Aspirating smoke detector providing very early warning for small business-critical environments.

Jump to:
+44 (0) 203 409 1779 Website

Application

Suitable for a range of application areas, for example:

  • Local telecommunication exchanges.
  • Air handling units.
  • Smaller server rooms.
  • Correctional facilities.
  • Control rooms.
  • Utility control hubs.
  • Switch rooms.
  • Railway signal hubs.
  • Storage facilities.
  • Cabinets.
  • Hazardous areas (Class 1 Division 2).
  • Substations.

Description

Aspirating smoke detector providing very early warning for small business-critical environments.

This configuration protects environments of less than 250 m² (VLF-250-00), or 500 m² (VLF-500-00). The detector works by continually drawing air into sampling holes in a pipe network. The air is filtered and passed into a detection chamber where light scattering technology detects the presence of very small amounts of smoke. Detector status information is communicated on the detector display and via relays or optional interface cards.

Features and benefits:

  • Out-of-the-box installation and commissioning.
  • Ultrasonic airflow sensing.
  • Laser-based absolute smoke detection.
  • Sensitivity range - 0.025 - 20.00% obs/m
  • Pre-engineered pipe network designs.
  • Programmable alarm thresholds.
  • Clean air barrier optics protection.
  • Instant recognition display.
  • Instant Fault Finder™.
  • AutoLearn™ Smoke.
  • AutoLearn™ Flow.
  • Field service access door.
  • Multiple event logging in separate logs.
  • Event log – up to 18 000 events.
  • Offline/ online configuration capability.
  • Up to 250 m² (VLF-250-00) or 500 m² (VLF-500-00) coverage.
  • Suitable for upright, inverted or horizontal mounting.
  • CE/ UKCA Certified.

General information

Color

White

Material

Plastic

Shape

Rectangle

Length

92 mm

Manufacturer guidance

Depth.

Width

256 mm

Height

183 mm

Uniclass

Pr_75_80_30_03 Aspirating smoke detectorsPrimary

CAWS

W90/328 Point smoke detectors

SKU Code

VLF-250-00

Specification data - Aspirating smoke detectors

Classification data

Standard

To BS EN 54-20.

Guidance for specification option:

& ISO 7240-20.

Third-party certification

LPCB, FM, ActivFire, VdS, NF, and CCC-approved.

Sensitivity class

To BS EN 54-20, Class A.

Guidance for specification option:

VLF-250-00: 12 holes / 0.12% obs/m.

VLF-500-00: 30 holes / 0.05% obs/m.

To BS EN 54-20, Class B.

Guidance for specification option:

VLF-250-00: 12 holes / 0.35% obs/m.

VLF-500-00: 30 holes / 0.15% obs/m.

To BS EN 54-20, Class C.

Guidance for specification option:

VLF-250-00: 12 holes / 0.80% obs/m.

VLF-500-00: 30 holes / 0.32% obs/m.

Sampling pipe

-

Arrangement

-

Manufacturer guidance

Accepts both metric and American standard size pipes. Metric: 25 mm.

Consult manufacturer and insert requirements.

Length (maximum)

25 m.

Air inlet holes (maximum)

12.

Guidance for specification option:

For all classes.

Pre-engineered option, consult manufacturer for alternatives.

Coverage (minimum)

250 m².

Enclosure

-

Material

Plastic.

Ingress protection (minimum)

IP 30.

Power supply

24 V d.c.

Controls

-

Display type

Light-emitting diode display (LED).

Guidance for specification option:

Smoke dial LED.

3.5” display.

Functions

Four alarm thresholds (two pre-alarms and two alarms).
On board memory capable of recording 18 000 events.

Guidance for specification option:

Event log: Up to 18 000 events, time and date stamped in separate, non-volatile, logs.

Smoke level, flow level, detector status and faults.

Display the following information

Alert, Action, Fire 1 and Fire 2.
Visual indication of smoke level.
Reset, disable and test control.
Disabled.
Fault.
Power.
Flow AutoLearn™ Controls.

Guidance for specification option:

Threshold setting range:

  • Alert, Action: 0.025 to 2.00% obs/m.
  • Fire 1, Fire 2: 0.025 to 20.00% obs/m.
  • Individual alarm delays: 0–60 seconds.
  • Two alarm threshold settings: Either time or GPI based.

Relay contacts

3 no. 2 A/ 30 V d.c. changeover relays.

Guidance for specification option:

Fire (NO), Fault (NC) contacts.

Weight

2 kg.

Power consumption

Manufacturer's standard.

Operating temperature

Ambient: 0–38°C.
Sampled air: -20 to +60°C.

Operating humidity

5–95% RH, non-condensing.

SoftwareVersion

N/A - out-of-the-box.

Sensitivity

Manufacturer's standard.

Cable

3 x 25 mm cable entries.

Guidance for specification option:

Cable terminations: Screw terminal blocks.

Communications

VESDAnet.

Accessories

Not required.
Power supply unit - VPS-220-E5.

Guidance for specification option:

This is the original unit within the range. Internally is an EN 54-4 certified Power Supply rated to provide a 0.5 A continuous 24 V d.c. supply while also charging the batteries (not supplied) which can be a 7, 12 or uniquely, 14 Ah arrangement. As such the unit can be used with confidence to power, and provide 24 hr standby (plus 0.5 hr in alarm), for the VESDA detectors.

Power supply unit - VPS-215-E5.

Guidance for specification option:

This is the budget unit within the range. It is intended as a low-cost unit to supply a single pipe ASD detector which only requires 7 Ah batteries such as the VESDA VLF-250. A simple but elegant construction and no LEDs on the lid keep the cost of the unit to a minimum. The unit can also be inverted where necessary by rotating the lid. The internal charger is EN 54-4 certified and internal LEDs are provided to indicate OK (output healthy) and Fault.

Power supply unit - VPS-250-E5.

Guidance for specification option:

This power supply is capable of powering larger ASD units. It may also be used for installations with multiple detectors and/ or remote displays. The internal charger is EN 54-4 certified to power loads up to 3 A with space and charging capacity for batteries up to 38 Ah. Uniquely, the unit is supplied with the provision to deliver 4 separately fused outputs – recommended when it is used to power multiple detectors or disparate loads.

VESDAnet Interface Card - VIC-010.
Multifunction Control Card (MCC) - VIC-020.
Multifunction Control Card (MCC) with Monitored Powered Output (MPO) - VIC-030.
Filter Cartridge - VSP-005.
Xtralis In-Line Filter.
Aspirator for VESDA VLF-250 - VSP-722.
ASD Sampling Hole Clips.
Refrigerated Storage Sampling Kit - VSP-860.
Tamper Proof Sampling Point.
Automatic Purging Unit - F-BO-AFE70.
VESDA High Level Interface (HLI).
VESDA Remote Display Module.
VESDA 19" Sub Rack.
VESDA LCD Programmer.
Xtralis Test Transformer.
Smoke Pen.

Manufacturer guidance

Spare parts are also available - consult manufacturer for details.

Sustainability data

Material

Plastic

Similar products from XTRALIS

Addressable Aspirating Smoke Detector - VESDA-E VEA - Aspirating Smoke Detector

Addressable Aspirating Smoke Detector - VESDA-E VEA - Aspirating Smoke Detector

Aspirating Smoke Detection - VESDA-E VES - Aspirating Smoke Detector

Aspirating Smoke Detection - VESDA-E VES - Aspirating Smoke Detector

Aspirating Smoke Detector - VESDA Laser Industrial (VLI) - Aspirating Smoke Detector

Aspirating Smoke Detector - VESDA Laser Industrial (VLI) - Aspirating Smoke Detector

Aspirating Smoke Detector - VESDA-E VEP - Aspirating Smoke Detector

Aspirating Smoke Detector - VESDA-E VEP - Aspirating Smoke Detector

Aspirating Smoke Detector - VESDA-E VEU - Aspirating Smoke Detector

Aspirating Smoke Detector - VESDA-E VEU - Aspirating Smoke Detector

FAAST FLEX™ - Aspirating Smoke Detector - Aspirating Smoke Detector

FAAST FLEX™ - Aspirating Smoke Detector - Aspirating Smoke Detector