NBS Source
I'm a manufacturer
Compare variants

CS Allway® DGTP and GTP Series Floor Joint Covers - Dual Gasket

Verified by manufacturer 11 months ago

Allway® DGTP-200 floor-to-floor covers

Construction Specialties (UK) Ltd Variant:

Recess-mounted, dual-gasket flush floor covers designed for applications with large movement requirements.

Jump to:
+44 (0)1296 652800 Website

Application

Floor joint applications with large movement requirements in areas where flush finish and ease of cleaning are important.

Description

Recess-mounted, dual-gasket flush floor covers designed for applications with large movement requirements.

Deeper models can be installed over varying joint widths. Shallower models require a consistent joint width.


Features and benefits:

  • Joint width: up to 110 mm.
  • Horizontal movement: up to +38 mm.
  • Vertical movement: up to ±15 mm.
  • Lateral movement: up to ±8 mm.
  • Load capability: 250 kg point load.
  • Easy to clean, suited to interiors where hygiene is important.
  • Suitable for areas where light wheeled equipment is in use.
  • Fixing:
  • Floor fixings (by others) to suit substrate at 450 mm centres and to achieve minimum 40 mm embedment.
  • Wall fixings (by others) to suit substrate at 450 mm centres.

General information

Color

Silver

Black

Grey

White

Beige

Finish

Anodized

Guidance for specification option:

Centre plate and wall frames.

Mill

Guidance for specification option:

Floor side frames.

Material

Aluminium

Uniclass

Pr_35_90_53_86 Strip movement jointsPrimary

CAWS

E40/545 Compressible sealing strip system

E40/545 Compressible sealing strip system

Product range

CS Allway Gasketed Expansion Joint Covers for Floors

Specification data - Strip movement joints

Joint width

35–58 mm.

Edging

-

Material

Aluminium.

Finish

Natural anodized centre plate.
Other aluminium components are mill finished.

Colour

Silver.

Insert

-

Material

Co-extruded Thermoplastic Rubber (TPR) gasket.

Colour

Black.

Grey.

Greige.

White.

FrameDepth

30 mm.

Barriers

Not required.

Fire barrier.

Guidance for specification option:

Consult manufacturer for details and sizes, and insert requirements.

Acoustic barrier.

Guidance for specification option:

Consult manufacturer for details and sizes, and insert requirements.

Moisture barrier.

Guidance for specification option:

Consult manufacturer for details and sizes, and insert requirements.

Movement

Horizontal: ±20 mm; vertical: ±8 mm; lateral: ±6 mm.

Dimensions of recess (w x h)

Minimum recess width/ depth required: 175/ 35 mm.

Dimensions (visible width)

165 mm.

Manufacturer guidance

Exposed surface.

Literature

CS Allway Expansion Joint Covers (2023)

CS Allway Expansion Joint Covers (2023)