NBS Source
I'm a manufacturer

Compare variants

CS Allway® DGTP and GTP Series Floor Joint Covers - Dual Gasket
CS Allway® DGTP and GTP Series Floor Joint Covers - Dual Gasket
CS Allway® DGTP and GTP Series Floor Joint Covers - Dual Gasket

Verified 2 months ago

Construction Specialties (UK) Ltd

Verified 2 months ago

Construction Specialties (UK) Ltd

Verified 2 months ago

Construction Specialties (UK) Ltd
Summary
Recess-mounted, dual-gasket flush floor joint covers designed for applications with large movement requirements.
-
-
Application

Floor joint applications with large movement requirements in areas where flush finish and ease of cleaning are important.

-
-
Description

Recess-mounted, dual-gasket flush floor joint covers designed for applications with large movement requirements.

Deeper models can be installed over varying joint widths. Shallower models require a consistent joint width.

Features and benefits:

  • Joint width: up to 110 mm.
  • Horizontal movement: up to +38 mm.
  • Vertical movement: up to ±15 mm.
  • Lateral movement: up to ±8 mm.
  • Load capability: 250 kg point load.
  • Easy to clean, suited to interiors where hygiene is important.
  • Suitable for areas where light wheeled equipment is in use.
  • Fixing:
    • Floor fixings (by others) to suit substrate at 450 mm centres and to achieve minimum 40 mm embedment.
    • Wall fixings (by others) to suit substrate at 450 mm centres.
-
-
Color
Silver, Black, Grey, White, Beige
-
-
Finish
Anodized, Mill
-
-
Material
Aluminium
-
-
Warranty description
Two year
-
-

Specification

Joint width
35–58 mm.
-
-
Edging
-
-
-
Material
Aluminium.
-
-
Finish
Natural anodized centre plate. Other aluminium components are mill finished.
-
-
Colour
Silver.
-
-
Insert
-
-
-
Material
Co-extruded Thermoplastic Rubber (TPR) gasket.
-
-
Colour
Black., Grey., Greige., White.
-
-

Additional properties

FrameDepth
30 mm.
-
-
Barriers
Not required., Fire barrier., Acoustic barrier., Moisture barrier.
-
-
Movement
Horizontal: ±20 mm; vertical: ±8 mm; lateral: ±6 mm.
-
-
Dimensions of recess (w x h)
Minimum recess width/ depth required: 175/ 35 mm.
-
-
Dimensions (visible width)
165 mm.
-
-

Sustainability data

Material
Aluminium
-
-