Verified by manufacturer 5 months ago
TB400
Touch Bar Panic Latch.
Suitable for wooden or steel doors including fire doors.
Surface mounted touch bar panic latches for wooden or steel, single and double door applications. The 400 is suitable for doors up to 900 mm wide and the 401 for doors up to 1200 mm wide.
Pushing the touch bar provides safe and speedy exit in panic situations, whilst the patented lip prevents accidental jamming.
Features and benefits:
Color | Silver Guidance for specification option: Stainless steel. White Black |
Material | Steel Aluminium |
Shape | Rectangle |
Warranty description | Ten year |
Uniclass | |
CAWS | P21/32 Panic exit devices P21/30 Emergency exit devices P21/577 Panic exit devices P21/571 Emergency exit devices |
Standard | To BS EN 1125. |
Classification grades (minimum) | |
Category of use | To BS EN 1125, grade 3. |
Durability | To BS EN 1125, grade 7. |
Door mass | To BS EN 1125, grade 6. |
Suitability for use on fire and smoke doors | To BS EN 1125, grade 1. |
Safety | To BS EN 1125, grade 1. |
Corrosion resistance | To BS EN 1125, grade 3. |
Security | To BS EN 1125, grade 2. |
Projection of bar | To BS EN 1125, grade 2. |
Type of bar operation | To BS EN 1125, grade B. |
Field of door application | To BS EN 1125, grade A. |
Material and finish | Powder coated.Plated. |
Colour | Custom.Guidance for specification option: All RAL. Stainless steel.Guidance for specification option: Silver. White.Black. |
Execution | Fasteners for hardware |
Accessories | 409 Outside access device – knob operated. 410EC Outside access device with Euro cylinder – lever operated. 410EA Outside access device with Euro aperture – lever operated. 410OC Outside access device with oval cylinder – lever operated. 410OA Outside access device with oval aperture – lever operated. |
Door width | Up to 900 mm. |
Contains Red List materials | No |
Country of product manufacture | United Kingdom |
Recyclability | 90% Manufacturer guidanceMetals widely recycled. |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 60 % |