Daikin Altherma High Capacity H HT Heat Pump EPRA-DW1/V3 (Sizes 14-16-18) - Heating system

Verified by manufacturer 3 months ago

ETBH16E6V + EPRA14DV3

Daikin Ltd Variant:
Third party certifications:
  • Quiet Mark Certification

    Quiet Mark Certification

    Certificate type

Quiet Mark certified high capacity, high temperature air-to-water heat pump.

Jump to:
+44 (0)845 641 9000 Website

Application

Suitable for use in domestic applications, specifically designed for the renovation market.

Description

A high temperature air-to-water heat pump for heating, cooling and domestic hot water. It has been designed for lower acoustic levels to meet the needs of urban areas and homeowner expectations.


Features both an indoor and outdoor unit.


Features and benefits:

  • R-32 Bluevolution technology reduces environmental impact due to its high energy efficiency and low refrigerant charge.
  • Leaving water temperature of 70C down to -15C outdoor.
  • All hydraulic components accessible from the top.
  • Designed to withstand the coldest climate conditions (to -28°C).
  • Outdoor unit has a sleek design, making it an aesthetically pleasing solution.
  • Available with an integrated water tank.
  • Wall mounted or floor standing indoor options.
  • Suitable for boiler replacement.
  • Easy and quick installation.
  • Pre-fitted with the cloud and app control functionality.
  • Quiet Mark certified, operating at quiet levels for maximum acoustic comfort.


For full technical information, consult manufacturer's literature.


Components:

  • EPRA014-018DV - Single fan outdoor unit. Extracts heat from the outdoor air, down to -28°C.
  • ETBH16E6V/9W - Indoor wall mounted heating only air to water heat pump.
  • ETBX16E6V/9W - Indoor wall mounted reversible heating and cooling air to water heat pump.
  • ETVH16S18E6V and ETVH16S23E6V - Indoor floor standing heating only unit including an 180 L or 230 L domestic hot water tank.

General information

Color

Silver

Black

White

Manufacturer guidance

  • Silver/ black casing (EPRA14-18DV3).
  • White and black casing (ETBH16E6V/9W and ETBX16E6V/9W, ETVH16S18E6V and ETVH16S23E6V).

Material

Steel

Guidance for specification option:

Polyester painted galvanised steel plate (EPRA14-16DV3).

Resin

Guidance for specification option:

Resin sheet material (ETBH16E6V, ETBH16E9W, ETBX16E6V, ETBX16E9W).

Shape

Rectangle

Length

-

Manufacturer guidance

Dependent on unit specified, see specification data for details.

Width

-

Manufacturer guidance

Dependent on unit specified, see specification data for details.

Height

-

Manufacturer guidance

Dependent on unit specified, see specification data for details.

Uniclass

Pr_70_60_37_04 Air-to-water heat pumpsPrimary

CAWS

T90/505 Air-to-water heat pumps

T90/505 Air-to-water heat pumps

Specification data - Air-to-water heat pumps

Standards

-

Test requirements

To BS EN 14511.

Heat pump type

Split.

Mode

Heating.

Coefficient of performance (minimum)

4.67 kW.

Guidance for specification option:

Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C).

Output

-

Heating

5.69 kW (nominal).

Guidance for specification option:

Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C).

Fan

-

Type

Propeller.

Fan drive

Direct.

Configuration

Horizontal.

Electrical supply type

Single phase.

Guidance for specification option:

230 V/ 50 Hz.

Compressor

-

Type

Scroll.

Sealing

Hermetically sealed.

Drive

Inverter driven.

Refrigerant

R32.

Guidance for specification option:

  • GWP: 675.0.
  • Charge: 4.20 kg.
  • Control: Expansion valve.
  • Refrigerant oil type: FW68DE.

Unit dimensions

1003 x 1270 x 533 mm (EPRA14DV3); 840 x 440 x 390 mm (ETBH16E6V).

Manufacturer guidance

Height x width x depth.

Unit weight

146 kg (EPRA14DV3); 38 kg (ETBH16E6V).

HeatingWaterFlowRate

16.3 L/min.

Guidance for specification option:

Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C).

Manufacturer guidance

Water side heat exchanger water flow rate.

Sound

To EN14825, 54.0 dB(A) (outdoor); 44.0 dB(A) (indoor).

Manufacturer guidance

Sound power level.

Air flow

3918 m³/h.

Manufacturer guidance

Air to water unit rated airflow (outdoor).

Integral accessories

Integrated back up heater, 6 kW (2 step).

Sustainability data

Contains Red List materials

No

Country of material origin

Europe

Country of product manufacture

Europe

Third party certifications

Quiet Mark Certification

Quiet Mark Certification

Daikin ASHP Quiet Mark Certificate

Similar products from Daikin Ltd

Daikin Altherma High Capacity R32 Monobloc EB/DLA-D3V3/W1 (Sizes 9-11-14-16) - Heating system

Daikin Altherma High Capacity R32 Monobloc EB/DLA-D3V3/W1 (Sizes 9-11-14-16) - Heating system

Daikin Altherma Low Capacity H HT Heat Pump EPRA-DW1/V3 (Sizes 8-10-12) - Heating system

Daikin Altherma Low Capacity H HT Heat Pump EPRA-DW1/V3 (Sizes 8-10-12) - Heating system

Daikin Altherma Low Capacity R32 Monobloc EB/DLA-EV3 (Sizes 4-6-8) - Heat pump

Daikin Altherma Low Capacity R32 Monobloc EB/DLA-EV3 (Sizes 4-6-8) - Heat pump

Low Temperature High Capacity R-Split Heat Pump (Size 11-14-16) - Water heater

Low Temperature High Capacity R-Split Heat Pump (Size 11-14-16) - Water heater

Low Temperature Low Capacity R-Split Heat Pump (Size 4-6-8) - Heating system

Low Temperature Low Capacity R-Split Heat Pump (Size 4-6-8) - Heating system