NBS Source
I'm a manufacturer
Compare variants

Custom Bespoke Profile Wall Systems - AP-CBP Range - Custom Profile Cladding System

Verified by manufacturer 3 months ago

System 10 - Oxford range, aluminium sheets - vertical

Architectural Profiles Ltd Variant:
Third party certifications:
  • CWCT Certificate

    CWCT Certificate

    Certificate type

Vertically or horizontally laid custom bespoke profiled wall cladding system.

Jump to:
+44 (0)118 927 2424 Website

Application

Wall cladding profiles.

Applications include: Educational and leisure facilities, commercial premises, offices and manufacturing facilities.

Description

Vertically or horizontally laid custom profile wall cladding system.


Features and benefits:

  • All system components are non-combustible.
  • Shape, size, pitch and depth of the profiles can be changed.
  • Oxford 'Multi F' Range (System 10)
  • Castellated Bank Range (System 20)
  • Castellated Newton Range (System 30)
  • ZigZag Pyramid Range (System 40)
  • Marlow Fin Range (System 50)
  • Blue TRP Range (System 60)
  • Waveform WFM Range (System 70)
  • Solid or perforated (Airwall™) profiles with choice of solid of perforated liner panels.
  • Available in aluminium, steel or Cor-Ten in a range of finishes:
  • Aluminium: PPC, Armacoil™ HDP, anodized, Stucco-Embossed Mill-Finish (SEMF) and Smooth Mill Finish (MF).
  • Steel: APL PUF, PPC or PRISMA.
  • Cor-Ten: Unweathered.
  • Successfully tested to CWCT-standards.
  • Available as a fire-resistance rated insulated system assembly when combined with APL Tritherm™ Spacer System, with simple system upgrades for improved fire resistance performance.
  • Available in discreet face fix (DFF) or secret fix (SF).
  • Available with coating warranties up to 40 years including in marine environments.
  • Available as Airwall™ - perforated.
  • System constructions available onto APL StrongBak™, cladding rails, SFS and blockwork.
  • 35 years’ experience of these specialized profiles
  • Available as acoustic construction with enhanced acoustic performance.


System components:

  • Liner sheet (if onto cladding rails).
  • APL StrongBak™ (specified separately).
  • Subframe (dependent on substrate).
  • Profile and flashings.

General information

Color

Silver

Guidance for specification option:

Aluminium or steel.

Other

Guidance for specification option:

Standard and RAL colours available.

Manufacturer guidance

Aluminium / Steel: Standard RAL Range; Contact APL for full details; Bespoke upon request

Cor-Ten: Unweathered.

Finish

Powder-coated

Guidance for specification option:

Class 1 or Class 2

Full RAL colour range and / or contact

APL for additional finishes such as anodised-look

Anodized

Guidance for specification option:

Contact APL for details

Natural

Guidance for specification option:

Smooth mill-finish aluminium

Unweathered Cor-Ten

Embossed

Guidance for specification option:

Stucco-embossed mill-finish aluminium or Armacoil™ HDP (Subject to minimum quantity)

Painted

Guidance for specification option:

Aluminium with Armacoil™ HDP (Subject to minimum quantity)

Steel with APL PUF or PRISMA

Manufacturer guidance

PPC, Armacoil™ HDP, Anodised, APL PUF, Stucco-Embossed Mill-Finish (SEMF), Smooth Mill Finish (MF). PRISMA

Material

Aluminium

Guidance for specification option:

Solid and perforated.

Steel

Cor-Ten

Guidance for specification option:

Solid and perforated.

Shape

Other

Guidance for specification option:

Bespoke profiles.

Length

Bespoke

Width

Bespoke

Guidance for specification option:

Refer to profile drawing

Manufacturer guidance

Refer to profile drawing

Height

Bespoke

Warranty description

25 year

Guidance for specification option:

Up to 25 years subject to location.

Cladshield™ fully-installed system warranty available; consult manufacturer for details.

Uniclass

Ss_25_20_68_50 Metal profiled sheet self-supporting cladding systemsPrimary

CAWS

H92/120 Rainscreen cladding

H31/10 Metal

H31/120 Metal

Specification data - Metal profiled sheet self-supporting cladding systems

System performance

-

Manufacturer guidance

Insert requirements.

Liner sheets

-

Material

Not required.

Guidance for specification option:

SFS / blockwork / timber.

AP19 LPH profile in 0.4 mm steel in off-white 80F - solid.

Guidance for specification option:

Where onto cladding rails.

APL StrongBak™.

Guidance for specification option:

Long-span, non-combustible structural cladding system based upon Kassett construction principles.

To be specified separately.

Primary fasteners

Guidance for specification option:

Consult manufacturer for details and insert requirements.

End and side laps

Side laps: Minimum 75 mm.

Guidance for specification option:

At 1 per mid span, APL P103 + P108/VCT sidelap sealant range, P152 Flute Fillers.

Air and vapour control layer

-

Material

AP19 LPH Liner sheet.

Guidance for specification option:

Cladding rails.

APL StrongBak™.

Guidance for specification option:

To be specified separately.

Other.

Guidance for specification option:

SFS/ blockwork substrate/ timber - refer to relevant manufacturer.

Fasteners

-

Manufacturer guidance

Consult manufacturer for details and insert requirements.

Sealing

-

Manufacturer guidance

Consult manufacturer for details and insert requirements.

Spacers

Tritherm Spacer System℗ - Fully-Filled Cavity.

Guidance for specification option:

  • Cladding rails: P665 RWB, P546 Isopad, P157 HH Bracket, P600 + P601 Horizontal Zed.
  • SFS/ blockwork/ timber: P618 Tophat, P665 RWB, P546 Isopad, P157 HH Bracket, P600 + P601 Zed.

Tritherm Spacer System℗ - Ventilated Cavity (CWCT-Tested).

Guidance for specification option:

SFS/ blockwork/ timber: P618 Tophat, P665-ALU RWB, P546 Isopad, P157-ALU HH Bracket, P754 + P785 ALU Zed.

Tritherm Spacer System℗ - Ventilated Cavity.

Guidance for specification option:

SFS/ blockwork/ timber: P521/4 + P528/4 HH brackets, P759 vertical ALU "L" rail, P754 ALU Zed.

Manufacturer guidance

Spacers are fixed with APL P191/HH range.

For U-value information, please review attached literature items. Additional U-values available – consult manufacturer for details.

Acoustic insulation

A1-rated with thickness and performance specification as required to meet performance.

Guidance for specification option:

Contact manufacturer for details and insert details as required.

Thermal insulation

A1-rated.

Guidance for specification option:

Thickness as required to meet U-value requirement with minimum lambda of 0.040 for all calculation purposes:

  • Cladding rails: With maximum 33 kg/m³ type, use P211/ Insulation Pins with P534 Washer at three per m³, bonded to liner sheet with P663 adhesive.
  • SFS/ blockwork/ timber - With maximum 33 kg/m³ type, use P211/Insulation Pins with P534 at three per m² fixed to P618 Tophat.
  • Where Rainscreen-Type (e.g. Duoslab) is used, use P211/DS/SS/70 in centres and P211/DS/PL/7/25 at each board perimeter, fixed back with P191/HH fixing.


Refer to the relevant U-value table in the supporting literature.

External sheets

-

Material

Aluminium profiled sheet - solid.

Aluminium profiled sheet - Airwall™ (perforated).

Manufacturer guidance

Cover width specified separately below.

Primary fasteners

-

Manufacturer guidance

Consult manufacturer for details and insert requirements.

Secondary fixings

-

Manufacturer guidance

Consult manufacturer for details and insert requirements.

End and side laps

-

Manufacturer guidance

Refer to manufacturer for guidance and insert requirements.

Wall glazing

Required.

Guidance for specification option:

Consult manufacturer for options and insert requirements.

Not required.

System accessories

APL Fixings.

Guidance for specification option:

P191 & P192.

APL Sealants.

APL System Flashings.

Guidance for specification option:

Including GE/F1 & GEX/F2 at system joints.

Clamp-End Lap.

Guidance for specification option:

Use P151 angle fixed to P600 with P109/GGB sealant at overlap to stop-scratching.

P152 Profile Flute Fillers.

Guidance for specification option:

As per APL recommendations and to match profiles.

Colour/ Finish

Armacoil™ HDP.

Guidance for specification option:

Subject to minimum quantities. Insert colour required.

Anodized.

Guidance for specification option:

Contact APL for details.

Polyester powder-coating, class 1.

Guidance for specification option:

Insert colour/ finish required.

Polyester powder-coating, class 2.

Guidance for specification option:

Insert colour/ finish required.

Stucco-Embossed Mill-Finish (SEMF).

Show more

Manufacturer guidance

Insert colour requirements.

Orientation

Vertical.

Minimum bearing area

50 mm.

NominalThickness

-

Manufacturer guidance

Contact APL for details and insert requirements.

Liner Supports

Guidance for specification option:

Subject to loadings.

Centres are to general areas only, closer at high load zones.


  • Cladding Rails - Maximum 1800 mm centres in general areas, closer at high load zones/ corners.
  • SFS - Refer to SFS manufacturer.
  • StrongBak - refer to separate specification.


Profile

AP26/BP-VTR/DFF/75-450.

Guidance for specification option:

Consult manufacturer's literature for profile details.

AP80/BP-VTR/DFF/200-800.

Recycled content (minimum)

Up to 95%.

Profile supports

-

Manufacturer guidance

Subject to loadings. Centres are to general areas only, closer at high load zones.


  • Onto Cladding Rails: 1) P665/P157 brackets at maximum 1200 mm centres horizontally and at cladding rail centres vertically; 2) Horizontal P600s fixed to every bracket.
  • Onto SFS with full-filled cavity: 1) Horizontal P618 top hats at max 1200 mm centres; 2) P665/P157 brackets at max 1200 mm centres horizontally and every top hat vertically; 3) Horizontal P600s fixed to every bracket.
  • Onto SFS with ventilated cavity: Contact APL.
  • Onto StrongBak: Refer to separate specification/ contact APL.

Sustainability data

Contains Red List materials

No

Country of product manufacture

United Kingdom

Recyclability

High

Recycled content

As defined in clause 7.8 of BS EN ISO 14021

%

Guidance for specification option:

Subject to substrate (steel or aluminium) and grade of aluminium

Third party certifications

CWCT Certificate

CWCT Certificate

CWCT Test - Bespoke, SlimwallFF, 45HR & 18HR

Literature

APL Liner Profiles - Roofing & Cladding - Data Sheet

APL Liner Profiles - Roofing & Cladding - Data Sheet

APL Liner Profiles - Roofing & Cladding - System Summary

APL Liner Profiles - Roofing & Cladding - System Summary

APL Airwall™ - System Summary

APL Airwall™ - System Summary

APL StrongBak™ - Cladding - System Brochure

APL StrongBak™ - Cladding - System Brochure

U-Values + Build Up - WALLS - Horizontal Orientation to Cladding Rails

U-Values + Build Up - WALLS - Horizontal Orientation to Cladding Rails

U-Values + Build Up - WALLS - Horizontal Orientation to  SFS / Blockwork

U-Values + Build Up - WALLS - Horizontal Orientation to SFS / Blockwork

U-Values + Build Up - WALLS - Vertical Orientation to Cladding Rails

U-Values + Build Up - WALLS - Vertical Orientation to Cladding Rails

U-Values + Build Up - WALLS - Vertical Orientation to  SFS / Blockwork

U-Values + Build Up - WALLS - Vertical Orientation to SFS / Blockwork

APL Armacoil™HDP + HDP-HT - Product Brochure

APL Armacoil™HDP + HDP-HT - Product Brochure

APL Custom Bespoke Profiles

APL Custom Bespoke Profiles

APL Cladding - Custom Bespoke Profiles - System Summary

APL Cladding - Custom Bespoke Profiles - System Summary

APL Cladding Systems Brochure

APL Cladding Systems Brochure

APL StrongBak™ - System Summary

APL StrongBak™ - System Summary

APL AluE™ Tritherm™ Aluminium  Spacer System - Cladding - System Summary

APL AluE™ Tritherm™ Aluminium Spacer System - Cladding - System Summary

Case studies

APL Case Study - Aluminium Sinusoidal Roofing & Perforated Cladding - Birmingham Energy Innovation Centre

APL Case Study - Aluminium Sinusoidal Roofing & Perforated Cladding - Birmingham Energy Innovation Centre

APL Case Study - APL Bespoke Cladding Profile - Greenlaw Business Centre

APL Case Study - APL Bespoke Cladding Profile - Greenlaw Business Centre

APL Case Study - Custom Bespoke Cladding Profile - Woodstock Road

APL Case Study - Custom Bespoke Cladding Profile - Woodstock Road

APL Case Study - Custom Bespoke Cladding Profile - Middlebeck School

APL Case Study - Custom Bespoke Cladding Profile - Middlebeck School