Verified by manufacturer 6 days ago
CCPI System
Certificate type
BBA Agrément Certificate
Certificate type
EPD
Certificate type
Bitumen cold roof system, incorporating torch-on bitumen root resistant capping sheet with self-adhered bitumen underlayer.
Suitable for a variety of applications on both new build and refurbishment projects and can be used in cold and inverted roof scenarios.
Bitumen cold roof system, incorporating torch-on bitumen root resistant capping sheet with self-adhered bitumen underlayer, suitable for a variety of applications on both new build and refurbishment projects, and can be used in warm, cold and inverted roof scenarios.
Plus Points:
Assessments and verifications:
Color | Green |
Finish | Mineral |
Material | Bitumen |
Shape | Square Rectangle |
Length | Bespoke |
Width | Bespoke |
Warranty description | Manufacturer guidanceGuarantee options could include ‘Product’, ‘Product and Workmanship’ and ‘Product, Workmanship and Design’ guarantees. All guarantees available for this system are subject to the works being carried out in accordance with the Bauder specification and being installed by a Bauder Approved Installer. For full details and further information regarding guarantees and alternative systems please contact a local Bauder Representative or technical@bauder.co.uk. |
Uniclass | |
CAWS | J41/130 Built-up reinforced bitumen membrane cold deck roof covering J41/12 Reinforced bitumen membrane cold deck roof covering |
Preparation | |
Horizontal work | Activator-Primer (Canister) APR01 - Black.Guidance for specification option: Synthetic rubber resin-based primer, developed to provide the necessary preparation of substrates prior to the installation of self-adhesive and torch-applied membranes. The spray application offers improved film thickness speed of application (by up to 50% over roller applied products) and quick drying in a matter of minutes.
SA Bonding Primer.Guidance for specification option: For Self-Adhesive membranes to Concrete and Screeded Substrates. Synthetic rubber-based primer, specially formulated to increase the bond strength of Bauder self-adhesive bitumen membranes to a wide range of substrates, including timber, concrete, brick, metal and most plastics.
Manufacturer guidanceContact manufacturer to confirm substrate suitability if required. |
Skirtings and vertical work | As 'Horizontal work'. |
Waterproof covering | |
First layer | |
Type | BauderTEC Sprint DUO.Guidance for specification option: Elastomer bitumen self-adhesive underlayer with variable technology for lap sealing. The two side laps of the membrane have differing finishes. On one lap there is a self-adhesive finish, whist the opposite lap has a glass fleece. This allows the membrane to be sealed with either a gas torch or hot air welder.
Manufacturer guidanceTo be fully specified separately. |
Attachment | Self-adhered. |
Top layer | |
Type | BauderPLANT E 42.Guidance for specification option: Elastomer-bitumen torch on capping sheet with root-resistance according to FLL. The product features a spunbond polyester reinforcement to allow the finished product to cope with structural movement without fracture.
|
Attachment | Torch applied. |
Detail work | |
Flashings | Bauder GRP Trim.Guidance for specification option: GRP roof edge trim for use with Bauder bituminous roof systems. Available colours of either grey or black and a choice of profiles to suit the requirements of most projects. Bauder GRP Water Check Trim.Guidance for specification option: GRP water check trim to be used on parapets and perimeter kerbs wider than 200 mm – must not be used on its own as a check kerb. Available in black only. Bauder Aluminium Termination Bar.Guidance for specification option: Natural finish aluminium alternative to a lead counterflashing for use at upstand details to give protection to the top edge of the waterproofing. It should be restricted to use on upstands where a chase cannot be cut into the wall. Bauder GRP Termination Bar.Guidance for specification option: Black glass-reinforced plastic (GRP) alternative to a lead counterflashing for use at upstand details to give protection to the top edge of the waterproofing. It should be restricted to use on upstands where a chase cannot be cut into the wall. |
Skirtings and upstands | Bauder LiquiFIBRE Detailing Kit.Guidance for specification option: Fast-curing waterproofing resin containing fibre reinforcement that can be used for detailing awkward shapes or inaccessible areas where using LiquiDETAIL is impractical. PMMA-based resin that requires a catalyst and is solvent-free, isocyanate-free and halogen-free. Bauder LiquiDETAIL.Guidance for specification option: Cold liquid-applied fast-curing waterproofing resin that can be used on upstands and details. PMMA-based resin that requires the addition of catalyst to trigger curing and is solvent-free, isocyanate-free and halogen-free. Not required. |
Welted drips | Required.Guidance for specification option: Insert requirements. Not required. |
Cover strips | Required.Guidance for specification option: Insert requirements. Not required. |
Ancillary items | Required.Guidance for specification option: Insert requirements. Not required. |
Surface protection | Not required. |
System accessories | Not required.Bauder lightning conductors.Guidance for specification option: Lightning conductor clips are a specially designed secure clip that allows for movement.
Bauder rainwater outlets.Guidance for specification option: Bauder has a range of insulated or stainless-steel rainwater outlets. The insulated outlets can be used for maintaining thermal continuity at drainage points. Suitable for warm, cold and inverted roof construction. The BRE Certified (report no. HPR357-303748) high thermal value of the rigid foam body prevents condensation from forming on the underside of the outlet body. Designed for use when connecting to conventional drainage systems and is suitable for both new build and refurbishment projects. Outlets are included in the Bauder waterproofing system guarantee as they are integrated components. Flow rate figures (where applicable) are based on BS EN 12056:3:2000, typically taken using a 35 mm header of water including leaf grille:
Bauder rooflights/ glazing/ ventilation.Guidance for specification option: All these glazing products are fully compatible with the roof waterproofing systems. Consult manufacturer for details and insert requirements.
|
Surfacing layer | Not required. Landscaping options. Guidance for specification option: Refer to Bauder Extensive / Biodiverse / Intensive Landscaping systems and insert details. |
Contains Red List materials | No |
Material | Bitumen |
Bauder System Airtech Cold Roof System - Self Adhered
Bauder Total Green Roof System PLUS Reinforced Bitumen Membrane Cold Roof Covering System Self-Adhered (with Torch-On Capping Sheet).
Bauder Total Green Roof System Reinforced Bitumen Membrane Cold Roof Covering System Self-Adhered (with Torch-On Capping Sheet)
Bauder Total Roof System PLUS Reinforced Bitumen Membrane Cold Roof Covering System Self-Adhered (with Torch-On Capping Sheet)
Bauder Total Roof System Reinforced Bitumen Membrane Cold Roof Covering System Self-Adhered (with Torch-On Capping Sheet)
Bauderflex Reinforced Bitumen Membrane Cold Roof Covering System Self-Adhered (with Torch-On Capping Sheet)