NBS Source
I'm a manufacturer

Ecopad Thermal Break - A2 Fire Rated Thermal Break

Verified by manufacturer 18 days ago

Cladmate Facade Systems

A2 fire-rated thermal break providing low thermal conductivity and high compressive strength.

Jump to:
+44 020 3949 8826 Website

Application

Thermal break for use between flanged vertical and horizontal connections; compliant for use on buildings over 11 metres. Suitable for use with:

  • Steel to steel, masonry/ concrete or timber.
  • Concrete to concrete.
  • Between structural frames.
  • Façade system connections to substrate.
  • In isolation of sub-structure and basement elements.
  • Roof parapets.
  • Canopies.
  • Balconies.
  • External access systems.
  • With roof plant enclosures.
  • Through connections to existing substructures.
  • In connection of external and internal primary building elements.

Description

A2 fire-rated thermal break providing low thermal conductivity and high compressive strength between flanged vertical and horizontal connections.


Features and benefits:

  • Made of reinforced fire-resistant 5 mm-thick thermoset resin.
  • Maintains its structural integrity in the event of fire.
  • Low heat conductivity.
  • Low water absorption.
  • Good hydrocarbon stability.
  • Good chemical stability.
  • Excellent mechanical durability.
  • Meets multiple requirements of designers by providing all the necessary properties in one thermal break product.
  • Under “Document B Building Regulations” , this material is compliant for use on buildings over 11 metres.
  • Suitable for use with a wide range of substrates/ systems.
  • Independently tested and meets following industry standards:
  • Can be supplied as cut pads to fit in any shape within the parameters of the material.
  • A2 fire rated non-combustible.
  • Very high structural performance and compressive strength (EN ISO 604).

General information

Color

Gold

Guidance for specification option:

Brass.

Material

Resin

Guidance for specification option:

Thermoset.

Shape

Rectangle

Uniclass

Pr_35_90_15_89 Thermal break connection platesPrimary

CAWS

E40/448 Thermal break connection plates

E40/448 Thermal break connection plates

Specification data - Thermal break connection plates

Certification

Manufacturer's standard.

Guidance for specification option:

Test reports available for compression and to EN 1602, EN 12087 and EN 12664.

Material

Thermoset resin.

Dimensions

-

Length

Guidance for specification option:

Insert requirements.

Width

Guidance for specification option:

Insert requirements.

Thickness (maximum)

5 mm.

Guidance for specification option:

Tolerance: ±0.5 mm.

Thickness (minimum)

5 mm.

Guidance for specification option:

Tolerance: ±0.5 mm.

Compressive stress (maximum)

To EN ISO 604, 700 MPa.

Operating temperature (maximum)

Manufacturer's standard.

Operating temperature (minimum)

Manufacturer's standard.

Holes

Guidance for specification option:

Insert requirements (number and sizes).

Elastic modulus

To EN ISO 604, 5819 MPa.

Thermal Conductivity:

To DIN 52 612: 0.2082 W/m·K.

Fire rating

To EN 13501-1, A2.

Density

To ISO 1183, 2085 kg/m³.

Body colour

Brass.

Literature

Ecopad Data Sheet

Ecopad Data Sheet