NBS Source
I'm a manufacturer

Application

For use on flat roofs. Suited to projects where the main criteria is to meet a tight budget.

Description

Waterproofing solutions for flat roofs.


Features and benefits:

  • Tested to CEN/TS 1187 at WarringtonFire, achieving a fire rating of Broof (T4).
  • High quality and competitively priced range of SBS modified, high performance torch-on membranes.
  • The fully modified bitumen used in their production benefits the contractor with an easy and secure product to install.
  • A high bond strength and greater resistance to breakdown results in a lasting roofing.
  • Weighs 5 kg/m² (3 mm-thick underlay).
  • CE marked.


Also available as a cold roof system (specified separately), Classic and Classic Plus (non-fire-rated) systems are also available; consult manufacturer for details.

General information

Color

Black

Guidance for specification option:

Charcoal.

Finish

Mineral

Material

Bitumen

Shape

Rectangle

Size

Guidance for specification option:

1 m-wide roll.

Length

8000 mm

Width

1000 mm

Height

4.5 mm

Warranty description

20 year

Guidance for specification option:

Bailey Classic range of systems are covered by a simple and easy to use, self-issue guarantee. The manufacturer’s guarantee certificate comes in two parts; consult manufacturer for details.

Uniclass

Ss_30_40_30_72 Reinforced bitumen membrane warm roof covering systemsPrimary

CAWS

J41/110 Built-up reinforced bitumen membrane warm deck roof covering

J41/10 Reinforced bitumen membrane warm deck roof covering

Product range

Flat Roofing Systems / Bitumen Felt

Specification data - Reinforced bitumen membrane warm roof covering systems

Preparation

-

Horizontal work

Bailey self-adhesive membrane primer.

Guidance for specification option:

22 L cannister.

Bailey AMC high penetration bitumen primer.

Guidance for specification option:

25 L drum.

Skirtings and vertical work

Bailey self-adhesive membrane primer.

Guidance for specification option:

22 L cannister.

Bailey AMC high penetration bitumen primer.

Guidance for specification option:

25 L drum.

Air and vapour control layer

-

Type

Bailey Alpha-Bar aluminium cored-bitumen self-adhesive vapour barrier.

Bailey Alpha-Bar aluminium cored-bitumen torch-on vapour barrier.

Attachment

Self-adhered.

Guidance for specification option:

Bailey Alpha-Bar aluminium cored-bitumen self-adhesive vapour barrier only.

Gas torch application.

Guidance for specification option:

Bailey Alpha-Bar aluminium cored-bitumen torch-on vapour barrier only.

Insulation

-

Type

Bailey Sure-Therm PIR bitumen-faced flat board insulation, __ mm.

Guidance for specification option:

Insert requirements.

Bailey Sure-Therm PIR bitumen-faced tapered insulation scheme, __ falls.

Guidance for specification option:

Insert requirements; .standard falls: 1:80, 1:60, 1:40.

Non-standard falls available.

Bailey Sure-Therm PIR glass tissue-faced flat board insulation, __ mm.

Guidance for specification option:

Insert requirements.

Bailey Sure-Therm PIR glass tissue-faced tapered insulation scheme, __ falls.

Guidance for specification option:

Insert requirements; .standard falls: 1:80, 1:60, 1:40.

Non-standard falls available.

Bailey Sure-Therm non-combustible mineral wool flat board, __ mm.

Guidance for specification option:

Insert requirements.

Bailey Sure-Therm non-combustible mineral wool tapered insulation scheme, __ falls..

Guidance for specification option:

Insert requirements; .standard falls: 1:80, 1:60, 1:40.

Non-standard falls available.

Fixing

Bonding with hot bitumen.

Sure-Bond PU insulation adhesive.

Bailey Sure-Fix insulation tube washers, Bailey Sure-Fix steel deck fixings.

Guidance for specification option:

To required length.

Bailey Sure-Fix insulation tube washers, Bailey Sure-Fix timber deck fixings.

Guidance for specification option:

To required length.

Bailey Sure-Fix insulation tube washers, Bailey Sure-Fix concrete deck fixings.

Guidance for specification option:

To required length.

Waterproof covering

-

First layer

-

Type

Bailey Alpha-Vent perforated venting layer.

Guidance for specification option:

Only necessary if using a standard torch-on underlay.

Not required.

Guidance for specification option:

If specifying Bailey Classic 3 mm venting underlay as the intermediate layer.

Attachment

Loose-laid.

Guidance for specification option:

Bailey Alpha-Vent perforated venting layer only.

Not applicable.

Guidance for specification option:

If specifying Bailey Classic 3 mm venting underlay as the intermediate layer.

Intermediate layer

-

Type

Bailey Classic 3 mm torch-on underlay.

Bailey Classic 3 mm venting underlay.

Guidance for specification option:

No perforated (top) layer needed.

Attachment

Torch-on.

Top layer

-

Type

Bailey Classic Plus FR torch-on mineral capsheet.

Attachment

Torch-on.

Detail work

-

Flashings

Bailey Classic 3 mm underlay and Classic Plus FR torch-on mineral capsheet.

Skirtings and upstands

Bailey Classic 3 mm underlay and Classic Plus FR torch-on mineral capsheet.

Welted drips

Bailey Classic Plus FR torch-on mineral capsheet.

Cover strips

Bailey Classic Plus FR torch-on mineral capsheet.

Surface protection

Bailey 300 g/m² geotextile protection fleece.

System accessories

Not required.

Outlets - specified below.

Guidance for specification option:

See 'Outlets' for details.

Bailey Sure-flow stainless steel leaf guard - F-631-L.

Bailey Sure-flow stainless steel parapet leaf guard - F-632-LP.

Bailey Sure-flow stainless steel cylindrical leaf guard - F-633-LC.

Bailey Sure-flow stainless steel balcony leaf guard - F-634-LB.

Bailey Flow-therm standard retaining unit - 25–105 mm - F-652-25/105.

Bailey Flow-therm parapet leaf guard - 110 mm - F-663-110.

Bailey Flow-therm parapet leaf guard - 75 mm - F-663-75.

Bailey Flow-therm parapet connecting pipe - 110 mm - F-664-110.

Bailey Flow-therm parapet connecting pipe - 75 mm - F-664-75.

Outlets

Bailey Sure-flow stainless steel outlet - 40 mm (felt flange) - F-630–40.

Bailey Sure-flow stainless steel outlet - 50 mm (felt flange) - F-630–50.

Bailey Sure-flow stainless steel outlet - 62 mm (felt flange) - F-630–62.

Bailey Sure-flow stainless steel outlet - 70 mm (felt flange) - F-630–70.

Bailey Sure-flow stainless steel outlet - 75 mm (felt flange) - F-630–75.

Show more

Sustainability data

Contains Red List materials

No

Similar products from Bailey - Total Building Envelope

Bailey System 17000 FR (Warm Roof)

Bailey System 17000 FR (Warm Roof)

Bailey System 5000 FR Self-Adhesive (Warm Roof)

Bailey System 5000 FR Self-Adhesive (Warm Roof)