Vertically or horizontally laid sinusoidal wall cladding system.

Jump to:
+44 (0)118 927 2424 Website

Application

Wall cladding profiles.

Applications include: Educational and leisure facilities, commercial premises, offices and manufacturing facilities.

Description

Vertically or horizontally laid sinusoidal wall cladding system.


Features and benefits:

  • All system components are non-combustible.
  • Matching roof system available (specified separately).
  • Available in aluminium, steel or Cor-Ten in a range of finishes:
  • Aluminium: PPC, Armacoil™ HDP, anodized, Stucco-Embossed Mill-Finish (SEMF) and Smooth Mill Finish (MF).
  • Steel: APL PUF, PRISMA, PPC, LeatherGrain (LG) Plastisol and plain galvanized finishes.
  • Cor-Ten: Unweathered.
  • Available as a fire-resistance rated insulated system assembly when combined with APL Tritherm™ Spacer System, with simple system upgrades for improved fire resistance performance.
  • Successfully tested to CWCT-standards as both a ventilated rainscreen cavity and a fully-filled cavity.
  • A1 fire-rated coatings available.
  • Available with coating warranties up to 40 years including in marine environments.
  • Available as Airwall - perforated.
  • System constructions available onto APL StrongBak™, cladding rails, SFS and blockwork.
  • 35 years’ experience of these specialized profiles.
  • Also available as a wider profile (45HR; specified separately)
  • Available as acoustic construction with enhanced acoustic performance.


System components:

  • Liner sheet (if onto cladding rails).
  • APL StrongBak™ (specified separately).
  • Subframe (dependent on substrate).
  • Profile and flashings.

General information

Color

Silver

Guidance for specification option:

Aluminium

Other

Guidance for specification option:

Standard RAL Range; Contact APL for full details; Bespoke upon request

Manufacturer guidance

Aluminium / Steel: Standard RAL Range; Contact APL for full details; Bespoke upon request

Cor-Ten: Unweathered.

Finish

Powder-coated

Guidance for specification option:

Class 1 or Class 2

Full RAL colour range and / or contact

APL for additional finishes such as anodised-look

Anodized

Guidance for specification option:

Contact APL for details

Natural

Guidance for specification option:

Smooth mill-finish aluminium

Embossed

Guidance for specification option:

Stucco-embossed mill-finish aluminium or Armacoil™ HDP (Subject to minimum quantity)

Painted

Guidance for specification option:

Aluminium with Armacoil™ HDP (Subject to minimum quantity)

Steel with APL PUF, PRISMA or Leathergrain Plastisol

Manufacturer guidance

PPC, Armacoil™ HDP, Anodised, APL PUF, Stucco-Embossed Mill-Finish (SEMF), Smooth Mill Finish (MF). PRISMA, Leathergrain Plastisol

Material

Aluminium

Guidance for specification option:

Solid and perforated.

Steel

Cor-Ten

Guidance for specification option:

Solid and perforated.

Shape

Other

Guidance for specification option:

Sinusoidal, corrugated

Manufacturer guidance

Sinusoidal, corrugated

Length

Bespoke

Width

990 mm

Guidance for specification option:

Cover width.

Height

19 mm

Warranty description

25 year

Guidance for specification option:

Up to 25 years subject to location.

Cladshield™ fully-installed system warranty available; consult manufacturer for details.

Uniclass

Ss_25_20_68_50 Metal profiled sheet self-supporting cladding systemsPrimary
Ss_25_20_70_25 Drained and back-ventilated rainscreen cladding systems

CAWS

H92/120 Rainscreen cladding

H31/10 Metal

H31/120 Metal

Specification data - Metal profiled sheet self-supporting cladding systems

System performance

-

Manufacturer guidance

Insert requirements.

Liner sheets

-

Material

Not required.

Guidance for specification option:

SFS / blockwork / timber.

AP19 LPH profile in 0.4 mm steel in off-white 80F - solid.

Guidance for specification option:

Where onto cladding rails.

APL StrongBak™.

Guidance for specification option:

Long-span, non-combustible structural cladding system based upon Kassett construction principles.

To be specified separately.

Primary fasteners

APL P191/HH fixing range.

Guidance for specification option:

Manufacturer's standard, consult manufacturer for details.

End and side laps

Minimum 75 mm; APL P191/HH fixing range.

Guidance for specification option:

At 1 per mid span, APL P103 + P108/VCT sidelap sealant range, P152 Flute Fillers.

Air and vapour control layer

-

Material

AP19 LPH Liner sheet.

Guidance for specification option:

Cladding rails.

APL StrongBak™.

Guidance for specification option:

To be specified separately.

Other.

Guidance for specification option:

SFS/Blockwork substrate/Timber - refer to relevant manufacturer.

Fasteners

APL P191/HH fixing range.

Guidance for specification option:

Cladding rails.

Other.

Guidance for specification option:

SFS/ blockwork/ timber - refer to relevant manufacturer.

Sealing

APL P191/HH fixing range (side laps sealed with 2x runs of P108/VCT).

Guidance for specification option:

Cladding rails.

Other.

Guidance for specification option:

SFS/ blockwork/ timber - refer to relevant manufacturer.

Spacers

Tritherm Spacer System℗ - Fully-Filled Cavity.

Guidance for specification option:

  • Cladding rails: P665 RWB, P546 Isopad, P157 HH Bracket, P600 + P601 Horizontal Zed.
  • SFS/ blockwork/ timber: P618 Tophat, P665 RWB, P546 Isopad, P157 HH Bracket, P600 + P601 Zed.

Tritherm Spacer System℗ - Ventilated Cavity (CWCT-Tested).

Guidance for specification option:

SFS/ blockwork/ timber: P618 Tophat, P665-ALU RWB, P546 Isopad, P157-ALU HH Bracket, P754 + P785 ALU Zed.

Tritherm Spacer System℗ - Ventilated Cavity.

Guidance for specification option:

SFS/ blockwork/ timber: P521/4 + P528/4 HH brackets, P759 vertical ALU "L" rail, P754 ALU Zed.

Manufacturer guidance

Spacers are fixed with APL P191/HH range.

For U-value information, please review attached literature items. Additional U-values available – consult manufacturer for details.

Acoustic insulation

A1-rated with thickness and performance specification as required to meet performance.

Guidance for specification option:

Contact manufacturer for details and insert details as required.

Thermal insulation

A1-rated.

Guidance for specification option:

Thickness as required to meet U-value requirement with minimum lambda of 0.040 for all calculation purposes:

  • Cladding rails: With maximum 33 kg/m³ type, use P211/ Insulation Pins with P534 Washer at 3no per m³, bonded to liner sheet with P663 adhesive.
  • SFS/ blockwork/ timber - With maximum 33 kg/m³ type, use P211/Insulation Pins with P534 at 3 no per m² fixed to P618 Tophat.
  • Where Rainscreen-Type (e.g. Duoslab) is used, use P211/DS/SS/70 in centres and P211/DS/PL/7/25 at each board perimeter, fixed back with P191/HH fixing.


Refer to the relevant U-value table in the supporting literature.

External sheets

-

Material

18HR aluminium profiled sheets - solid.
18HR aluminium profiled sheets - Airwall™ (perforated).

Manufacturer guidance

Cover width: 990 mm.

Profile width: 76.2 mm.

Primary fasteners

APL 191/LP fixing range; valley fix at every corrugation at end laps and every other corrugation elsewhere - colour matched as required.

Secondary fixings

APL 191/LP fixing range - colour matched as required.

End and side laps

End laps: 125 mm; APL 191/LP fixing range - colour matched as required.

Guidance for specification option:

Side laps stitched at maximum 400 mm centres; APL P109/GGB sealant 6 mm diameter for side laps and end laps; APL P152/HP Flute Fillers; GE/F1 flashing at system joints; GEX/F2 flashing at corners.

Wall glazing

Required.

Guidance for specification option:

Consult manufacturer for options and insert requirements.

Not required.

System accessories

APL Fixings.

Guidance for specification option:

P191 & P192.

APL Sealants.
APL System Flashings.

Guidance for specification option:

Including GE/F1 & GEX/F2 at system joints.

Clamp-End Lap.

Guidance for specification option:

Use P151 angle fixed to P600 with P109/GGB sealant at overlap to stop-scratching.

P152 Profile Flute Fillers.

Guidance for specification option:

As per APL recommendations and to match profiles.

Colour/ Finish

Armacoil™ HDP.

Guidance for specification option:

Subject to minimum quantities. Insert colour required.

Anodized.

Guidance for specification option:

Contact APL for details.


Polyester powder-coating, class 1.

Guidance for specification option:

Insert colour/ finish required.


Polyester powder-coating, class 2.

Guidance for specification option:

Insert colour/ finish required.


Stucco-Embossed Mill-Finish (SEMF).

Show more

Manufacturer guidance

Insert colour requirements.

Orientation

Vertical.

Minimum bearing area

50 mm.

NominalThickness

0.9 mm.

Liner Supports

Guidance for specification option:

Subject to loadings.

Centres are to general areas only, closer at high load zones.


  • Cladding Rails - Maximum 1800 mm centres in general areas, closer at high load zones/ corners.
  • SFS - Refer to SFS manufacturer.
  • StrongBak - refer to separate specification.


Profile supports

-

Manufacturer guidance

Subject to loadings. Centres are to general areas only, closer at high load zones.

 

  • Onto Cladding Rails: 1) P665/P157 brackets at maximum 1200 mm centres horizontally and at cladding rail centres vertically; 2) Horizontal P600s fixed to every bracket.
  • Onto SFS with full-filled cavity: 1) Horizontal P618 top hats at max 1200 mm centres; 2) P665/P157 brackets at max 1200 mm centres horizontally and every top hat vertically; 3) Horizontal P600s fixed to every bracket.
  • Onto SFS with ventilated cavity: Contact APL.
  • Onto StrongBak: Refer to separate specification/ contact APL.


Recycled content (minimum)

Up to 95%.

Sustainability data

Contains Red List materials

No

Country of product manufacture

United Kingdom

Recyclability

High

Recycled content

As defined in clause 7.8 of BS EN ISO 14021

Guidance for specification option:

Subject to substrate (steel or aluminium) and grade of aluminium

Third party certifications

CWCT Certificate

CWCT Certificate

CWCT Test - Bespoke, SlimwallFF, 45HR & 18HR

Literature

AP18HR - Steel - Cladding Data Sheet

AP18HR - Steel - Cladding Data Sheet

AP18HR - Aluminium - Cladding Data Sheet

AP18HR - Aluminium - Cladding Data Sheet

APL Liner Profiles - Roofing & Cladding - Data Sheet

APL Liner Profiles - Roofing & Cladding - Data Sheet

APL Liner Profiles - Roofing & Cladding - System Summary

APL Liner Profiles - Roofing & Cladding - System Summary

APL Tritherm Spacer System℗ - Aluminium - Data Sheet

APL Tritherm Spacer System℗ - Aluminium - Data Sheet

APL Tritherm Steel Spacer System - Cladding - System Summary

APL Tritherm Steel Spacer System - Cladding - System Summary

APL Tritherm Spacer System℗ - STEEL - Data Sheet

APL Tritherm Spacer System℗ - STEEL - Data Sheet

U-Values + Build Up - WALLS - Horizontal Orientation to Cladding Rails

U-Values + Build Up - WALLS - Horizontal Orientation to Cladding Rails

U-Values + Build Up - WALLS - Horizontal Orientation to  SFS / Blockwork

U-Values + Build Up - WALLS - Horizontal Orientation to SFS / Blockwork

U-Values + Build Up - WALLS - Vertical Orientation to Cladding Rails

U-Values + Build Up - WALLS - Vertical Orientation to Cladding Rails

U-Values + Build Up - WALLS - Vertical Orientation to  SFS / Blockwork

U-Values + Build Up - WALLS - Vertical Orientation to SFS / Blockwork

APL Airwall™ - System Summary

APL Airwall™ - System Summary

APL Armacoil™HDP + HDP-HT - Product Brochure

APL Armacoil™HDP + HDP-HT - Product Brochure

APL StrongBak™ - Cladding - System Brochure

APL StrongBak™ - Cladding - System Brochure

APL Cladding - Sinusoidal Profiles - System Summary

APL Cladding - Sinusoidal Profiles - System Summary

APL Cladding Systems Brochure

APL Cladding Systems Brochure

APL StrongBak™ - System Summary

APL StrongBak™ - System Summary

APL AluE™ Tritherm™ Aluminium  Spacer System - Cladding - System Summary

APL AluE™ Tritherm™ Aluminium Spacer System - Cladding - System Summary

Case studies

APL Case Study - Aluminium AP50HR Half-Round & Sinusoidal Cladding - Leeds College of Building

APL Case Study - Aluminium AP50HR Half-Round & Sinusoidal Cladding - Leeds College of Building

APL Case Study - Aluminium Sinusoidal Roofing & Perforated Cladding - Birmingham Energy Innovation Centre

APL Case Study - Aluminium Sinusoidal Roofing & Perforated Cladding - Birmingham Energy Innovation Centre

APL Case Study - APL StrongBak™ & Sinusoidal Cladding - GTIMC, University of Sheffield

APL Case Study - APL StrongBak™ & Sinusoidal Cladding - GTIMC, University of Sheffield

APL Case Study - APL SnapLoc™ & Airwall™ Cladding - Broxbourne Business Centre

APL Case Study - APL SnapLoc™ & Airwall™ Cladding - Broxbourne Business Centre

Similar products from Architectural Profiles Ltd

Concave / Half-Round Profile Wall System - AP50-Curveline™  - Concave Profile Cladding System

Concave / Half-Round Profile Wall System - AP50-Curveline™ - Concave Profile Cladding System

Custom Bespoke Profile Wall Systems - AP-CBP Range - Custom Profile Cladding System

Custom Bespoke Profile Wall Systems - AP-CBP Range - Custom Profile Cladding System

Discreet Fix Flat Panel Rainscreen Cladding System - APL Slimwall™ CPS/SSF - Rainscreen Flat Panel Cladding System

Discreet Fix Flat Panel Rainscreen Cladding System - APL Slimwall™ CPS/SSF - Rainscreen Flat Panel Cladding System

Face-Fix Flat Panel Rainscreen Cladding System - APL Slimwall™ (FF) - Flat Panel Rainscreen Cladding System

Face-Fix Flat Panel Rainscreen Cladding System - APL Slimwall™ (FF) - Flat Panel Rainscreen Cladding System

Half-Round Profile Wall System - AP50HR - Half-round Profile Cladding System

Half-Round Profile Wall System - AP50HR - Half-round Profile Cladding System

Long-span Structural Wall Panel System - APL StrongBak™  - Non-Combustible

Long-span Structural Wall Panel System - APL StrongBak™ - Non-Combustible

Louvre Profile Wall Cladding System - AP70 LCP  - Louvre Profile Cladding System

Louvre Profile Wall Cladding System - AP70 LCP - Louvre Profile Cladding System

Louvre System - Live Louvres - APL LB3 & LB4 - Live Louvre System

Louvre System - Live Louvres - APL LB3 & LB4 - Live Louvre System

Secret-Fix Flat Plank & Panel Rainscreen Cladding System - APL Slimwall™ SFP - Secret-Fix Rainscreen Panel

Secret-Fix Flat Plank & Panel Rainscreen Cladding System - APL Slimwall™ SFP - Secret-Fix Rainscreen Panel

Sinusoidal / Half-Round (40mm Deep) Profile Wall System - AP45HR - Sinusoidal Profile Cladding System

Sinusoidal / Half-Round (40mm Deep) Profile Wall System - AP45HR - Sinusoidal Profile Cladding System