
External sheets | |
Material | EC 75-400 Euroseam 0.9 mm aluminium plain mill stucco embossed.EC 75-400 Euroseam 0.9 mm aluminium PVDF.EC 75-400 Euroseam 0.9 mm aluminium ARS.EC 75-400 Euroseam 0.9 mm aluminium organic patina. |
Primary fasteners | Carbon steel fixings.Guidance for specification option: Elite guarantee. Stainless steel fixings.Guidance for specification option: Elite PLUS guarantee. |
System accessories | FastenersStandard U-value rooflights.Flashings.Membranes.Non-penetrative clamps.Guidance for specification option: For attachment of PV arrays and other roof mounted installations such as walkways. Tapes.Mastic and sealants.Fabrications.PV solutions.Fall arrest and fall restraint.Roof penetrations.Manufacturer guidanceConsult manufacturer for details. |