NBS Source
I'm a manufacturer

Bespoke Rooflights

Verified by manufacturer 16 days ago

The Rooflight Co.

Bespoke rooflights for pitched or flat roofs.

Jump to:
+44 (0)1993 833155 Website

Application

Suitable for any commercial or residential building with either a flat or pitched roof.

Description

Company designers have the technical expertise to create a unique rooflight, providing project specific drawings with installation details and offering support from start to finish.


Features and benefits:

  • Bespoke rooflights in virtually any size, shape or colour.
  • Access, egress or sound proofing options available.
  • Steel sections, with a protective, polyester powder coating or stainless steel.
  • Integral Thermoliner® PVC-U decoupled lining improves thermal performance and drains away any condensation.
  • Fast made to measure service for stretched, non-standard sizes.

General information

Color

Black

Guidance for specification option:

RAL9005.

Grey

Guidance for specification option:

Light Grey (BS00A09), Dark Grey (BS00A13).

White

Guidance for specification option:

RAL9010.

Other

Guidance for specification option:

As per manufacturer and includes BS, all standard RAL colours and other special colours to match roof covering available on request.

Finish

Powder-coated

Material

Glass

Steel

Shape

Other

Guidance for specification option:

Polysided or design solutions to suit specific size and shape requirements.

Rectangle

Square

Triangle

Length

Bespoke

Width

Bespoke

Height

Bespoke

Warranty description

Guidance for specification option:

Rooflights must be registered online to receive the full warranty.

One year

Guidance for specification option:

On ancillary items.

Five year

Guidance for specification option:

On glass.

Ten year

Guidance for specification option:

On frames upon the rooflights being registered for free, online via the manufacturer website.

Uniclass

Pr_30_59_72_31 Framed rooflightsPrimary

CAWS

L10/45 Rooflights

L10/460 Rooflights

Specification data - Framed rooflights

Form

Flat.

Pitched.

Size

As drawing.

Product performance

-

Whole window U-value

1.4 W/m²K.

Guidance for specification option:

Based on our standard specifications. Whole unit U-values will vary depending on specification and design. U-values as low as 1.0 W/m²K can be achieved.

Frame

-

Material

Carbon steel.

Stainless steel.

Guidance for specification option:

Different material specifications (e.g. stainless steel) are available for applications in industrial or maritime locations. Consult manufacturer for details.

Finish

-

Coating

Polyester powder coating.

Colour

Black (RAL 9005).

Dark Grey (BS 00A13).

Light Grey (BS 00A09).

White (RAL 9010).

Any BS.

Guidance for specification option:

Insert requirements.

Any RAL.

Guidance for specification option:

Insert requirements.

As drawing.

As schedule.

Glazing or infill

-

Type

Insulating glass units.

Construction

4 mm SGG Planilux Toughened Outer, 16 mm 90% Argon Cavity, 4 mm SGG Planitherm One II (Low E) Toughened Inner.

Guidance for specification option:

Achieving a glass centre pane U-value of 1.0 W/m²K.

Manufacturer guidance

Enhanced glazing specification incorporating thermal, acoustic, security, light transmission, passive solar gain and decorative options are available.

Colour

Clear.

Opal.

Bronze tint.

Grey tint.

Diffused.

Coating

Low emissivity.

Solar control.

UV protection.

Self-cleaning.

Integral kerb

Insulated kerb to be formed on site.

Operation

-

Type

Electric openings.

Electric chain actuator.

Electric linear actuator.

Electric rack actuator.

Hand winder.

Manual openings (within reach).

Manual openings (out of reach).

Pole winder and winding crank.

Control

Rain sensors.

Link to BMS

Remote control.

Switch control.

Accessories

Not required.

Rain temperature and smoke sensors.

Guidance for specification option:

Available on request.

An on/ off switch is required .

Guidance for specification option:

Consult manufacturer for details.

Electric actuators

Guidance for specification option:

  • Power requirements: dependent on application.
  • The selection of actuator depends on the rooflight size and application.

Manufacturer guidance

Rain, temperature and smoke sensors are available on request. An on/ off switch is required. Consult manufacturer for details and insert requirements.

Standard

To BS EN1279-2.

Third-party certification

BSI Kitemark and KM 93754.

Sustainability data

Material

Glass

Steel

Case studies

Tin House

Tin House

Similar products from The Rooflight Co.

neo Advance Skywalk®

neo Advance Skywalk®

Plateau Rooflight Added Security

Plateau Rooflight Added Security

Plateau Rooflight Secured By Design

Plateau Rooflight Secured By Design

The Conservation Lantern Rooflight

The Conservation Lantern Rooflight

The Conservation Pyramid Rooflight

The Conservation Pyramid Rooflight

The Plateau Rooflight

The Plateau Rooflight