Verified by manufacturer 2 months ago
Warringtonfire
Certificate type
Concealed steel door frame and timber leaf for outward opening single swing doors in metal or timber stud internal walls.
Steel section door frame, reveal lining and edge bead for single & double riser doors in gypsum board faced, metal or timber stud internal walls.
Features and benefits:
Door leaf size (maximum):
Where leaf size is specified, tolerances will be added by manufacturer. Actual maximum varies with door weight and number of hinges; consult manufacturer for details.
- FD30 (w x h):
- FD60:
Installation:
Color | White Other |
Finish | Galvanized Powder-coated Veneered Laminated Primed |
Material | Timber Steel |
Shape | Rectangle |
Length | Bespoke |
Width | Bespoke |
Height | Bespoke |
Warranty description | Two year |
Uniclass | |
CAWS | L20/55 Doorsets L20/410 Wood doorsets |
Configuration | Double leaf, single action.Single leaf, single action.Leaf and part leaf, single action. |
Doorset size | Manufacturer guidanceInsert requirements.
Door leaf size (maximum): Where leaf size is specified, tolerances will be added by manufacturer. Actual maximum varies with door weight and number of hinges; consult manufacturer for details. |
Performance | |
Fire resistance | |
Integrity | Unrated.To BS 476-22, 30 minutes.To BS 476-22, 60 minutes.Guidance for specification option:
|
Insulation | Unrated.To BS 476-22, 30 minutes.To BS 476-22, 60 minutes.Guidance for specification option:
|
Acoustic performance | To BS EN ISO 10140-2, 29 dB.To BS EN ISO 10140-2, 32 dB. |
Frame | |
Material | Steel.Guidance for specification option: Steel conforms to ASTM A653. |
Threshold | Shadow gap.No threshold.Concealed frame threshold.Manufacturer guidanceConsult manufacturer for details. |
Finish | Galvanized.Guidance for specification option: For site painting, as standard. Powder coated.Guidance for specification option: Special order. Minimum quantity may apply. |
Colour | None.RAL.Guidance for specification option: For powder coating, insert requirement. |
Door leaf | |
Thickness | 44 mm.54 mm. |
Core | Solid core. |
Facings | Plastic.Laminate.Timber veneer.MDF board.Plywood.Chipboard.PVC.Non-metallic foils.Smooth RAL primed.Guidance for specification option: Insert requirements. Manufacturer guidanceConsult manufacturer for fire ratings. |
Lippings | Hardwood timber lippings. |
Perimeter seals | Acoustic seals to frame.Intumescent and smoke seals to perimeter. |
Finish | Primed ready for site finish.Timber veneer.Plastic.Laminate.PVC.Non-metallic foils.Timber.Paint grade timber.Pre-painted.Guidance for specification option: Insert requirements. |
Glazing | |
Type | Vision panel not required.Vision panel required.Guidance for specification option: Consult manufacturer for options and insert type and size. |
Hardware | As schedule.SH-45 three-way adjustable concealed hinge.Guidance for specification option: 45 kg per pair, satin chrome finish, door thickness 44 mm only. SH-80 three-way adjustable concealed hinge.Guidance for specification option: 80 kg per pair, satin chrome finish, door thickness 44 mm only. Visible butt hinge, 44 mm.Guidance for specification option: Stainless steel finish. Visible butt hinge, 54 mm.Guidance for specification option: Stainless steel finish. Door stop, Section C45 - For 44 mm leaf.Door stop, Section C56 - For 54 mm leaf.Manufacturer guidanceStandard flush hinges are surface mounted to frame. Purpose made. SH/ Tectus hinges are secured to back box on the frame with cut-outs provided, prior to frame installation. Hinge cutouts to doors are pre-prepared in the factory. Notch in timber substrate specific to each hinge. |
Skirting | Not required. Flush. Guidance for specification option: Insert size requirements. Surface-mounted. Guidance for specification option: Insert size requirements. |
FSC certified | Not required. Required. |
Strike plate | As schedule. Stainless steel - Standard, with plastic insert. |
Door lining | SC47 – door lining for 44 mm doors, NFR and FD30. Guidance for specification option: No RA section required. SC56 – door lining for 54 mm doors, FD60. Guidance for specification option: RA section required to achieve fire rating. |
Door frame | RA25 - 25 mm. Guidance for specification option: Suitable for wall thickness: 92–100 mm with 44 mm door, 98-111 mm with 54 mm door. RA35 - 35 mm. Guidance for specification option: Suitable for wall thickness: 100–111 mm with 44 mm door, 112-120 mm with 54 mm door. RA50 - 50 mm. Guidance for specification option: Suitable for wall thickness: 114–124 mm with 44 mm door, 122-135 with 54 mm door. RA60 - 60 mm. Guidance for specification option: Suitable for wall thickness: 127–136 mm with 44 mm door, 133-145 mm with 54 mm door. RA65 - 65 mm. Guidance for specification option: Suitable for wall thickness: 130–140 mm with 44 mm door, 137-150 mm with 54 mm door. |
Third-party certification | FD30 Global Assessment: Chilt/A08124 Revision D, FD60 Global Assessment: Chilt/A12150 Revision A. |
Country of material origin | United Kingdom |
Country of product manufacture | United Kingdom |
Material | Timber Steel |
NBS BIM Object Standard
This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.
Find out more about the NBS BIM Object Standard.
Platform | Compatible | Version |
---|---|---|
- | 1 | |
- | 1 |
Concealed Frame Timber Riser Doors | Una from Selo
Timber Riser Doors Operation & Maintenance | Una from Selo
Timer Riser Doors Installation Instructions NFR & FD30 | Una from Selo
Timber Riser Doors Installation Instructions FD60 | Una from Selo
Timber Riser Doors Wall construction preparation - Una from Selo