Cavity fixed clay brick slip external wall insulation (EWI) system.

Jump to:
01183 240 130 Website

Application

External walls.

Description

The AlivaBrick M system consists of mineral wool insulation boards which are mechanically fixed to steel top hat rails, which are mechanically fixed into the sheathed lightweight steel frame supporting wall. A layer of basecoat with reinforcement mesh is applied to the mechanically fixed insulation boards and the finishes applied. The system is finished with a clay brick slip by embedding the slips into a cementitious bedding mortar and finished with a cement pointing grout.

Features and benefits:

  • Directly fixed with mechanical fixings via 15 mm steel ‘top hat’ channel to create cavity.
  • Finished with a clay brick slip from 9–25 mm thickness.
  • Class A1 fire classification to BS EN 13501-1:2019 (surface spread of flame).
  • The system when installed to specification will achieve a design life of in excess of 30 years.
  • KIWA BDA certified.

Approved substrates:

Lightweight steel frames with cement or calcium silicate sheathing boards.

General information

Color

Other

Finish

Brick

Material

Clay

Mineral wool

Shape

Other

Length

Bespoke

Width

Bespoke

Height

Bespoke

Warranty description

Ten year

Uniclass

Ss_25_45_72_28 External wall insulation systemsPrimary

CAWS

M21/210 Rendered external wall insulation systems

M21/20 External wall insulation systems

Specification data - External wall insulation systems

Description

Cavity fixed external wall insulation (EWI) brick slip system.

System manufacturer

Aliva UK Ltd.

Support rails and brackets

-

Fixing method

-

Material

Steel top hat rails.

Bracket fixings

Mechanically fixed.

Guidance for specification option:

Consult manufacturer for details.

Boards

-

Material

12 mm sheathing board (cement particle board).

Fixings

-

Manufacturer guidance

Consult manufacturer for details and insert requirements or omit.

Insulation

-

Material

Mineral wool insulation boards.

Additional mechanical fixings

Mechanical fixing.

Guidance for specification option:

Consult manufacturer for details.

Render carrier or reinforcement

-

Material

Reinforcing mesh.

Mesh size

-

Manufacturer guidance

Consult manufacturer for details.

Fixings

Mechanical fixing through pinning mesh.

Guidance for specification option:

Consult manufacturer for details.

Render

-

Application

Base coat.

Material

Cementitious renders.

Decorative finish

Clay brick slips, 9–25 mm thick, finished with a cement pointing grout.

Guidance for specification option:

Fixed to clay slip adhesive layer.

Colour

-

Manufacturer guidance

Consult manufacturer for details and insert requirements.

Fire classification

Class A1 to BS EN 13501-1 (surface spread of flame).

Sustainability data

Material

Clay
Mineral wool

Expected Life

30 year

Guidance for specification option:

The system when installed to specification will achieve a design life of in excess of 30 years.

Literature

AlivaBrick M - Cavity Fixed

AlivaBrick M - Cavity Fixed

Similar products from Aliva UK Ltd

AlivaBrick E - Direct Fixed - External Wall Insulation / ETICS System

AlivaBrick E - Direct Fixed - External Wall Insulation / ETICS System

AlivaBrick M - Direct Fixed

AlivaBrick M - Direct Fixed

AlivaCeramic E - Direct Fixed - External Wall Insulation / ETICS System

AlivaCeramic E - Direct Fixed - External Wall Insulation / ETICS System

AlivaCeramic M - Cavity Fixed - External Wall Insulation / ETICS System

AlivaCeramic M - Cavity Fixed - External Wall Insulation / ETICS System

AlivaCeramic M - Direct Fixed - External Wall Insulation / ETICS System

AlivaCeramic M - Direct Fixed - External Wall Insulation / ETICS System

AlivaClassic E - Direct Fixed - External Wall Insulation / ETICS System

AlivaClassic E - Direct Fixed - External Wall Insulation / ETICS System

AlivaClassic M - Cavity Fixed - External Wall Insulation / ETICS System

AlivaClassic M - Cavity Fixed - External Wall Insulation / ETICS System

AlivaClassic M - Direct Fixed - External Wall Insulation / ETICS System

AlivaClassic M - Direct Fixed - External Wall Insulation / ETICS System

AlivaDesign E - Direct Fixed - External Wall Insulation / ETICS System

AlivaDesign E - Direct Fixed - External Wall Insulation / ETICS System

AlivaDesign M - Cavity Fixed - External Wall Insulation / ETICS System

AlivaDesign M - Cavity Fixed - External Wall Insulation / ETICS System