NBS Source
I'm a manufacturer

Bauder Total Green Roof System Reinforced Bitumen Membrane Cold Roof Covering System Self-Adhered (with Torch-On Capping Sheet)

Verified by manufacturer over a year ago

Bauder Ltd Third party certifications:
  • EPD

    EPD

    Certificate type

  • BBA Agrément Certificate

    BBA Agrément Certificate

    Certificate type

  • CCPI System

    CCPI System

    Certificate type

Total bitumen green cold roof system, incorporating torch-on bitumen root resistant capping sheet with self-adhered bitumen underlayer.

Jump to:
+44 (0)1473 257671 Website

Application

Suitable for a variety of applications on both new build and refurbishment projects and can be used in warm, cold and inverted roof scenarios.

Description

Total bitumen green cold roof system, incorporating torch-on bitumen root resistant capping sheet with self-adhered bitumen underlayer.

Bauder Total Green Roof System (BTGRS) is suitable for a variety of applications on both new build and refurbishment projects and can be used in warm, cold and inverted roof scenarios.

See BBA certification 10/4744. BTGRS can meet current UK Building Regulations Part B for external fire protection.


Features and benefits:

  • Capping sheet with tensile strength up to 1000 N/50mm.
  • Withstands climatic extremes of over 100⁰C variation.
  • Patented self-adhesive DUO products. The "DUO" lap technology ensures thorough sealing of lap joints, even in lower temperatures.
  • Expandable graphite fire retardant reduces spread of flame.
  • Heavy duty, robust and extremely tough.
  • Service life in excess of 35 years as stated in BBA certificate 10/4744.
  • Resistant to European climatic conditions.
  • Membrane resists impact and tearing.
  • Can satisfy requirements of Part B of Building Regulations.

General information

Color

Green

Material

Bitumen

Shape

Square

Rectangle

Warranty description

-

Manufacturer guidance

A comprehensive range of guarantee options are available. Please contact your local Bauder Area Technical Manager for more information.

Uniclass

Ss_30_40_30_70 Reinforced bitumen membrane cold roof covering systemsPrimary

CAWS

J41/12 Reinforced bitumen membrane cold deck roof covering

J41/130 Built-up reinforced bitumen membrane cold deck roof covering

Product range

Built-Up Bituminous Systems

Specification data - Reinforced bitumen membrane cold roof covering systems

Preparation

-

Horizontal work

Activator-Primer (Canister) APR01 - Black.

Guidance for specification option:

Synthetic rubber resin-based primer, developed to provide the necessary preparation of substrates prior to the installation of self-adhesive and torch-applied membranes. The spray application offers improved film thickness speed of application (by up to 50% over roller applied products) and quick drying in a matter of minutes.

  • Coverage: Approx. 96 g/m² (300 mm-wide spray one coat, 192 g/m² two coats). Two coats may be required for very porous substrates.
  • Application temperature: +5 to +30°C.
  • Drying time (at 10°C): 5–10 minutes.
  • Colour: Black.
  • Recoat time if left exposed: Four hours.
  • Suitable substrates: Oriented strand board (OSB); plywood; timber; concrete; lightweight concrete or cementitious materials; metal; Bauder self-adhesive underlayers; existing asphalt and bitumen membranes; polyisocyanurate (PIR) insulation.
  • Non-suitable substrates: Mica finished surfaces (e.g. KSD FBS); Laminated paper-foil faced insulation; expanded polystyrene (EPS) or extruded polystyrene (XPS) insulations; BauderROCK or mineral wool insulation; BauderGLAS or cellular glass insulation; copper; thermoplastic waterproofing membranes.

Skirtings and vertical work

As 'Horizontal work'.

Waterproof covering

-

First layer

-

Type

BauderTEC KSA DUO.

Guidance for specification option:

A technically advanced self-adhesive SBS elastomeric bitumen underlayer with “DUO” lap technology to ensure thorough sealing of lap joints, even in lower temperatures. The product features a glass lattice reinforcement for strength and stability. The product benefits from cleaner, safer and faster installation than traditional torch-applied membranes.

  • Width: 1 m.
  • Length: 7.5 m.
  • Thickness: 3 mm.
  • Weight: 3.5 kg/m².
  • Surface: Top: Foil; Bottom: Peel off release film covering self-adhesive bitumen.
  • Reinforcement: 200 g/m² glass lattice.
  • Cold bending test: Top -25°C; Bottom -30°C.
  • Softening point: >100°C.
  • Tensile strength: Length >1000 N/50mm; transverse >1000 N/50mm.
  • Elongation at break: Length >2%; transverse >2%.

Attachment

Self-adhered.

Top layer

-

Type

PLANT E.

Guidance for specification option:

A high quality, heavy duty, torch-applied, elastomeric bitumen capping sheet. The product features chemically treated bitumen to deliver superior root resistance which has been tested and approved by the FLL. The membrane is reinforced with 250 g/m² spunbond polyester fleece to allow the finished product to cope with structural movement without fracture. Expandable graphite fire retardant is also incorporated to reduce spread of flame.

  • Width: 1 m.
  • Length: 5 m.
  • Thickness: 5.2 mm.
  • Weight: 6 kg/m².
  • Surface: Top: Green slate mineral chippings; Bottom: Thermofusible polyethylene.
  • Reinforcement: 250 g/m² recycled spunbond polyester.
  • Cold bending test: -36°C.
  • Softening point: >120°C.
  • Tensile strength: Length >1000 N/50mm; transverse >1000 N/50mm.
  • Elongation at break: Length >45%; transverse >45%.

Attachment

Torch applied.

Detail work

-

Flashings

Bauder GRP Trim.

Guidance for specification option:

GRP roof edge Trim for use with Bauder bituminous roof systems. Available colours of either grey or black and a choice of profiles to suit the requirements of most projects.

Bauder Aluminium Termination Bar.

Guidance for specification option:

Natural finish aluminium alternative to a lead counterflashing for use at upstand details to give protection to the top edge of the waterproofing. It should be restricted to use on upstands where a chase cannot be cut into the wall.

Bauder GRP Termination Bar.

Guidance for specification option:

Black glass reinforced plastic (GRP) alternative to a lead counterflashing for use at upstand details to give protection to the top edge of the waterproofing. It should be restricted to use on upstands where a chase cannot be cut into the wall.

Skirtings and upstands

Not required.

Bauder LiquiFIBRE Detailing Kit.

Guidance for specification option:

Fast curing waterproofing resin containing fibre reinforcement that can be used for detailing awkward shapes or inaccessible areas where using LiquiDETAIL is impractical. PMMA-based resin that requires a catalyst and is solvent, isocyanate and halogen free.

Bauder LiquiDETAIL.

Guidance for specification option:

Cold liquid applied fast curing waterproofing resin that can be used on upstands and details. PMMA-based resin that requires the addition of catalyst to trigger curing and is solvent, isocyanate and halogen free.

Welted drips

Required.

Guidance for specification option:

Insert requirements.

Not required.

Cover strips

Required.

Guidance for specification option:

Insert requirements.

Not required.

Ancillary items

Required.

Guidance for specification option:

Insert requirements.

Not required.

Surface protection

Not required.

Landscaping options.

Guidance for specification option:

Consult manufacturer for information.

System accessories

Not required.

Bauder lightning conductors.

Guidance for specification option:

Lightning conductor clips are a specially designed secure clip that allows for movement.

  • Bauder Lightning conductor – Type 4: Polyvinyl chloride (PVC) coated or bare conductor.

Bauder insulated rainwater outlets.

Guidance for specification option:

For maintaining thermal continuity at drainage points. Suitable for warm, cold and inverted roof construction, the high thermal value of the rigid foam body prevents condensation from forming on the underside of the outlet.

Designed for use when connecting to conventional drainage systems, with excellent flow rate performance and is suitable for both new build and refurbishment projects. Outlets are included in the Bauder waterproofing system guarantee as they are integrated components.

Flow rate figures (where applicable) are based on BS EN 12056:3:2000, typically taken using a 35 mm header of water including leaf grille:

  • Bauder Bitumen Compact Vertical Outlet DN100: Insulated internal outlet, 6.1 L/s.
  • Bauder Bitumen Vertical Outlet DN70: Insulated internal outlet, 7.1 L/s.
  • Bauder Bitumen Vertical Outlet DN150: Insulated internal outlet, 7.2 L/s.
  • Bauder Bitumen Warm Roof Refurb Outlet DN63: Insulated internal outlet, 6.1 L/s.
  • Bauder Bitumen Warm Roof Refurb Outlet DN90: Insulated internal outlet, 5.7 L/s.
  • Bauder Bitumen Refurb Outlet DN95 – Un-insulated straight drop outlet, designed to ensure the maximum flow rate of the existing downpipe is not exceeded.
  • Bauder Bitumen Refurb Outlet DN125 – Un-insulated straight drop outlet, designed to ensure the maximum flow rate of the existing downpipe is not exceeded.
  • Bauder Insulated Parapet Outlet DN100 including pre-assembled pipe and dome grate: 0.6 L/s connected to external pipework; 0.7 L/s connected to external hopper.
  • Bauder Bitumen Blue Roof Vertical Outlet DN70: Insulated internal outlet. To be used in conjunction with Bauder Bitumen Blue Roof Flow Restrictor only. Bauder Bitumen Blue Roof Vertical Outlet DN70 (when used with Bauder Bitumen Blue Roof Flow Restrictor) flow rates are project specific and obtained via Bauder Technical.
  • BauderBLUE ST-B Adjustable Blue Roof Flow Restrictor – Bitumen. The BauderBLUE ST-B Adjustable Blue Roof Flow Restrictor – Bitumen is designed to be used in conjunction with a standard Bauder Bitumen Blue Roof Vertical Outlet DN70. The Bauder Blue Roof Bitumen Flow Restrictor is comprised of four parts; Baseplate, overflow pipe, Baseplate inner and Baseplate outer seal. The polyamide Baseplate fits within the 70 mm vertical outlet, with the EPDM outer seal creating a watertight fit. The PE-HD Overflow slots into the central hole of the Baseplate with an inner EPDM seal preventing any leaks. BauderBLUE ST-B Adjustable Blue Roof Flow Restrictor – Bitumen must be set to the requirement of the particular roof. Bauder must be consulted to carry out this bespoke design.
  • Bauder Parapet Emergency Overflow Stainless Steel DN70: Emergency overflow/ tell-tale.

Bauder rooflights/ glazing/ ventilation.

Guidance for specification option:

All these glazing products are fully compatible with the roof waterproofing systems. Consult manufacturer for details and insert requirements.

  • BauderDOME Rooflight.
  • Bauder Euroglaze Rooflight.
  • Bauder Special Modular Rooflight.
  • Bauder Continuous Rooflight.
  • Bauder Walk-on Rooflight.
  • Bauder Direct Glazing.
  • Bauder AOV.
  • Bauder Modular Link Glazing.
  • Bauder Structural Rooflight.
  • Bauder Fire Rated Rooflight.

Sustainability data

Third party certifications

Third party certifications

EPD

EPD

Environmental Product Declaration - RBM

BBA Agrément Certificate

BBA Agrément Certificate

Certificate: Bauder Total Green Roof Systems 10/4744

CCPI System

CCPI System

Bauder BTRS-BTGRS CCPI System Certificate

Similar products from Bauder Ltd

Bauder System Airtech Cold Roof System - Self Adhered

Bauder System Airtech Cold Roof System - Self Adhered

Bauder Total Green Roof System PLUS Reinforced Bitumen Membrane Cold Roof Covering System Self-Adhered (with Torch-On Capping Sheet).

Bauder Total Green Roof System PLUS Reinforced Bitumen Membrane Cold Roof Covering System Self-Adhered (with Torch-On Capping Sheet).

Bauder Total Roof System PLUS Reinforced Bitumen Membrane Cold Roof Covering System Self-Adhered (with Torch-On Capping Sheet)

Bauder Total Roof System PLUS Reinforced Bitumen Membrane Cold Roof Covering System Self-Adhered (with Torch-On Capping Sheet)

Bauder Total Roof System Reinforced Bitumen Membrane Cold Roof Covering System Self-Adhered (with Torch-On Capping Sheet)

Bauder Total Roof System Reinforced Bitumen Membrane Cold Roof Covering System Self-Adhered (with Torch-On Capping Sheet)

Bauderflex Green Reinforced Bitumen Membrane Cold Roof System - Self Adhered (with Torch-On Capping Sheet).

Bauderflex Green Reinforced Bitumen Membrane Cold Roof System - Self Adhered (with Torch-On Capping Sheet).

Bauderflex Reinforced Bitumen Membrane Cold Roof Covering System Self-Adhered (with Torch-On Capping Sheet)

Bauderflex Reinforced Bitumen Membrane Cold Roof Covering System Self-Adhered (with Torch-On Capping Sheet)